LTSscale.com Page 5 of 28 REV F –2018.04.09
KEYBOARD CONTROLS
This section examines the functions of the various keyboard operations that can be performed on
the DR2100 indicator. There are 21 keys on the keyboard; 10 numeric key (0-9), 10 function keys
plus RESET Key.
Label Keyboard Function
Optional key
Press to zero scale (with no load on the scale and forks off of the floor).
Press to display Net or Gross weight (only displays net when a tare is entered).
Enter the weight of the empty container. Press STORE TARE key.
-Or-pick up empty container press STORE TARE key.
To clear tare: press 0key. Press STORE TARE key.
Press to toggle between weigh and count modes.
Used to enter the Average Part Weight for piece counting purposes.
Press APW key. Key in the average part weight. Press ENTER Key.
See WEIGH/COUNT key.
To enter an ID number, key in an ID number. Press ID key.
Recall the ID number, press and hold ID key.
To clear the ID number, press 0. Press ID key.
Lift load, press ACCUM key. Weight and count are stored. Remove load.
Lift second load, press ACCUM key. Weights and counts will be added to previous
values. Press and hold ACCUM key to display accumulated weight.
To clear, press 0. Press ACCUM key.
Press PRINT key to send data out the data port.
Press DEL key to backspace one digit when entering a numeric value, also used to
toggle between selections.
Clears erroneous numbers that were keyed in. For lb/kg switching press once and then
press DEL key. Press twice to recall a stored tare weight.
Used to reset the indicator.
To reset, hold down DEL and the Rkeys, push and release Rkey, wait 2 seconds to
reset