READ THESE INSTRUCTIONS
THOROUGHLY BEFORE
INSTALLATION KEEP THESE
INSTRUCTIONS FOR
FUTURE REFERENCE.
IMPORTANT:
This product must be installed
by a qualifi ed electrician or
competent person, and in
accordance with current building
and IET wiring regulations.
• Light Fitting
• Instruction Manual
• Brackets
Frankly Plus
Floodlights
100W, 150W, 200W, 240W, 300W & 400W
IP66
Warranty
5 YR
Hours
50,000
Technical Helpline: +44 (0)1507 328031
www.lumineux.co.uk
1: Wall installation 1: Ceiling installation 1: Ground installation
2 2 2
on
off
3 3 3
4 4 4
Frankly Plus
Floodlghts
IK08
TOOLS REQUIRED
BOX CONTENTS
• Drill /
Screwdriver
• 8mm Allen Key
• Cable
INSTALLATION INSTRUCTIONS
on
off
Thislightingxturehasbeenproperly
packedtoavoiddamageduring
transit.Beforecommencingwiththe
installationcarefullyinspectthe
luminairetoconrmthereisno
damage.DONOTINSTALLifany
damagehasoccurredtothexture
oranyofitscomponents.
Drilltwoholesin
the wall with an
electrichammer.
Useanelectrichammer
todrilltwoholesinthe
ceiling.
Drilltwoholesinthe
oorwithanelectric
hammer.
Useahammer
todrivethetwo
anchorboltsinto
thepreviously
drilledholes.
Useahammertodrivethetwoanchorboltsinto
thepreviouslydrilledholes.
Useahammertodrivethetwoanchorboltsinto
thepreviouslydrilledholes.
Loosengearadjustmentscrewsonleft&right
sides,thenalignthemountingholesofthebracket
withthetwoexpansionscrewsandtighten.
Loosengearadjustment
screwsonleft&right
sides, then align the
mountingholesof
thebracketwiththe
twoexpansionscrewsandtighten.
Loosengearadjustmentscrewsonleft&rightsides,
thenalignthemountingholesofthebracketwith
thetwoexpansionscrewsandtighten.
Tightenmountingbracketscrewsthenadjust
theilluminationangleofthelamp.Lockthegear
adjustmentscrewandconnectthepowerAC
inputlineonthelamptothemains.Complete!
Tightenmountingbracketscrewsthenadjust
theilluminationangleofthelamp.Lockthegear
adjustmentscrewandconnectthepowerAC
inputlineonthelamptothemains.Complete!
Tightenmountingbracketscrewsthenadjust
theilluminationangleofthelamp.Lockthegear
adjustmentscrewandconnectthepowerAC
inputlineonthelamptothemains.Complete!
AC Input
Gear adjustment
screw
AC Input
AC Input
270°
AC Input
AC Input
AC Input
Anchorbolts
Anchorbolts
Anchorbolts
• Turnoffthemainspowerbeforeperforming
 inspections,installation,orremoval
• Verifythatthesupplyvoltageiscorrectby
 comparingitwiththeluminairelabelinformation
• Itistheinstallersresponsibilitytoensureinstallation
 issuitableforthetotalloadoftheluminaire(s).The
 supplycable,fuses/circuitbrakersmustbecorrectly
 ratedfortheelectricalloadandconsideringforany
 transientinrushcurrentsthatmayoccur
• Donotperforminsulationstrengthorresistance
 testsoninstalledluminarie(s)connected
PLEASE READ THESE INSTRUCTIONS
BEFORE INSTALLATION.
WARNING: Risk of electric shock! Isolate
the mains power before proceeding.
Manby Business Park, Manby, Lincolnshire, LN11 8UT
Lumineux is a B&T Associates Ltd company.
EE
A
G
Frankly Plus Floodlights
Standard -20to+45ºC
Photocell -20to+45ºC
Technical Helpline: +44 (0)1507 328031
Revision 2 - March 2022
PRODUCT TEMP SPECIFICATION
Part No. Description Watts L(mm) W(mm) D(mm) Weight
430472-120 FranklyPlus
AsymmetricOptic 100W 402 377 62 4.15Kg
430473-120 FranklyPlus
AsymmetricOptic 150W 402 377 62 4.15Kg
430474-120 FranklyPlus
AsymmetricOptic 200W 464 377 63 4.90Kg
430475-120 FranklyPlus
AsymmetricOptic 240W 464 377 63 4.90Kg
430476-120 FranklyPlus
AsymmetricOptic 300W 630 377 77 7.20Kg
430475-120 FranklyPlus
AsymmetricOptic 400W 630 377 77 7.20Kg
FRANKLY PLUS FLOODLIGHT DIMENSIONS
W (mm) D (mm)
L (mm)
This luminaire is warranted for a
period of 5 years from the date of
purchase**.Thebackupbattery
packintheemergencyversion
iswarrantedforaperiodof12
months.Thewarrantycouldbe
invalidatedshouldthelighttting
notbeinstalledaccordingtothese
instructions,outsidethescopeof
thespecicationortheproduct
hasbeenalteredortamperedwith
inanyway.Pleaseseewebsitefor
termsandconditions.
DISPOSAL
WARRANTY
Disassemblyinstructionsforendof
lifedisposalavailableonwebsite.
DisposalofElectronicEquipment
WEEEDirective2002/96/ECThis
productfallswithinthescopeof
theWasteElectrical&Electronic
EquipmentDirective(WEEE),which
meanstheproductshouldnotbe
disposedofasnormalhousehold
waste.Pleaserecyclewhere
facilitiesexistorcheckwithyour
LocalAuthority.RoHS–All
componentsandmaterialsusedin
thisproductareRoHS2002/95/EC
compliant.
Specicationsmaychangefromtime
totime.Theinformationcontained
inthisleaetisforguidanceonly
andshouldnotbeconsideredas
alwaysaccurateandshouldbe
treatedasnotrepresentative.
** Please see our website for more detailed information on warranty.
ThisproductcontainsalightsourceofenergyefciencyClassE.

Other Lumineux Floodlight manuals

Lumineux Carsington Plus User manual

Lumineux

Lumineux Carsington Plus User manual

Lumineux LIFFORD User manual

Lumineux

Lumineux LIFFORD User manual

Lumineux Carsington Plus User manual

Lumineux

Lumineux Carsington Plus User manual

Lumineux Carsington Plus Sports User manual

Lumineux

Lumineux Carsington Plus Sports User manual

Lumineux Tring RGBW 10W User manual

Lumineux

Lumineux Tring RGBW 10W User manual

Lumineux Lifford User manual

Lumineux

Lumineux Lifford User manual

Popular Floodlight manuals by other brands

Wetelux 84 26 89 instruction manual

Wetelux

Wetelux 84 26 89 instruction manual

REV Ritter HFGT120AE Operation and maintenance manual

REV Ritter

REV Ritter HFGT120AE Operation and maintenance manual

Toplicht DHR 260DS manual

Toplicht

Toplicht DHR 260DS manual

Stahl TRANBERG TEF 2580 user manual

Stahl

Stahl TRANBERG TEF 2580 user manual

B-LED B1461-S instructions

B-LED

B-LED B1461-S instructions

cocoweb NEWCASTLE installation instructions

cocoweb

cocoweb NEWCASTLE installation instructions

Rebel Light URZ3484-2 user manual

Rebel Light

Rebel Light URZ3484-2 user manual

Stahl 6521/5 Series operating instructions

Stahl

Stahl 6521/5 Series operating instructions

LANZINI INTEGRA instructions

LANZINI

LANZINI INTEGRA instructions

Chauvet Freedom Stick user manual

Chauvet

Chauvet Freedom Stick user manual

Beamz 150.518 user manual

Beamz

Beamz 150.518 user manual

MICA HID-25 manual

MICA

MICA HID-25 manual

Robus RMA02040-01 quick start guide

Robus

Robus RMA02040-01 quick start guide

Steren LAM-750 instruction manual

Steren

Steren LAM-750 instruction manual

CRX CRX3308A instruction manual

CRX

CRX CRX3308A instruction manual

LumX LM 30200 instruction manual

LumX

LumX LM 30200 instruction manual

Luxibel B Flood DL60 user manual

Luxibel

Luxibel B Flood DL60 user manual

Home Zone Security ES00942G user manual

Home Zone Security

Home Zone Security ES00942G user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.