Lumiring Technology LR-1C Series User manual

LRE-1CR
LRM-1CR
LR-1CB
LRE-1CRS
LR-1CBS
LR-1C Series
Standalone Access Solution
User Manual
VIDEO MANUAL
LR-1C Series

1
2
2
4
4
6
8
12
12
14
16
17
19
20
22
23
25
26
28
29
31
32
34
INTRODUCTION
FEATURES
MAIN SPECIFICATION
CARTON INVENTORY
INSTALLATION
JUMPER SETTINGS
CONNECTION DIAGRAMM
ADD MASTER CARD
ADD USER CARD
DELETE USER CARD
DELETE ALL USER CARDS
ADD BOSS CARDS
DELETE BOSS CARD
DELETE ALL BOSS CARDS
ADD SECURITY CARDS
DELETE SECURITY CARD
DELETE ALL SECURITY CARDS
CHANGE STAND-BY THEME
CHANGE REACTION THEME
CHANGE LOCK WORK TIME
AUTOMATIC CARD ADD MODE
POSSIBILITIES OF BOSS CARD
POSSIBILITIES OF SECURITY CARD
CONTENTS

INTRODUCTION
01
The LR-1C its series of standalone access controllers with dier-
ent features: embed rd reader, embed NO-TOUCH button, em-
bed Radio Receiver 433 Mhz etc. All standalone controllers from
this series have RGB Lumiring indicator which used for work with
Lumiring menu.
By Lumiring Menu customer can:
ADD USER CARDS (1-2000)
DELETE ONE USER CARD
DELETE ALL USER CARDS
ADD BOSS CARDS (1-10)
DELETE ONE BOSS CARD
DELETE ALL BOSS CARDS
ADD SECURITY CARDS (1-3)
DELETE ONE SECURITY CARD
DELETE ALL SECURITY CARDS
CHOOSE STAND-BY INDICATION THEME (1-4)
CHOOSE REACTION INDICATION THEME (1-4)
CHOOSE TIME FOR LOCK WORK (1-255 s)
SET CONTROLLER TO CARD AUTO ADD MODE
All this work users can do without any tools in any time if have in
hand only MASTER CARD. Master cards must be set at rst system
start or after full hardware reset. One controller can support up
to 3 master cards.

FEATURES
MAIN SPECIFICATION
02
Static protection.
Reverse power protection.
Power protection.
Waterproof coat, conforms to IP 56 (IP65*)
Industrial grade components.
Security screw.
Safe wall mount.
Autodetect Wiegand 26 / 34 bits.
Full color RGB ring indicator.
4 Stand-By indication themes.
4 Work indication themes.
Low temperature resistance ( -30 C).
3 Lock work modes.
* By special order device will be made without terminal block with cable.
Memory: 2048 codes (special version up to
15 000)
Memory type: EEPROM, non-volatile
Critical event protection: Watch Dog, Power On Reset
Relay NC/NO: 1 (Control mode:Trigger, Pulse,
Monostable)
Relay operation time
control: 1-255 seconds, 3 seconds default
Relay Specication: 2A - continuous operation; 10A -
pulse mode
Door control input: 1 (Door not closed control, Breaking
open control)

03
Exit button input: 1 (Free/Card entry switching by long
press - 10 seconds)
Alarm out: 1 0,5A max
Power supply: 9-24VDC
Indicator: RGB light ring & Beeper
Visual themes: 4 stand-by, 4 reaction
Reader frequency: 125kHz or 13.56Mhz (option)
Standard 125kHz: EMMARINE
Standard 13.56MHz: ISO14443A
Reading range 125kHz: 6-12cm
Reading range
13.56MHz: 3-8cm
Supported Tage 125kHz: EM 4001 / EM 4012 / HID ISOProx II /
HID ProxCard II / TEMIC
Power Consumption: < 1W
Communication
Interface:
Autodetect Wiegand 26-34 bits /
W-BUS
If you need more detail specication for each device please
visit our site or download catalogue:
WEBSITE CATALOGUE

CARTON INVENTORY
INSTALLATION
04
Wall Anchors
Fast diode 1N4973
Self Tapping Screws
Allen wrench key Jumper connector
Security screw
LRE-1CR
LRM-1CR
LR-1CB
LRE-1CRS
LR-1CBS
Reader options
Remove the back cover from the unit.
Drill 4( A, B, C, D) holes or 2 any diagonal holes.
Put the supplied wall anchor in holes.
Put connection cable through cable window in back cover.
Fix the back cover rmly on the wall with 4 at head screws.
Attach wires in cable to terminal block by connection diagram.
Set necessary settings by jumpers.
Attach unit to the back cover and x by supplied security screw.
Power on device.

JUMPER SETTINGS
05

JUMPER SETTINGS
06
X1 JUMPER SETTINGS & SW1 DIP-SWITCH SETTINGS.
RELAY WORK MODES
JUMPER SET DIP SWITCH SETTING
1-2 OFF
3-4 OFF
1 -OFF
2 -OFF
Trigger mode
(default)
1-2 ON
3-4 OFF
1 -ON
2 -OFF Bistable mode
1-2 OFF
3-4 ON
1 -OFF
2 -ON
Monostable
mode
1-2 ON
3-4 ON
1 -ON
2 -ON Reserved
READER INTERFACE SETTINGS
JUMPER SET DIP SWITCH SETTING
7-8 OFF 3 -OFF W-BUS
(default)
7-8 ON 3 -ON Wiegand 26-34
AutoDetect
RELAY OUTPUT SETTINGS
JUMPER SET DIP SWITCH SETTING
9-10 OFF 4 -OFF Normally open
relay (default)
9-10 ON 4 -ON Normally closed
relay

07
DOOR CONTROL SETTINGS
JUMPER SET DIP SWITCH SETTING
11-12 OFF Without door control
sensor (default)
11-12 ON With door
sensor
HARDWARE RESET
JUMPER SET DIP SWITCH SETTING
4-6 OFF 6-OFF Work mode
(default)
4-6 ON 6-ON Hardware
reset

08
CONNECTION DIAGRAMM
LRE-1CR / LRM-1CR
ALTERNATIVE DIAGRAM FOR CONNECT
3RD PARTY READER (6 WIRES)

09
JUMPER SETTINGS IN THIS MODE
LR-1CB
FIRE ALARM FUNCTION:
This input used for connection to the re alarm system.
When the re alarm system emits an alarm the door shall be
opened in accordance with the rules on safety and security.

10
LRE-1CRS
DC SIREN FUNCTION:
This output used for connection to the alarm siren. If door
was open without card or not from EXIT button. Controller
Turn-ON alarm mode and switch DC Alarm out to closed
position.
Commutating ability for alarm out: 0,7A 12V
Door control sensor must be installed.
DOOR CONTROL SETTINGS
JUMPER SET SETTING
11-12 ON With door control
sensor
NOTE:
External reader
must have 5-wire
interface Wiegand
26 - 34 or W-BUS.
Controller auto-
matic detect which
type of Wiegand
have external
reader.

11
LR-1CBS

12
Power-on the device.
If it is the rst start of the device, the device will start automatically
in Master cards add mode.
Indication in this mode: BLINK BLUE RING and BEEP sound each
3 seconds.
Tap&back the RFID card/tag which you want to use like a Master
card to the reader. If the card is added successfully - the reader will
notify by changing of indication to GREEN RING with BEEP sound
and then it will return to BLUE RING and BEEP sound each 3 sec-
onds. To exit from this mode it is enough to bring already made
Master Card to the reader.
If you want to add more Master cards for this device - you must
swipe each card to the reader one by one. You can add up to 3
Master cards. After you add three Master cards the device will re-
start in the main working mode with default settings.
If you want to add Master card to the existing system please see
the chapter HARDWARE RESET.
Power-on the device.
To enter to Lumiring menu tap&hold Master card to the reader
and wait for three times card reading. Reader will inform about
each reading by BLUE RING indication and BEEP sounds. After third
reading remove Master card from the reader. Controller enter into
main menu. When the rst sector of the ring light up green color
you must tap&back Master card – the indication of the rst sector
will change to the blinking green. Now you can add User cards one
by one - tap&back each card to the reader. For each successfully
added card, the reader will inform by change indication to GREEN
RING and BEEP sound. If you try to add the card, which controller
ADD MASTER CARD
ADD USER CARD

13
already has in its memory, the reader will inform you about this by
changing of the indication to RED RING and BEEP sound.
To exit from this menu, you must tap&back Master card to the
reader one time. Wait for the reader changes the indication to
BLUE RING and tap&back Master card again. The controller will exit
from menu to the main working mode. The reader must change
indication to stand-by mode.
If you want to exit from this User menu to the main working mode
without adding any cards you must tap&back Master card 3 times
to the reader and wait until the reader changes the indication to
Blue ring and tap&back Master card one time again. The controller

14
will exit from menu to the main working mode. The reader must
change indication to stand-by mode.
To the main work mode controller will exit automatically after 30
seconds timeout from any menu.
Power-on the device.
To enter to Lumiring menu tap&hold Master card to the reader
and wait for three times card reading. Reader will inform about
each reading by BLUE RING indication and BEEP sounds. After
third reading remove Master card from the reader. Controller en-
ter into main menu. When the rst sector of the ring light up green
color you must tap&back Master card twice – the indication of the
rst sector will change to the blinking red. Now you can delete User
cards taking them to the reader one by one. For each successfully
deleted card the reader will notify of this changing of the indication
by RED RING and BEEP sound.
If you try to delete the card which controller has not got in its mem-
ory, the reader will notify you of this changing of the indication by
RED RING and BEEP-BEEP sound.
To exit from this menu, you must tap&back Master card to the
reader one time. Wait for the reader changes the indication to
BLUE RING and tap&back Master card again. The controller will exit
from menu to the main working mode. The reader must change
indication to stand-by mode.
DELETE USER CARD

15
If you want to exit from this User menu to the main working mode
without adding any cards you must tap&back Master card 2 times
to the reader and wait until the reader changes the indication to
Blue ring and tap&back Master card one time again. The controller
will exit from menu to the main working mode. The reader must
change indication to stand-by mode.
To the main work mode controller will exit automatically after 30
seconds timeout from any menu.

16
Power-on the device.
To enter to Lumiring menu tap&hold Master card to the reader
and wait for three times card reading. Reader will inform about
each reading by BLUE RING indication and BEEP sounds. After
third reading remove Master card from the reader. Controller
enter into main menu. When the rst sector of the ring light up
green color you must tap&back Master card twice – the indication
of the rst section will change to the blinking red. Now you must
to tap&hold Master card to the reader. The rst sector changes
into red color. Now you see countdown timer, which inform you
about starting of the deleting process. If you do not want to delete
all User cards, remove master card from the reader. If you want to
delete all User cards, hold master card near the reader and wait for
nishing countdown timer. When the countdown timer will nish
you can remove master card from the reader. The device is back
to the main menu.
DELETE ALL USER CARDS

ADD BOSS CARDS
17
To return to the main working mode you must wait when the
reader changes the indication to Blue ring and tap@back Master
card again. The controller will exit from menu to the main working
mode. The reader must change indication to stand-by mode.
To the main work mode controller will exit automatically after 30
seconds timeout from any menu.
Power-on the device.
To enter to Lumiring menu tap&hold Master card to the reader
and wait for three times card reading. Reader will inform about
each reading by BLUE RING indication and BEEP sounds. After
third reading remove Master card from the reader. Controller en-
ter into main menu. When the second sector of the ring light up
green color you must tap&back Master card – the indication of the
second sector will change to the blinking green. Now you can add
Boss cards one by one taking each card to the reader. For each
successfully added card, the reader will change the indication by
GREEN RING and BEEP sound. If you try to add the card, which
controller already has in its memory, the reader will notify you
about this changing of the indication by RED RING and BEEP-BEEP
sound. To exit from this menu, you must tap&back Master card to
the reader one time. Wait for the reader changes the indication to
BLUE RING and tap&back Master card again. The controller will exit

18
from menu to the main working mode. The reader must change
indication to stand-by mode.
If you want to exit from this User menu to the main working mode
without adding any cards you must tap&back Master card 3 times
to the reader and wait until the reader changes the indication to
Blue ring and tap&back Master card one time again. The controller
will exit from menu to the main working mode. The reader must
change indication to stand-by mode.
To the main work mode controller will exit automatically after 30
seconds timeout from any menu.
This manual suits for next models
5
Table of contents