Features
1. Fast oral temperature measurement in approximately 10 seconds.
2. Very sensitive unit; best for quick oral and rectal measurement.
3. Easy to read digital LCD (Liquid Crystal Display).
4. Flexiblesofttiptsnaturallyundertongueorunderarm.Won’tpokeorhurt.Flexibleprobeconforms
todifferentmouths.
5. Compact, accurate and durable LSI (Large Scale Integration) unit.
6. Ifthethermometerisinadvertentlyleftonaftertemperaturestabilization,itwillautomaticallyshutoffin
about 10 minutes.
7. Small,lightweightunit.Universaluseforthewholefamily.
8. Lesshazardousthanmercuryglassthermometers.
9. Lowbatteryindicator:whenthesymbol“ ”appears,thebatteryneedstobereplaced.
10.Thisunitiswaterproof.
Parts Description
Specications
Range 90°F ~ 109.3°F (32.0°C ~ 42.9°C)
< 90.0°F (32.0°C) displays Lo°F (°C)
> 109.9°F (42.9°C) displays Hi°F (°C)
Resolution 0.1° F (°C)
Accuracy ±0.2°F(93.2°Fto107.6°F)±0.4°F(otherrange)
 ±0.1°C(34.0°Cto42.0°C)±0.2°C(otherrange)
Display LCD (Liquid Crystal Display) 3 ½ digits
Battery (included Micro alkaline battery 192.LR41.1 5.5V
PowerConsumption 0.15milliwattsinmeasurementmode
BatteryLife >200hourscontinuousoperation
Dimensions 5.28 in x .98 in x .47 in (134 mm x 25 mm x 12 mm)
Weight Approximately0.03lb(14g)includingbattery
Beeper Approximately8secondssoundsignalwhenpeaktemperatureisreached
Memory Built-in memory enables display of previously measured value
Operation Environment Temperature 50°F ~ 95°F (10°C ~ 35°C )
Humidity 30% ~ 75% RH
Storage Environment Temperature 13°F ~ 140°F (-25°C ~ 60°C )
GuaranteeofQuality CerticationISO13485
Conformity EN12470-3, EN60601-1
ProductClassication TypeBF equipment
Precautions — Care and Maintenance
1. Donotboiltheprobe.Cleanthethermometerbywipingitwithaclean,drycloth,anddisinfectthe
probewithisopropylalcohol.
2. Donotdropthethermometerorexposeittoheavyshock.Thethermometerisnotshockproof.
3. Donotbendorbitetheprobe.
4. Donotstorethethermometerindirectsunlight,hightemperature,highhumidity,orinadustyenviron-
ment. Performance may be degraded.
5. Stopusingthethermometerifitoperateserraticallyorifthedisplaymalfunctions.
6. Keepthermometeroutofthereachofchildrenandalwayssupervisechildrenduringmeasurement.
7. Cleanthethermometerprobebeforestoring.
8. Donotdisassemblethethermometerexcepttoreplacethebattery.
9. Ifthethermometerhasbeenstoredatbelow-freezingtemperatures,allowittowarmnaturallytoroom
temperature before use.
10.Thermometerperformancemaybedegradedifoperatedorstoredoutsiderecommendedtemperature
andhumidityrangesshowninSpecicationssectionabove,orifthepatient’stemperatureisbelow
ambient (room) temperature.
Battery Replacement
1. Whenthesymbol“ ”appears,thebatteryneedstobereplaced.
2. Pullthebatterycoveroffinthedirectionshownbelow.
3. Ifnecessary,useapointedobjectsuchasatoothpickorinsulated
probetogentlyprythebatterycoverandbatteryloose;avoidusing
asharpmetalobjectforthisoperation.
4. Placeanew1.55VDCbutton-sizebattery,type192.LR41or
equivalent,inthebatterychamberwithnegativeside(–)upand
positiveside(+)down.
5. Replaceandfastenthebatterycoversecurely.
Warning: Discard the old battery carefully, out of the reach of children. Swallowing the battery
could be harmful or fatal. If the battery is inadvertently swallowed, contact a hospital immedi-
ately to have it removed. Do not dispose of the battery in a re. It may explode.
Model L2214
Digital Thermometer
INSTRUCTIONS FOR USE
Please read carefully before using
How to Use the Thermometer
1. DepresstheON/OFFbutton.Thedisplaywillshow or .
2. ReleasetheON/OFFbutton.ThedisplaywillshowLo°F(Lo°C)with°F(°C)ashing.
2. Disinfecttheprobewithisopropylalcohol.Seeinstructionsbelowtoplacetheprobeinanappropriate
position (oral, axillary, or rectal).
3. Oncethedegreesign(°For°C)hasstoppedashing,usuallywithin15-30seconds,thecorrecttem-
peratureisshown.Thetemperatureshowingwillnotchangeafterthe°F(°C)hasstoppedashing.
4. Thethermometerwillautomaticallyturnoffinapproximately9minutes.However,toprolongbattery
life,itisbesttoturnthethermometeroffbypressingtheON/OFFbuttononcethetemperaturehas
been noted.
Special Features
NormalTemperatureAlarm:Whenthepeaktemperaturehasregisteredandisreadytoread,analarmwill
sound.The“NormalTemperature”alarm(10beeps)willsoundforapproximately8seconds.
FeverAlarm:Whenthepeaktemperaturehasregisteredhigherthan99.5°F(37.5°C),thefeveralarm
(approximately10secondsofquickbeeps)willsound.
AutomaticLastTemperatureRecall:WhentheON/OFFbuttonispressedtoactivatethethermometer,
display188.8willchangetoshowthelastmeasuredtemperaturevalue,thenreturnto“readytomeasure”
mode.
FahrenheitandCelsiusSwitchable:TheFahrenheitorCelsiusmodecanbeswitchedbypressingthe
ON/OFFbuttonwithintherst5seconds.
Note: Always disinfect the thermometer before use.
Note: In Step 2, if the room temperature is greater than 90.0°F (32.0°C), it will be displayed rather than
Lo°F (°C).
Note: In Step 3, you may put a sanitary plastic probe shield on the sensor tip to help prevent cross
infection and contamination. Use of the probe cover may result in a 0.2°F (0.1°C) difference from actual
temperature. Dispose of any used probe shield and store the thermometer in a safe place.
Reliable Methods to Measure Temperature
Measuring Body Temperature:Changeinbodytemperatureisoneofthemostimportantindicatorsof
illness.Itisimportantthataccuratetemperaturesbetaken.Eventhoughthedigitalthermometerisused
insimilarmannertotheglassthermometer,instructionsforuseofthisthermometermustbefollowed
closely,andthepersontakingthetemperaturemustunderstandbodytemperature.
Body Temperature:Apersons’sbodytemperatureisusuallyseveraltenthstoonefulldegreelowerin
themorningthaninthelateafternoon.Therefore,ifyourtemperatureinthemorningis97.9°F(36.6°C),it
couldbe98.4°F(36.9°C)ormoreinthelateafternoonandstillbenormal.Todeterminewhatyournormal
bodytemperatureis,youshouldtakeyourtemperaturebothintheearlymorningandlateafternoonover
severaldays.Childrenhavethesamenormaltemperaturerangeasadults.Afeverborbothchildrenand
adultsintypicallydenedasanoraltemperaturehigherthan99.5°F(37.5°C).Exercise,excessivecloth-
ing,hotbath,hotweather,andwarmfoodanddrinkcancausemildelevationsofupto100.4°F(38°C)
inoraltemperature.Ifyoususpectoneofthesetobethecauseofanelevatedreading,eliminatethe
possiblecauseandretakethetemperatureinhalfanhour.
Oral Use
Placetheprobewellunderthepatient’stongue.Instructthepatientto
keeptheirmouthclosedwhilethethermometerismeasuring.Anormal
oraltemperatureisusuallyconsideredtobebetween96.8°F–98.6°F
(36.0°C–37.5°C).
Rectal Use
Ifrectaltemperatureisrecommendedbyyourdoctor,youmayuseaprobecover.Insertthermometer
tipintotheprobecover.Lubricatetheprobecoverwithawatersolublejellyforeasierinsertion.Donot
usepetroleumjelly.Inserttipofprobenomorethan½inchintorectum.Stopifyoumeetanyresistance.
Thesensingdeviceisontheverytipoftheprobeandthereisnoneedtoinserttheprobedeepinto
therectum.Rectaltemperatureisusuallyapproximately1.0°F–2.0°F(0.5°C–1.0°C)higherthanoral
temperature.
Axillary Use (Armpit)
Wipearmpitwithadrytowel.Placeprobeinthepatient’sarmpitandkeepthepatient’sarmpressedrmly
againsttheirside.Axillarytemperatureisusuallyapproximately1.0°F–2.0°F(0.5°C–1.0°C)lowerthan
oraltemperature.Note:Inordertoachievebetteraxillarytemperaturemeasurementresult,aminimum
measuringtimeof3-5minutesisrecommendedregardlessofthebeepsound.
Note: Children should be attended by an adult during the entire temperature recording process. After
use, the digital thermometer should be stored in a safe place, out of the reach of children. If you compare
temperatures between two thermometers, it is possible to have two different readings, even if both
thermometers are within their accuracy tolerances. Differences in how you take each reading and the
thermometer’s tolerance range can account for nearly 0.2°F (0.1°C) variability.
Remember: Find your normal temperature and watch for changes.
Cleaning Instructions
Tocleanthethermometer,washthetipwithasolutionofmilddetergentandcoolwater.Todisinfectthe
thermometer,wipethesensorandlowerstemwithacleanclothdippedinisopropylalcohol.
Limited warranty
Thisthermometerisguaranteedagainstmanufacturer’sdefectsundernormalhouseholduseforoneyear
fromthedateofpurchase.Followingtheinstructionscloselywillensureyearsofdependableoperation.
Ifthethermometerdoesnotfunctionproperly,rstcheckthebatteryandreplaceitifnecessary(see
instructionsabove).RepairDepartment:1-800-672-8293.
ManufacturedforGFHealthProducts,Inc.
Atlanta, Georgia 30360
©2010GFHealthProducts,Inc.
MadeinChina
www.grahameld.com

Other Lumiscope Thermometer manuals

Lumiscope 2215 User manual

Lumiscope

Lumiscope 2215 User manual

Lumiscope 2220 User manual

Lumiscope

Lumiscope 2220 User manual

Lumiscope 2216 User manual

Lumiscope

Lumiscope 2216 User manual

Popular Thermometer manuals by other brands

prologue K0389 instruction manual

prologue

prologue K0389 instruction manual

Dwyer Instruments IR2 series manual

Dwyer Instruments

Dwyer Instruments IR2 series manual

Vick V977-LA use and care manual

Vick

Vick V977-LA use and care manual

Oregon Scientific RMR132 user manual

Oregon Scientific

Oregon Scientific RMR132 user manual

Extech Instruments IR250 user manual

Extech Instruments

Extech Instruments IR250 user manual

SICK TCT operating instructions

SICK

SICK TCT operating instructions

VOLTCRAFT PL-120 T2 - V07-10 manual

VOLTCRAFT

VOLTCRAFT PL-120 T2 - V07-10 manual

Pic Solution ThermoDiary HEAD Instructions for use

Pic Solution

Pic Solution ThermoDiary HEAD Instructions for use

Fluke Comark C21 Operator's manual

Fluke

Fluke Comark C21 Operator's manual

Exergen TemporalScanner TAT-5000S-RS232-CORO Operator's manual

Exergen

Exergen TemporalScanner TAT-5000S-RS232-CORO Operator's manual

Hart Sceintific 1506 Operator's manual

Hart Sceintific

Hart Sceintific 1506 Operator's manual

Omron MC-246 quick start guide

Omron

Omron MC-246 quick start guide

Auriol Z31269 Operation manual

Auriol

Auriol Z31269 Operation manual

ADE WS 1832 operating manual

ADE

ADE WS 1832 operating manual

YOKOGAWA TX1001 user manual

YOKOGAWA

YOKOGAWA TX1001 user manual

Balluff BTS M30E0-UUI-H0001-S04G user guide

Balluff

Balluff BTS M30E0-UUI-H0001-S04G user guide

WIKA R52.100 operating instructions

WIKA

WIKA R52.100 operating instructions

BROWN 185109 Operation manual

BROWN

BROWN 185109 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.