Lumin Smart Panel User manual

Lumin Smart Panel
WWW.LUMINSMART.COM
INSTALLATION
MANUAL
V3.1

® U.S. Registered Trademark. Patents pending.
Copyright © 2019 Coulomb, Inc. (DBA Lumin). All rights reserved.

Lumin Smart Panel
INSTALLATION MANUAL
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Read Before Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Pre-Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Items In the Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Tools You Will Need . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Configuration & Account Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Limited Warranty for Lumin Smart Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

WARNING: HIGH VOLTAGE.
THE LUMIN SMART PANEL MUST BE INSTALLED BY A LICENSED
ELECTRICIAN
INTRODUCTION
Welcome! The Lumin Smart Panel (LSP) is a stand-alone product that extends the capability
of an existing circuit breaker panel (or “electrical panel”) by providing measurement and
remote control of up to twelve (12) circuits in a home or building. The function of the circuit
breaker panel remains the same and is not impacted. The LSP securely and safely transmits
real-time consumption information to the cloud via Ethernet connection or customer Wi-Fi.
The information can be accessed through a user dashboard (software) for home/building
owners. The Lumin dashboard gives customers insights into their energy consumption and
energy costs, as well as provides the user with the ability to control or automate their
energy use remotely.
"
This manual describes the installation of the LSP hardware. All information regarding access
to the user dashboard can be found in the Account Set Up Guide or by going to
https://luminsmart.com/accountsetup.
"
Need help? For installation assistance please contact Lumin by e-mail at
1

READ BEFORE USE
The LSP is compatible with both flush-mounted (i.e. set within drywall) existing electrical
panels and surface-mounted electrical panels. Please determine which electrical panel type
the LSP will be connecting to and follow the corresponding installation steps outlined in this
manual. The LSP must be installed indoors. Please review the product’s technical ratings
and specifications (pg. 26) to confirm it is suitable for your application prior to installation.
NOTE: The LSP Circuit Label & CT Table (provided with the LSP) must be completed and
delivered to the home/building owner upon the successful installation of the LSP. A
completed LSP Circuit Label & CT Table is required in order for users to set up their Lumin
account.
Warnings
The LSP connects to dangerous voltages. The improper use or installation of the device can
lead to serious or fatal injuries. Please observe the following safety precautions when
installing the LSP:
"
• The product must be installed by a licensed electrician
• Review all the instructions before you start the installation
• Personal protective equipment should be worn when installing the product
• Do not use the product in any way other than its intended use
• Do not install or operate the product outdoors or in damp/wet conditions
• Do not install or operate the product in extreme temperatures
• Do not open, attempt to access or touch any internal product parts
• Do not use the product if it is damaged or appears to be damaged
• Use only the wires and cables supplied with the product
• Do not connect the product to circuit breakers rated higher than 60 amps
• Do not connect the product to any loads that exceed 1.5 horsepower
• Adhere to all local and national safety regulations for installation and use
2
Lumin Smart Panel
INSTALLATION MANUAL

PRE-INSTALLATION CHECKLIST
Items in the Box
1 LSP with Conduit, Conduit
Bushings & Wire Whips Attached
2 Mounting Brackets
(Surface-mounted Installation)
NOTE: Additional items include an antenna, installation hardware, a LSP Circuit Label & CT
Table, an Account Setup Guide and an Installation Overview.
3
1 Pair of 200A Current Transformers
(A second pair is optional)

Drill Manual knockout
Phillips screwdriver
Tape measureDrywall Saw (optional)
Flathead screwdriver Level (optional)
Wire nuts
Wire stripper
PRE-INSTALLATION CHECKLIST
Tools You’ll Need
4
Lumin Smart Panel
INSTALLATION MANUAL

INSTALLATION
Installation Overview
STEP 11. Connect a LSP wire labeled
“Line # A” to the circuit breaker
STEP 12. Connect a LSP wire labeled
“Line # B” to the load & turn circuit
on
STEP 13. Record circuit breaker
name and phase (A or B) with
corresponding LSP wire number
STEP 14. Repeat steps 10-13 until all
LSP Line # wires are connected
STEP 15. Connect & attach the 200A
CTs to the main service lines
STEP 16 (Optional). Connect &
attach the second pair of CTs to PV/
Solar generation output
STEP 17. Record the line name of the
corresponding attached CTs
STEP 18. Connect the LSP’s grid
voltage wires to an ATS or main
distribution panel
STEP 19. Replace the electrical panel
cover
STEP 1. Turn offmain feed & remove
the electrical panel cover
STEP 2 (Flush-mount Only). Cutout
& remove drywall for LSP access
STEP 3. Knock out a 2” hole in the
electrical panel
STEP 4. Measure & mark hole
locations for mounting the LSP
STEP 5 (Surface-mount Only).
Secure mounting brackets to the wall
STEP 6. Attach the LSP”s antenna and
guide the LSP’s wire whip through the
electrical panel
STEP 7. Secure the LSP to the wall/
bracket & electrical panel
STEP 8. Connect the LSP ground wire
to the ground bar
STEP 9. Connect the LSP power cable
harness
STEP 10. Select a circuit breaker, turn
it off& disconnect the load
5

Tools: Screwdriver
Installation Steps
STEP 1.
6
WARNING:
HIGH VOLTAGE.
Lumin Smart Panel
INSTALLATION MANUAL
Turn OffMain Feed and Remove Electrical Panel Cover

STEP 2 (Flush-Mount Only). Cutout and Remove Drywall
Tools: Tape measure, level (optional) and drywall saw or suitable alternative
NOTE: Cut and remove enough drywall to accommodate the LSP’s wire whips. Consider
drywall cutout “Option B” if additional space is required to accommodate the LSP’s wire
whips and to properly access the electrical panel to complete Step 3.
Drywall Cutout Option A Drywall Cutout Option B
7

STEP 3.
Tools: Knockout punch or suitable alternative
NOTE: Exact hole location in electrical panel may very depending on spacing constraints;
place the hole location below, above or to either side of the electrical panel as needed to
avoid any existing obstructions.
WARNING:
HIGH VOLTAGE.
8
Lumin Smart Panel
INSTALLATION MANUAL
Knock Out One 2” Hole in Electrical Panel for 2” Conduit

STEP 4. Measure and Mark Hole Locations for Mounting the LSP
Tools: Tape measure and level (optional)
NOTE: Ensure to mark the applicable hole locations for your installation type (flush-mount
vs. surface-mount mounting brackets). Exact hole locations may vary depending on existing
conditions.
Surface-mounted installation Flush-mounted installation
9

STEP 5 (Surface-mount Only). Secure Mounting Brackets to Wall
Tools: Drill, screws (x4) and washers (x4)
10
Lumin Smart Panel
INSTALLATION MANUAL

STEP 6.
NOTE: Attach the LSP’s antenna (provided with your LSP) and then guide the wire whip
through the hole in the electrical panel. Remove the conduit bushing before guiding the
wire whip through the hole.
Surface-mounted installation Flush-mounted installation
11
WARNING:
HIGH VOLTAGE.
Attach the LSP’s Antenna and Guide the LSP’s Wire Whip
Through the Electrical Panel
Attach
Antenna
Attach
Antenna

STEP 7. Secure the LSP to the Wall/Bracket and Electrical Panel
Tools: Drill, screws (x4), washers (x4) and nuts (x4: surface-mount only)
NOTE: Lift the LSP to align with the mounting holes and secure it directly to the wall (flush-
mount installation) or mounting brackets (surface-mount installation) utilizing the hardware
provided. Secure the LSP to the electrical panel with the 2” conduit bushing provided.
Surface-mounted installation Flush-mounted installation
12
WARNING:
HIGH VOLTAGE.
Lumin Smart Panel
INSTALLATION MANUAL

STEP 8. Connect the LSP Ground Wire to the Ground Bar
Tools: Screwdriver
NOTE: Connect the bare copper ground wire from the LSP to the existing ground bar in the
electrical panel (exact location of ground bar may vary).
13
WARNING:
HIGH VOLTAGE.
Ground Wire

STEP 9. Connect the LSP Power Cable Harness
14
Lumin Smart Panel
INSTALLATION MANUAL
Neutral
(white)
Line A (black) to
Phase A Breaker
Line B (red) to
Phase B Breaker
Tools: Screwdriver and wire stripper
NOTE: Connect the LSP wire labeled “Neutral” to the existing neutral bar in the electrical
panel; connect LSP wires labeled “Line A” and “Line B” to phase A and phase B breakers,
respectively via double-tapping the breakers (DO NOT USE GFCI BREAKERS). If existing
breaker will not accommodate a double-tap then connect via a three-way wire nut or via a
new, unpopulated breaker.
WARNING:
HIGH VOLTAGE.

STEP 10.
Tools: Screwdriver
15
WARNING:
HIGH VOLTAGE.
Disconnect Load
Select A Circuit Breaker to Connect to the LSP, Turn it Offand
Disconnect Load
Turn OffCircuit

STEP 11. Connect a LSP Wire Labeled “Line # A” to the Circuit Breaker
Line # A
Tools: Screwdriver and wire stripper
NOTE: All LSP wires labeled “Line # A” must connect to a breaker. Lines 1-6 (6 AWG wire) can
connect to circuit breakers rated up to 60 amps and lines 7-12 (10 AWG wire) can connect to
circuit breakers rated up to 30 amps. DO NOT connect the LSP to loads that exceed 1.5
horsepower.
16
WARNING:
HIGH VOLTAGE.
Lumin Smart Panel
INSTALLATION MANUAL

STEP 12.
Line # B
Tools: Wire stripper and wire nut
NOTE: All LSP wires labeled “Line # B” must connect to a load wire via a wire nut (ensuring a
tight connection). The LSP wire line number should match the line number used in the
previous step (ex. Line 3 A connects to a breaker & Line 3 B connects to that breaker’s load).
17
WARNING:
HIGH VOLTAGE.
Connect a LSP Wire Labeled “Line # B” to the Load and Then
Turn the Circuit Breaker Back On
This manual suits for next models
1
Table of contents
Popular Control Panel manuals by other brands

Fisher & Paykel
Fisher & Paykel ActiveSmart E372B operating instructions

Busch-Jaeger
Busch-Jaeger Busch-Welcome 83200-FM Series manual

Telex
Telex LCP-16 installation guide

LEGRAND
LEGRAND 5 735 04 Technical data

Galaxy
Galaxy Gel Pad Programming guide

Komfovent
Komfovent C4.1 Installation and operation manual

Visual Productions
Visual Productions B -STATION1 manual

Siemens
Siemens SINAMICS G130 operating instructions

Elkron
Elkron MP500/16 User addendum

Jackson Systems
Jackson Systems Comfort System Z-300-HP Wiring diagram

SALUPO
SALUPO EVO 3 Instruction and installation manual

Siemens
Siemens SIMATIC TD 200 user manual