manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ltech
  6. •
  7. Control Unit
  8. •
  9. Ltech Artnet-DMX-2 User manual

Ltech Artnet-DMX-2 User manual

Artnet-DMX-2
Artnet-DMX Converter
1
Artnet-DMX-2
1. Technical specs
3. Product dimension
2
2. Performance features
warranty
5 years
73
120
45
Artnet-DMX converter is the Ethernet Control System based on the Artnet protocol, used to convert the Artnet
network data package into DMX512 data, adopting high-speed ARM processor, stable and reliable working.
Following Artnet standard protocol, it supports RJ45 network interface and standard DMX512 output interface.
It is compatible with all the effects lighting control software which support Artnet protocol, widely used in the
LED dot matrix and the stage lighting control network in needing lots of DMX512 data, especially for TV station
recorded scene, stage performances, entertainment and so on.
2.1 Based on Artnet protocol network data communication, accept network DMX data;
2.2 IP address is bound to Subnet, no need to reset, plug and play.
2.3 Manage Artnet on broadcast mode or unicast mode.
2.4 Output 2 group DMX512 data.
2.5 Firmware can be updated via the network.
2.6 Compatible with the light software based on Artnet Protocol, control stage lighting and LED lighting
simultaneously.
2.7 Connect up to 256 DMX Universes to one network.
2.8 10BaseT Ethernet Port.
2.9 Data activity indicators
2.10 Configurable DMX output refresh rates.
Artnet-DMX-2 Artnet-DMX Converter Artnet-DMX-2 Artnet-DMX Converter
Artnet-DMX-2 has two standard DMX512 data output port, output 1024 data in total.
12Vdc (with a power adaptor) RJ45
Network Connection:
3-pin XLR
Output signal: DMX512
IP: Indoor use only
Power input:
Input signal: Artnet
Current: 30mA@12Vdc
DMX channels: 512 × 2CH
DMX Output Connection:
L120×W73×H45mm
L198×W78×H50mm
360g
-30 ~65℃ ℃
Working temperature:
Dimension:
Package Size:
Weight (G.W):
Isolation Ethernet Port: Transformer isolation
www.ltech-led.com
Artnet-DMX-2 Artnet-DMX Converter Artnet-DMX-2 Artnet-DMX Converter
Address setting instruction:
Universe/Sub-Net Dip Switch
1 2 345678 9 A B C D E F
0
Value 1 2 345678 9 10 11 12 13 14 150
Calculating method: Group address= Subnet×16 + Universe, IP Address=2.xx.xx.Group Address,
MAC Address=44-4d-58-2d-31-Group Address (xx is the random number generated by the factory)
For example: Subnet: 2, Universe: B, Group Address=2×16 + 11 = 43, so the DMX output
group address is 43, Corresponding IP address is 2.xx.xx.43, MAC address is 44-4d-58-2d-31-43.
DMX Output1
DMX Output2
Status lamp
Status lamp
1
2
3
DMX OUT1
1
3
2
PUSH
PU SH
1
3
2
GND
DATA-
DATA+
DMX OUT2
1
2
3
1
2
3
3 4 www.ltech-led.com
1
2
ON
Sub-Net
Universe
Fun
Ethernet
DC12V
Artnet input
Power Input
Universe Dip Switch
Mode Switcher
(Operation as follows)
Subnet Dip Switch
Status lamp
4. Interface instruction
12
OFF
ON
OFF
OFF
ON OFF
1 2
ON
1 2
ON
1 2
ON
Diagrams
Switching modes operation instruction :
Functions
4
5
3
6
2
7
1
8
0
9
A
F
B
E
C
D
4
5
3
6
2
7
1
8
0
9
A
F
B
E
C
D
Universe
Sub-Net
1 2
Fun
ON
IP Address Setting: 2.0.36.Address
IP Address Setting: 10.0.36.Address
Testing function, OUT1 generates 170 pixels full color jumping DMX data,
OUT2 generates 170 pixels full color smooth float DMX data.
www.ltech-led.com
Artnet-DMX-2 Artnet-DMX Converter Artnet-DMX-2 Artnet-DMX Converter
5. Conjunction diagram
Artnet-DMX-2 Lighting Control System Diagram
Artnet-DMX-2
Router
Computer
XLR-3
cable
XLR-3
cable
XLR-3
cable
RJ45
cable
RJ45
cable
RJ45
cable
RJ45
cable
Artnet-DMX-2
Artnet-DMX-2
Moving head light
Moving head light
Moving head light
Par light
Par light
Par light
1
3
2
PUSH
PUSH
1
3
2
1
3
2
PUSH
PUSH
1
3
2
1
3
2
PUSH
PUSH
1
3
2
6. Connect ArtNet-DMX-1 to the computer
6.2 Use the equipped adapter to power ArtNet-DMX-2.
6.3 Connect ArtNet-DMX-2 and computer via the cable.
6.1 Install the Madrix 3 software in the computer, the icon on the desktop :
MADRIX 3
6.4 IP setting: this control system is compatible with random network segment. According to the ArtNet
protocol, 2.X.X.X or 10.X.X.X can be added in the computer ( X means arbitrary value), methods as below:
This product is compatible with all the ArtNet software in the market, here take MADRIX as an example:
6.4.1 Open the Network, click
“Properties” button of the
TCP/IPv4 protocol.
6.4.4 Add the IP address 2.X.X.X or
10.X.X.X (X could be arbitrary value).
6.4.5 Interface of adding successful,
click “OK” and exit.
6.4.2 Click “ Advanced”. 6.4.3 Click “ Add”.
Artnet-DMX-2 Artnet-DMX Converter Artnet-DMX-2 Artnet-DMX Converter
7 8
8. Warranty agreement
8.1 We provide lifelong technical assistance with this product:
8.4 Any amendment or adjustment to this warranty must be approved in writing by our company
only.
8.3 Repair or replacement as provided under this warranty is the exclusive remedy to the
customer. We shall not be liable for any incidental or consequential damages for breach
of any stipulation in this warranty.
8.2 Warranty exclusions below:
For faults beyond the 5-year warranty, we reserve the right to charge for time and parts.
A 5-year warranty is given from the date of purchase. The warranty is for free repair or
replacement if cover manufacturing faults only.
Any man-made damages caused from improper operation, or connecting to excess voltage
and overloading.
7. Attention
7.1 The product shall be installed and serviced by the qualified person.
7.7 If a fault occurs please return the product to your supplier. Do not attempt to fix this product
by yourself.
7.6 Ensure all wire connections and polarities are correct before applying power to avoid any
damages to the LED lights.
7.5 Please ensure that adequate sized cable is used from the controller to the LED lights to carry
the current. Please also ensure that the cable is secured tightly in the connector.
7.4 Please check if the output voltage of the LED power supply used comply with the working
voltage of the product.
7.3 Good heat dissipation will prolong the working life of the controller. Please ensure good
ventilation.
7.2 This product is non-waterproof. Please avoid the sun and rain. When installed outdoors, please
ensure it is mounted in a water proof enclosure.
The product appears to have excessive physical damage.
Damage due to natural disasters and force majeure.
Warranty label, fragile label and unique barcode label have been damaged.
The product has been replaced by a brand new product.
6.5 Open Madrix 3 software, choose“preferences”>" device manager" from menu.
6.6 In "device manager" dialog, choose "ArtNet" tab, tick “enable” and click search . Artnet-DMX-2 will be
searched.
6.7 Click the tab of "DMX devices", set port status to “ON” if connected successfully. Now, you can use computer to
control lamps via ArtNet-DMX-2.
MADRIX is registered trademarks of Inoage GMbH Co., Inc. in Germany.
No further notice if any changes in the manual.
Product function depends on the goods.
Please feel free to contact your supplier if any question.
Update Time: 2019.11.12
*
www.ltech-led.com

Popular Control Unit manuals by other brands

Atest Gaz EcoAlpa PW-054 Series user manual

Atest Gaz

Atest Gaz EcoAlpa PW-054 Series user manual

Pfeiffer Vacuum OmniControl operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum OmniControl operating instructions

SSS Siedle ZVM 711-02 Product information

SSS Siedle

SSS Siedle ZVM 711-02 Product information

Teledyne 2108 Installation and operation guide

Teledyne

Teledyne 2108 Installation and operation guide

Samson 3222 Series Mounting and operating instructions

Samson

Samson 3222 Series Mounting and operating instructions

NI 9866 operating instructions

NI

NI 9866 operating instructions

RS PRO 209-6384 Instruction leaflet

RS PRO

RS PRO 209-6384 Instruction leaflet

ITS Telecom Master Unit EKOAX IPC-M user manual

ITS Telecom

ITS Telecom Master Unit EKOAX IPC-M user manual

Allen-Bradley 1791-16BC manual

Allen-Bradley

Allen-Bradley 1791-16BC manual

Flyron Technology Co., Ltd. FN-168R user manual

Flyron Technology Co., Ltd.

Flyron Technology Co., Ltd. FN-168R user manual

Instron 2701 Series Reference manual

Instron

Instron 2701 Series Reference manual

CALEFFI 677 Series manual

CALEFFI

CALEFFI 677 Series manual

Vimar Eikon 20541 manual

Vimar

Vimar Eikon 20541 manual

Wiznet WIZ610wi user manual

Wiznet

Wiznet WIZ610wi user manual

Schaudt LT 500 instruction manual

Schaudt

Schaudt LT 500 instruction manual

Rockwell Automation Allen-Bradley 1794-IRT8 user manual

Rockwell Automation

Rockwell Automation Allen-Bradley 1794-IRT8 user manual

Bosch PAVIRO PVA-1WEOL user manual

Bosch

Bosch PAVIRO PVA-1WEOL user manual

Emerson KEYSTONE OPTISEAL F16 Installation and maintenance instructions

Emerson

Emerson KEYSTONE OPTISEAL F16 Installation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.