manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lovibond
  6. •
  7. Measuring Instrument
  8. •
  9. Lovibond SD 90 User manual

Lovibond SD 90 User manual

Other Lovibond Measuring Instrument manuals

Lovibond LC 100 User manual

Lovibond

Lovibond LC 100 User manual

Lovibond Tintometer SensoDirect Con110 User manual

Lovibond

Lovibond Tintometer SensoDirect Con110 User manual

Lovibond RT 400 User manual

Lovibond

Lovibond RT 400 User manual

Lovibond SD 60 REDOX User manual

Lovibond

Lovibond SD 60 REDOX User manual

Lovibond SensoDirect pH110 User manual

Lovibond

Lovibond SensoDirect pH110 User manual

Lovibond MicroDirect pH10 User manual

Lovibond

Lovibond MicroDirect pH10 User manual

Lovibond MD200 User manual

Lovibond

Lovibond MD200 User manual

Lovibond Tintometer SensoDirect Salt110 User manual

Lovibond

Lovibond Tintometer SensoDirect Salt110 User manual

Lovibond Tintometer SensoDirect Salt110 User manual

Lovibond

Lovibond Tintometer SensoDirect Salt110 User manual

Lovibond Tintometer MD100 User manual

Lovibond

Lovibond Tintometer MD100 User manual

Lovibond TG 60/268 Assembly instructions

Lovibond

Lovibond TG 60/268 Assembly instructions

Lovibond MD200 User manual

Lovibond

Lovibond MD200 User manual

Lovibond SD 400 Oxi L User manual

Lovibond

Lovibond SD 400 Oxi L User manual

Lovibond Scuba User manual

Lovibond

Lovibond Scuba User manual

Lovibond SD 60 User manual

Lovibond

Lovibond SD 60 User manual

Lovibond Photometer-System MD100 User manual

Lovibond

Lovibond Photometer-System MD100 User manual

Lovibond MD200 User manual

Lovibond

Lovibond MD200 User manual

Lovibond Fx Assembly instructions

Lovibond

Lovibond Fx Assembly instructions

Lovibond RT300 User manual

Lovibond

Lovibond RT300 User manual

Lovibond SensoDirect pH200 User manual

Lovibond

Lovibond SensoDirect pH200 User manual

Lovibond Scuba+ User manual

Lovibond

Lovibond Scuba+ User manual

Lovibond CheckitDirect User manual

Lovibond

Lovibond CheckitDirect User manual

Lovibond SD 300 pH User manual

Lovibond

Lovibond SD 300 pH User manual

Lovibond SWIMTEC MD100 User manual

Lovibond

Lovibond SWIMTEC MD100 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SD 90
Salt
Lock/Unlock Data!
C. Backlight ON/OFF
____________________________________________________________________________________________
Note: Icons/Characters in RED meaning "BLINK"
: Hit once / : Press and hold / : Release
3
F. Store Data
1. In lock mode: 2s
2. In measurement mode: 2s (or 2s )
3. When the storage is full, it will overwrite the oldest data.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
G. System Setup
Menu selection:
2s (latest memory#)
(7.00 or 6.86) (dd-mm-yy/24hr or mm-dd-yy/12hr) (°C or °F)
(31-12 24 or 12-31 12ampm) .....
To enter:
!
MEASUREMENT
Salt CALIBRATION
Characters in RED represent „Flashing symbols“.
Remove protective cap from the probe
D. Store Data
Press
Press for
3 seconds
Press and
hold
+
+
+
1 2 3
4 5 6
+
-
--
-
Insert the batteries
unlock
off
off
unlock
off
Automatically turns off after 8 minutes of
inactivity.
Possible slight delay after pressing
before freeze of the data (!).
After 3 sec. the file no. temporarily appears
on the display, e.g. 01.
Once the storage has reached max. capacity,
the data will overwrite the oldest files.
off
lock
on
on
• Re-Calibrate according to individual recommendations! Rinse the electrode
with destilled water after each measurement.
• If temperature is out of range, „ERR“ will appear. Meter automatically returns to Measurement Mode.
• If the default reading is more than 30% out of standard buffer range, „ERR“ will appear.
Remove protective cap from the probe.
Power ON (see A)
GB
Immerse the probe
into calibration
solution.
wait
wait
Immerse the probe into
calibration solution.
E. Calibrate Salt
Auto-recognition for : 100~1000 ppm and : 1.00~20.00 ppt
to increase (+):
to store
to store
to decrease (-):
To decrease (-)
Adjustment:
Adjustment:
+
+
∞
∞
∞
to increase (+):
!
V. Set Data/Time display type
VI. Electrode Replacement
SETUP
I. Recall Data
II. Select Unit (% or ppt/ppm)
III. Set Date and Time
IV. Set Temperature system (°C/°F)
3 sec
3 sec
3 sec
3 sec
3 sec
3 sec
3 sec
3 sec
Minutes
Minutes
24 h
AM
PM
Hours
Hours
Year
Year
Month
Day
Day
Month
F. System Setup
Unfreeze data rst (see frontside B) before Menu selection.
Delete stored data.
Automatic Exit
Select V. `Set Data/ Time display type‘ first.
to increase (+);
am/pm 12 hour clock
24 hour clock
new electrode
to decrease (-)
am/pm
12 hour clock
or 24 hour
clock
Adjustment:
2x
1x
3x
4x
Press for
further files. Exit
Exit
Exit
Exit
Exit
°C °C
select select
°F
123
4 5 6
Content
1 Salt Meter SD 90 in a robust
plastic case with strap
2 Batteries
1 Instruction Manual
Code: 19 48 04
Instruction manuals available in further languages, visit www.lovibond.com
Accessories
195 00 17 Battery CR 2032 (2 Batteries required)
19 48 22 Replacement electrode
38 48 01 Beaker, 100 ml
Exit
Characters in RED represent „Flashing symbols“.
Recall Data
go to l.
Set Temperature
go to lV.
Select Unit
go to ll.
Set Data/Time display
type go to V.
Set Date and Time
go to lll.
To enter.
1x
4x
3x
2x
3 sec
Error Code and Actions
Description Range Actions
1Electrodenotinstalledorbad Thermistor:0.5~100kΩ Installorreplaceelectrode
2 Not used
3 Temperature out of range 0~60°C Bring solution to the temperature within range
4 Not used
5 Calibrated value out of range 70 %-130 % (compare Re-calibrate or replace the electrode or use
to the default value) the default value (remove batteries)
6 Salt out of range <20.00ppt (2.00%) Use other solution
Error Code and Actions
Description Range Actions
1Electrodenotinstalledorbad Thermistor:0.5~100kΩ Installorreplaceelectrode
2 Not used
3 Temperature out of range 0~60°C Bring solution to the temperature within range
4 Not used
5 Calibrated value out of range 70 %-130 % (compare Re-calibrate or replace the electrode or use
to the default value) the default value (remove batteries)
6 Salt out of range <20.00ppt (2.00%) Use other solution
SD 90 Salt Specications/Features
1 Operating range: 0~60°C, <20.00ppt(2.00%)
2 Automatic switch over ppm and ppt. ppm:0~999ppm; ppt:1.00~20.00ppt (when set to ppt/ppm unit)
3 Up to 2 points manual mode calibration, +/-50% adjustable value
4 Salt resolution: 0.01% (when set to „P“% unit); Accuracy: ±3%FS
5 Salt resolution: 1ppm(<=999ppm) and 0.01ppt(1.00~20.00ppt) (when set to ppt/ppm unit); Accuracy: ±3%FS
6 Temperature resolution: 0.1°C; Accuracy: ±1°C , Selectable °C/°F system
7 Selectable unit system („P“% or ppt/ppm)
8 Time and date display/stamp with 25 sets of data storage (non-volatile)
9 22x22mm LCD screen, with Yellow Green backlight
10 2x CR2032 batteries
11 Auto-power off to save battery (8 minutes non-use)