manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lumiscope
  6. •
  7. Thermometer
  8. •
  9. Lumiscope L2214 User manual

Lumiscope L2214 User manual

Other Lumiscope Thermometer manuals

Lumiscope 2220 User manual

Lumiscope

Lumiscope 2220 User manual

Lumiscope 2215 User manual

Lumiscope

Lumiscope 2215 User manual

Lumiscope 2216 User manual

Lumiscope

Lumiscope 2216 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

L2214-INS-LAB-RevD10
Features
1. Fast oral temperature measurement in approximately 10 seconds.
2. Very sensitive unit; best for quick oral and rectal measurement.
3. Easy to read digital LCD (Liquid Crystal Display).
4. Flexiblesofttiptsnaturallyundertongueorunderarm.Won’tpokeorhurt.Flexibleprobeconforms
todifferentmouths.
5. Compact, accurate and durable LSI (Large Scale Integration) unit.
6. Ifthethermometerisinadvertentlyleftonaftertemperaturestabilization,itwillautomaticallyshutoffin
about 10 minutes.
7. Small,lightweightunit.Universaluseforthewholefamily.
8. Lesshazardousthanmercuryglassthermometers.
9. Lowbatteryindicator:whenthesymbol“ ”appears,thebatteryneedstobereplaced.
10.Thisunitiswaterproof.
Parts Description
Specications
Range 90°F ~ 109.3°F (32.0°C ~ 42.9°C)
< 90.0°F (32.0°C) displays Lo°F (°C)
> 109.9°F (42.9°C) displays Hi°F (°C)
Resolution 0.1° F (°C)
Accuracy ±0.2°F(93.2°Fto107.6°F)±0.4°F(otherrange)
 ±0.1°C(34.0°Cto42.0°C)±0.2°C(otherrange)
Display LCD (Liquid Crystal Display) 3 ½ digits
Battery (included Micro alkaline battery 192.LR41.1 5.5V
PowerConsumption 0.15milliwattsinmeasurementmode
BatteryLife >200hourscontinuousoperation
Dimensions 5.28 in x .98 in x .47 in (134 mm x 25 mm x 12 mm)
Weight Approximately0.03lb(14g)includingbattery
Beeper Approximately8secondssoundsignalwhenpeaktemperatureisreached
Memory Built-in memory enables display of previously measured value
Operation Environment Temperature 50°F ~ 95°F (10°C ~ 35°C )
Humidity 30% ~ 75% RH
Storage Environment Temperature 13°F ~ 140°F (-25°C ~ 60°C )
GuaranteeofQuality CerticationISO13485
Conformity EN12470-3, EN60601-1
ProductClassication TypeBF equipment
Precautions — Care and Maintenance
1. Donotboiltheprobe.Cleanthethermometerbywipingitwithaclean,drycloth,anddisinfectthe
probewithisopropylalcohol.
2. Donotdropthethermometerorexposeittoheavyshock.Thethermometerisnotshockproof.
3. Donotbendorbitetheprobe.
4. Donotstorethethermometerindirectsunlight,hightemperature,highhumidity,orinadustyenviron-
ment. Performance may be degraded.
5. Stopusingthethermometerifitoperateserraticallyorifthedisplaymalfunctions.
6. Keepthermometeroutofthereachofchildrenandalwayssupervisechildrenduringmeasurement.
7. Cleanthethermometerprobebeforestoring.
8. Donotdisassemblethethermometerexcepttoreplacethebattery.
9. Ifthethermometerhasbeenstoredatbelow-freezingtemperatures,allowittowarmnaturallytoroom
temperature before use.
10.Thermometerperformancemaybedegradedifoperatedorstoredoutsiderecommendedtemperature
andhumidityrangesshowninSpecicationssectionabove,orifthepatient’stemperatureisbelow
ambient (room) temperature.
Battery Replacement
1. Whenthesymbol“ ”appears,thebatteryneedstobereplaced.
2. Pullthebatterycoveroffinthedirectionshownbelow.
3. Ifnecessary,useapointedobjectsuchasatoothpickorinsulated
probetogentlyprythebatterycoverandbatteryloose;avoidusing
asharpmetalobjectforthisoperation.
4. Placeanew1.55VDCbutton-sizebattery,type192.LR41or
equivalent,inthebatterychamberwithnegativeside(–)upand
positiveside(+)down.
5. Replaceandfastenthebatterycoversecurely.
Warning: Discard the old battery carefully, out of the reach of children. Swallowing the battery
could be harmful or fatal. If the battery is inadvertently swallowed, contact a hospital immedi-
ately to have it removed. Do not dispose of the battery in a re. It may explode.
Model L2214
Digital Thermometer
INSTRUCTIONS FOR USE
Please read carefully before using
How to Use the Thermometer
1. DepresstheON/OFFbutton.Thedisplaywillshow or .
2. ReleasetheON/OFFbutton.ThedisplaywillshowLo°F(Lo°C)with°F(°C)ashing.
2. Disinfecttheprobewithisopropylalcohol.Seeinstructionsbelowtoplacetheprobeinanappropriate
position (oral, axillary, or rectal).
3. Oncethedegreesign(°For°C)hasstoppedashing,usuallywithin15-30seconds,thecorrecttem-
peratureisshown.Thetemperatureshowingwillnotchangeafterthe°F(°C)hasstoppedashing.
4. Thethermometerwillautomaticallyturnoffinapproximately9minutes.However,toprolongbattery
life,itisbesttoturnthethermometeroffbypressingtheON/OFFbuttononcethetemperaturehas
been noted.
Special Features
NormalTemperatureAlarm:Whenthepeaktemperaturehasregisteredandisreadytoread,analarmwill
sound.The“NormalTemperature”alarm(10beeps)willsoundforapproximately8seconds.
FeverAlarm:Whenthepeaktemperaturehasregisteredhigherthan99.5°F(37.5°C),thefeveralarm
(approximately10secondsofquickbeeps)willsound.
AutomaticLastTemperatureRecall:WhentheON/OFFbuttonispressedtoactivatethethermometer,
display188.8willchangetoshowthelastmeasuredtemperaturevalue,thenreturnto“readytomeasure”
mode.
FahrenheitandCelsiusSwitchable:TheFahrenheitorCelsiusmodecanbeswitchedbypressingthe
ON/OFFbuttonwithintherst5seconds.
Note: Always disinfect the thermometer before use.
Note: In Step 2, if the room temperature is greater than 90.0°F (32.0°C), it will be displayed rather than
Lo°F (°C).
Note: In Step 3, you may put a sanitary plastic probe shield on the sensor tip to help prevent cross
infection and contamination. Use of the probe cover may result in a 0.2°F (0.1°C) difference from actual
temperature. Dispose of any used probe shield and store the thermometer in a safe place.
Reliable Methods to Measure Temperature
Measuring Body Temperature:Changeinbodytemperatureisoneofthemostimportantindicatorsof
illness.Itisimportantthataccuratetemperaturesbetaken.Eventhoughthedigitalthermometerisused
insimilarmannertotheglassthermometer,instructionsforuseofthisthermometermustbefollowed
closely,andthepersontakingthetemperaturemustunderstandbodytemperature.
Body Temperature:Apersons’sbodytemperatureisusuallyseveraltenthstoonefulldegreelowerin
themorningthaninthelateafternoon.Therefore,ifyourtemperatureinthemorningis97.9°F(36.6°C),it
couldbe98.4°F(36.9°C)ormoreinthelateafternoonandstillbenormal.Todeterminewhatyournormal
bodytemperatureis,youshouldtakeyourtemperaturebothintheearlymorningandlateafternoonover
severaldays.Childrenhavethesamenormaltemperaturerangeasadults.Afeverborbothchildrenand
adultsintypicallydenedasanoraltemperaturehigherthan99.5°F(37.5°C).Exercise,excessivecloth-
ing,hotbath,hotweather,andwarmfoodanddrinkcancausemildelevationsofupto100.4°F(38°C)
inoraltemperature.Ifyoususpectoneofthesetobethecauseofanelevatedreading,eliminatethe
possiblecauseandretakethetemperatureinhalfanhour.
Oral Use
Placetheprobewellunderthepatient’stongue.Instructthepatientto
keeptheirmouthclosedwhilethethermometerismeasuring.Anormal
oraltemperatureisusuallyconsideredtobebetween96.8°F–98.6°F
(36.0°C–37.5°C).
Rectal Use
Ifrectaltemperatureisrecommendedbyyourdoctor,youmayuseaprobecover.Insertthermometer
tipintotheprobecover.Lubricatetheprobecoverwithawatersolublejellyforeasierinsertion.Donot
usepetroleumjelly.Inserttipofprobenomorethan½inchintorectum.Stopifyoumeetanyresistance.
Thesensingdeviceisontheverytipoftheprobeandthereisnoneedtoinserttheprobedeepinto
therectum.Rectaltemperatureisusuallyapproximately1.0°F–2.0°F(0.5°C–1.0°C)higherthanoral
temperature.
Axillary Use (Armpit)
Wipearmpitwithadrytowel.Placeprobeinthepatient’sarmpitandkeepthepatient’sarmpressedrmly
againsttheirside.Axillarytemperatureisusuallyapproximately1.0°F–2.0°F(0.5°C–1.0°C)lowerthan
oraltemperature.Note:Inordertoachievebetteraxillarytemperaturemeasurementresult,aminimum
measuringtimeof3-5minutesisrecommendedregardlessofthebeepsound.
Note: Children should be attended by an adult during the entire temperature recording process. After
use, the digital thermometer should be stored in a safe place, out of the reach of children. If you compare
temperatures between two thermometers, it is possible to have two different readings, even if both
thermometers are within their accuracy tolerances. Differences in how you take each reading and the
thermometer’s tolerance range can account for nearly 0.2°F (0.1°C) variability.
Remember: Find your normal temperature and watch for changes.
Cleaning Instructions
Tocleanthethermometer,washthetipwithasolutionofmilddetergentandcoolwater.Todisinfectthe
thermometer,wipethesensorandlowerstemwithacleanclothdippedinisopropylalcohol.
Limited warranty
Thisthermometerisguaranteedagainstmanufacturer’sdefectsundernormalhouseholduseforoneyear
fromthedateofpurchase.Followingtheinstructionscloselywillensureyearsofdependableoperation.
Ifthethermometerdoesnotfunctionproperly,rstcheckthebatteryandreplaceitifnecessary(see
instructionsabove).RepairDepartment:1-800-672-8293.
ManufacturedforGFHealthProducts,Inc.
Atlanta, Georgia 30360
©2010GFHealthProducts,Inc.
MadeinChina
www.grahameld.com