www.lorentz.de, version 070402. Errors excepted and possible alterations without prior notice 1
ETATRACK
®
active
Installation of Controller
and Motor
1 Function of the ETATRACK active Controller
The tracker controller calculates the duration
of the days based on the output voltages of
the solar-modules – disconnecting the solar-
array will result in wrong daytime calcula-
tions! Parallel operation of tracker control-
ler with battery charger or Inverter can
cause wrong tracking movements. An
additional small PV-Module should be used
for such applications: Min. 5 Wp for locations
between 45°North and 45° South, min. 10Wp
for locations ‡45°North or South for the
tracker power supply. Only the total electrical
separation between tracker controller and
battery charger / inverter ensures perfect
operation. LORENTZ PS Pump Controllers
do not require the additional PV-Modul
First connect the motor power cable and the motor reed
switch, then connect battery and the solar module to the
controller terminals. The solar module is used for Day /
Night-detection.
Set the jumper to northern or southern hemisphere.
Now the motor can be moved manually in small steps by
pushing the East or the West button
Press the Manual button to initialize the controller.
After that the controller will start the tracking automatical-
ly.
First it will move some degrees to West direction (not with
the jumper setting to “Southern Hemisphere” as the frame
is already in West position). Then it will move (back) into
East direction.
After reaching the final East position it will start to move
to the final West position and then back to »High Noon«
position. That is a learning process for the controller. The
rest of the first day will be handled as a standard day.
In case reverse action is determined the two
motor cables has to be reversed!
Disconnect and reconnect the battery and the
solar module in order to make a controller
reset and the learning process will start
again.
During the night the tracker moves into »High Noon«
position. After the first night the tracking will fit the real
duration of the next day.
Overload protection:
The tracker controller has an integrated overload protec-
tion: After an overload occurred the controller stops the
motor, the Overload LED goes On (Power LED goes Off)
Only disconnecting power can reset the overload ( battery
and solar). Before resetting please check the mechanical
conditions: Try to find out where the tracking frame or the
motor is blocked and check the whole assembly for
smooth movement.
Polarity protection solar input:
In case of wrong polarity connection of the solar modules
to the tracker electronics, no damage will occur.
Correct the wiring
Polarity protection battery input:
In case of wrong polarity connection of the battery, the
fuse will blow.
Correct the wiring and replace the fuse.
Power consumption:
Max. 1,25 kWh per year
Trouble shooting:
Check all cables and the fuse first.
In case of a low battery voltage (11V) the controller shuts
the system off and moves the tracker to high noon posi-
tion. It can be still moved manually with the east and
West buttons.
Once the voltage of the battery has reached 12,5V the
tracker will start again to follow the sun.
Check if the tracker can move easily. Disconnect the
motor if needed and control by hand the easy movement.
www.lorentz.de, version 070402. Errors excepted and possible alterations without prior notice 2
NOTE: Wrong wiring of tracker
motor and reed sensor will
destroy electronic components!
2 Operation, Monitoring and Wiring
The Overload LED will go ON and the Power LED will go
OFF after an overload occurred.
Reset by disconnecting battery and solar power
LED flashes when battery is low
LED flashes quickly while the tracker is moving
LED flashes slowly in automatic mode
LED will be always ON in manual mode
Select Northern or Southern Hemisphere with the
jumper (factory setting: northern hemisphere-no jum-
per required)
Pushing this button will move the tracker by one
step to west direction (Manual Mode)
Pushing this button will move the tracker by one
step to east direction (Manual Mode)
Pushing this button will switch the controller from
AUTOMATIC to MANUAL mode (only when the
tracker is not moving!)
Pushing again will switch back to AUTO mode
Connect to the battery. Take care for right polarity !
Connect to the PV-array (Max. 200 Voc, at least no-
minal 12 V). Take care for the right polarity !
Motor housing / Connection Box
Motor B
M
oto
r A
Motor reed switch
www.lorentz.de, version 070402. Errors excepted and possible alterations without prior notice 3
Pum
p
Controller
Wiring Diagram Controller ETATRACK active
(
included in controller box
)
Wiring diagram Controller ETATRACK active
for applications
with LORENTZ PS Pump Systems
www.lorentz.de, version 070402. Errors excepted and possible alterations without prior notice 4
Wiring diagram Controller ETATRACK active
for applications with ON-Grid inverters or
battery chargers
(included in controller box)

Other Lorentz Inverter manuals

Lorentz LA Series User manual

Lorentz

Lorentz LA Series User manual

Lorentz PSk3-7 Specification sheet

Lorentz

Lorentz PSk3-7 Specification sheet

Popular Inverter manuals by other brands

COMPANION 919.327210 General manual

COMPANION

COMPANION 919.327210 General manual

Westerbeke 3.8 BCDT-612 Specifications

Westerbeke

Westerbeke 3.8 BCDT-612 Specifications

Fairchild FSAM50SM60A manual

Fairchild

Fairchild FSAM50SM60A manual

Xantrex Trace Series installation instructions

Xantrex

Xantrex Trace Series installation instructions

MARIMEX SLIM 3000 Operational manual

MARIMEX

MARIMEX SLIM 3000 Operational manual

Ecoer EG910L Quick start up guide

Ecoer

Ecoer EG910L Quick start up guide

Uniteck UNIPOWER 800.12 PRO instruction manual

Uniteck

Uniteck UNIPOWER 800.12 PRO instruction manual

SMA SUNNY BOY3000TL-US installation manual

SMA

SMA SUNNY BOY3000TL-US installation manual

Huawei SDongleA-01 user manual

Huawei

Huawei SDongleA-01 user manual

Sanken SAMCO-NS Series instruction manual

Sanken

Sanken SAMCO-NS Series instruction manual

Toshiba TOSVERT VF-AS1 Series instruction manual

Toshiba

Toshiba TOSVERT VF-AS1 Series instruction manual

HYXIPOWER M300-SW user manual

HYXIPOWER

HYXIPOWER M300-SW user manual

SMA SUNNY ISLAND 3.0M operating manual

SMA

SMA SUNNY ISLAND 3.0M operating manual

ABB ACS 400 installation guide

ABB

ABB ACS 400 installation guide

Streetwize SWINV500 user manual

Streetwize

Streetwize SWINV500 user manual

Stanley Pc100 instruction manual

Stanley

Stanley Pc100 instruction manual

Huawei MERC Series user manual

Huawei

Huawei MERC Series user manual

RIB EMPS375 Installation and operation instruction

RIB

RIB EMPS375 Installation and operation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.