Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2022 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 2216
Model SEQ-4A Rev. 09-20-22 | pg. 1/3
INTERNAL USE ONLY: PN 24188
Compact low voltage four step sequencer model SEQ-4A is
designed to work with a single external switch or voltage input
and low voltage remote power controls (RPCs) to provide time-
delayed activation and deactivation of AC powered equipment
on site or at remote locations.
Note: This sequencer is for use with compatible components that feature classic
connections. It is not for use with devices that feature pass-through connections.
FEATURES:
• Power Requirement: 100-240VAC 12W
• Activation Trigger: This sequencer requires an external
source for activation. See last page for compatible
components.
– Single remote SPST switch with maintained contact closure.
– Mulltiple remote SPST switches with momentary contact
closure and Lowell's MSM2 module connected between
the sequencer and switch.
– Voltage input (5V-24V, AC or DC)
• Four (4) Step Delay:
– Time-delayed closure circuits activate in sequential order
(1, 2, 3, 4) and deactivate in reverse order.
– The delay between steps can be adjusted by setting the DIP
switch on the front (2.5 to 12 seconds between steps). A
reference chart is printed on the top of the chassis.
– LEDs provide visual status of the activation sequence.
– Includes auxiliary 24VDC output (300mA max.) for use with
remote indicators, if needed.
• Compact Chassis: 8.00" x 3.25" x 1.95" (4 lbs.) steel
chassis with black powder epoxy finish and mounting holes.
– Unit can be installed in a remote location or rack panel (2U).
– Operational diagram printed on chassis aids system set-up.
• Country of Origin: Made in U.S.A. with global components
• Power Supply: UL Listed power supply (100-240VAC input,
24VDC 500mA output) with 6 ft. cord and NEMA 1-15P plug.
Includes three adaptors for international use (Schuko CEE
7/16, BS1362, AS3112).
• Installation: The sequencer is typically installed in a
convenient location, while remote power controls are placed
near equipment to be controlled in another rack, room or
building.
– Maximum distance between switch, sequencer and remote
power controls: 22 gauge wire = 6,600 ft.; 18 gauge wire
= 17,160 ft.
– System Capacity: Accepts up to 10 RPCs per step.
• Connections: Order compatible remote power controls and
switches separately.
• A&E Specications: The four step sequencer shall be Lowell
model SEQ-4A, which shall feature barrier strip terminals for
connection to a single external remote switch with maintained
contact closure, multiple remote switches with momentary
closure and Lowell MSM2 module wired between them, or a
voltage input trigger. The sequencer shall connect to external
remote power controls (RPCs) to activate remote equipment in
four steps with an adjustable time delay between each step.
It shall activate RPCs in order (1, 2, 3, 4) and deactivate them
in reverse order. The sequencer shall feature a steel chassis
with mounting holes, black powder epoxy finish, and overall
dimensions of 8.00" x 3.25" x 1.95". It shall be made in the
USA with global components, and include a UL Listed power
supply with NEMA 1-15 plug and three adaptors (Schuko
CEE 7/16, BS1362, AS3112). External switches and remote
power controls shall be ordered separately.
Low Voltage Sequencer (4 step): SEQ-4A
INPUT for activation trigger
Chart for connections
LEDs show sequencing status
OUTPUT to connections
(up to 10 RPCs for each circuit)
Includes power supply
with NEMA 1-15 plug
and three adaptors
Made in U.S.A
with global
components
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2022 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 2216
Model SEQ-4A Rev. 09-20-22 | pg. 2/3
INTERNAL USE ONLY: PN 24188
INPUT CONNECTION OPTIONS:
OUTPUT CONNECTION OPTIONS:
V+
Sw
ON Ind.
OFF Ind.
V+
Sw
ON Ind.
OFF Ind.
Connect to
MOMENTARY
RemoteSwitches
+24V
Com
N.O.
N.C.
Model MSM2
Connect
to RPC
See Spec/Install sheet
for application de ta il s
Off
On
Connect to any physical switch or
control system that will provide a
maintained dry contact closure
Dry Contact Control
Switch
Common
24VDC Output
200mA max
Trigger Inpu t
5v – 24v AC or DC
Co
nnect to any device or control system
that will provide a maintained voltage
between 5 and 24 volts AC or DC.
If DC, observe polarity:
Common=Neg, Trigger Input=Pos.
Voltage Control
Switch
Common
24VDC Output
200mA max
Trigger Input
5v – 24v AC or DC
Any Lowell RPSW or RPSB series maintained contact
remote switch model (rocker or keylock)
On On
Rocker
Swit ch
Key
Swit ch
Swit ch
(Sw)
Com
+24V
2.2K 1/2W
Resistor
Schematic
Grn LED
Single Remote Switch Control
Switch
Common
24VDC Output
200mA max
Trigger Inpu t
5v – 24v AC or DC
Switch
Common
24VDC Output
200mA max
Trigger Inpu t
5v – 24v AC or DC
Key
Swit ch
OnOff
(Con ne ct
to NO)
Grn LED
2.2K 1/2W
Resistor
V+
Swit ch
(Sw)
ON Ind.
Red LED
OFFInd.
Schematic
Any Lowell RPSW2-M or RPSB2-M series momentary
contact remote switch model (rocker or keylock)
Max. 6 switches
Multiple Remote Switch Control
Connect to
either terminal
MSM2 Momentary Switch Module
SEQ-4A
SEQ-4A
SEQ-4A
SEQ-4A
Wire requirements:
Any generic cable, shielding not neede
d
Maximum distance between devices:
22ga wire: 1 mile
18ga wire: 3 miles
2 cond.
2 cond.
3 cond.
3 cond.
4 cond.
Rocker
Swit ch
OnOff
Norm
Test
Activated
Power
Inpu t 5v-24v
AC or DC
+24VDC Ou t
Common
Switch
G
G
Surg e Protection Active
When Lit (-S mo de ls only)
L
L
o
o
w
w
e
e
l
l
l
l
RPC Series
Remote Powe r Co ntrol Un it
R
G
R
No rm
Test
Pwr
Activat ed
Swit ch
Comm on
24VDC Output
20 0mA max
Trigger In put
5v – 24 v AC or DC
No rmally Closed
No rmally Closed
No rmally Open
No rmally Open
Co mmon
Co mmon
RPC unit
(any model)
RY-2A or RY-4A Relay Module
To additional RPCs
and/or relay modules
Step 1 connections shown
Steps 2, 3, and 4 connections are identical.
NOTE:
Any combination of RPC series models
and/or RY series models may be
connected to each sequencer step
Maximum 75 units per sequence step.
Wire requirements:
Any generic cable, shielding not needed
Maximum distance between sequencer and RPCs / relays:
22ga wire: 1 mile
18ga wire: 3 miles
NOTE: Maintain polarity
(switch to switch, com to co
m)
2 cond.
Delay Settings
ON
Approx. 5 sec.
between steps
20 seconds total
ON
Approx. 2½ sec.
between steps
10 seconds total
ON
Approx. 8 sec.
between steps
32 seconds total
Approx. 12 sec.
between steps
48 seconds total
ON
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2022 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 2216
Model SEQ-4A Rev. 09-20-22 | pg. 3/3
INTERNAL USE ONLY: PN 24188
OPTIONS: (order separately)
• SWITCH for single switch applications: (RPS Series switch with maintained closure)
Model Description Model Description
RPSW-P 1 LED rocker switch, white wall plate RPSW-KP 1 LED key switch, white wall plate
RPSB-P 1 LED rocker switch, black wall plate RPSB-R 1 LED rocker switch, 19" panel
RPSB-KR 1 LED key switch, 19" panel RPSB-R-RJ 1 LED rocker switch, 19" panel, RJ45
RPSB-KR-RJ 1 LED key switch, 19" panel, RJ45 RPSW-P-RJ 1 LED rocker switch, white wall plate, RJ45
RPSW-KP-RJ 1 LED key switch, white wall plate, RJ45 RPSB-P-RJ 1 LED rocker switch, black wall plate, RJ45
• SWITCH for multiple-switch applications: (RPS Series switch with momentary closure and MSM2 module, see chart below)
Model Description Model Description
RPSW-MP 1 LED rocker switch, white wall plate RPSW2-MP 2 LED rocker switch, white wall plate
RPSB-MP 1 LED rocker switch, black wall plate RPSB2-MP 2 LED rocker switch, black wall plate
RPSB-MR 1 LED rocker switch, 19" panel RPSB2-MR 2 LED rocker switch, 19" panel
RPSW-MKP 1 LED key switch, white wall plate RPSW2-MKP 2 LED key switch, white wall plate
RPSB-MKP 1 LED key switch, black wall plate RPSB2-MKP 2 LED key switch, black wall plate
RPSB-MKR 1 LED key switch, 19" panel RPSB2-MKR 2 LED key switch, 19" panel
RPSB2-MP-RJ 2 LED rocker switch, black wall plate, RJ45 RPSW2-MP-RJ 2 LED rocker switch, white wall plate, RJ45
RPSB2-MKP-RJ 2 LED key switch, black wall plate, RJ45 RPSW2-MKP-RJ 2 LED key switch, white wall plate, RJ45
RPSB2-MR-RJ 2 LED rocker switch, 19" panel, RJ45 RPSB2-MKR-RJ 2 LED key switch, 19" panel, RJ45
• REMOTE POWER CONTROL: (RPC Series with classic connections)
Model Description Model Description
RPC-15 RPC with (2) 15A NEMA outlets, cord RPC-15-S RPC with (2) 15A NEMA outlets, surge supp, cord
RPC-15-SCD-RJ RPC with (2) 15A NEMA outlets, cord, RJ45 RPC-15-U RPC with (2) IEC C13 oulets, cord
RPC-20-CD RPC with (2) 20A NEMA outlets, cord RPC-20-SCD RPC with (2) 20A NEMA outlets, surge supp, cord
RPC-20-SCD-RJ RPC with (2) 20A NEMA outlets, surge supp, cord, RJ45 RPC-3N1 RPC with (8) 15A NEMA outlets, cord
RPC-20-HW RPC with (2) 20A NEMA outlets, whip RPC-20-SHW RPC with (2) 20A NEMA outlets, surge supp, whip
RPC-30-SHW RPC with 30A Twistlock outlets, surge supp, whip
This
spec
SEQ & SEQR Series Overview — sequencers with classic connections
Alternate
REQUIRES ACCEPTS ACCEPTS ACCEPTS
Sequence Onboard External Multiple Remote Input from Input from Lowell Power Country
Model No. Chassis Steps Mode Switch Switch Switches Alarm System Switch w/RJ45 Input of Origin
SEQ-4A standalone 4 --- --- yes through
MSM2
--- --- power supply USA
SEQ-8 standalone 8 --- --- yes yes --- --- power supply USA
SEQR-4 1U panel 4 --- rocker --- yes yes --- power supply USA
SEQR-4K 1U panel 4 --- key --- yes yes --- power supply USA
SEQR-8 1U panel 8 yes rocker --- yes yes --- power supply USA
SEQR-8K 1U panel 8 yes key --- yes yes --- power supply USA
SEQR-8RJ 1U panel 8 yes rocker --- yes yes yes power supply USA
Steps = Unit activates/deactivates connected remote power controls (RPCs) in four or eight steps, with a delay between each. Up to 10 RPCs can connect to each step.
Alternate Sequence Mode = The ASM feature skips selected outputs to allow partial startup of system, useful for small events or rehearsals. It requires remote switch
model RPSB-KP-ASM to enable ASM function before main switch is activated.
Onboard Switch = Sequencers without an onboard switch will require an external switch for activation.
REQUIRES External Switch = Sequencer can be controlled by one external switch, usually placed in a remote location (RPS series switch with MAINTAINED closure).
ACCEPTS Multiple Remote Switches = Sequencer can be controlled by one or more external switches placed in remote locations (RPS Series switches with
MOMENTARY closure). Some models require the MSM2 module in order to accept multiple switches.
ACCEPTS Input from Alarm System = Sequencer can accept control override from an alarm system (alarm by others, not included).
ACCEPTS Input from Lowell Switch w/RJ45 = Sequencer is designed for use with a Lowell MOMENTARY switch that has a model number with "-RJ" as a suffix (see
options above). Note that these switches include a single RJ45 connector and are not part of Lowell's "pass-through" series.
NOTE: For rackmount sequencers that include AC power outlets, see Lowell ACR Series or ACSPR Series.

Other Lowell Recording Equipment manuals

Lowell SEQ-8 User manual

Lowell

Lowell SEQ-8 User manual

Lowell EQ1 Assembly instructions

Lowell

Lowell EQ1 Assembly instructions

Lowell SEQR-4 User manual

Lowell

Lowell SEQR-4 User manual

Lowell SEQR-8RJ User manual

Lowell

Lowell SEQR-8RJ User manual

Lowell SEQ-4 User manual

Lowell

Lowell SEQ-4 User manual

Popular Recording Equipment manuals by other brands

Acrosser Technology AR-B3001 manual

Acrosser Technology

Acrosser Technology AR-B3001 manual

PRESONUS Studio 1824c Getting started

PRESONUS

PRESONUS Studio 1824c Getting started

Simplex 2100 installation instructions

Simplex

Simplex 2100 installation instructions

M-Audio code25 user guide

M-Audio

M-Audio code25 user guide

IBT SDI-DZK installation guide

IBT

IBT SDI-DZK installation guide

Alesis ADAT-LX20 Reference manual

Alesis

Alesis ADAT-LX20 Reference manual

Roland CD-2i quick start

Roland

Roland CD-2i quick start

Sony XDCAM PDW-HR1 brochure

Sony

Sony XDCAM PDW-HR1 brochure

Sony Walkman PCM-M1 operating instructions

Sony

Sony Walkman PCM-M1 operating instructions

Eaton NZM-XDMI612 Instruction leaflet

Eaton

Eaton NZM-XDMI612 Instruction leaflet

TC Electronic M-ONE quick guide

TC Electronic

TC Electronic M-ONE quick guide

Waldorf 2-pole user guide

Waldorf

Waldorf 2-pole user guide

Vocal Booth To Go FlexTee Assembly instructions

Vocal Booth To Go

Vocal Booth To Go FlexTee Assembly instructions

Worlde KSA SERIES user manual

Worlde

Worlde KSA SERIES user manual

BLACK NOISE DRII Build instructions

BLACK NOISE

BLACK NOISE DRII Build instructions

Furman PS8 R II owner's manual

Furman

Furman PS8 R II owner's manual

Extron electronics RGB 190FM user manual

Extron electronics

Extron electronics RGB 190FM user manual

Soniclear Evo 4 Operation guide

Soniclear

Soniclear Evo 4 Operation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.