lumishore LUMI-LINK COMMAND CENTER User manual

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com 1
45-0137 - Rev 3
COMMAND CENTER
Installaon Guide
Please read the following pages before aempng installaon to ensure complete
understanding of the LUMISHORE Lumi-Link Command Center
PARTS INCLUDED
1 x DMX TERMINATOR 1 x FIELD INSTALL RJ45 IP67 COVER KIT
(39-0235)

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com 2
Lumi-Link Command Center Installation Instructions
Before you start…
Always ensure that the vessel’s power source and battery are disconnected or isolated prior to
installation.
A qualified professional should carry out both the electrical and mechanical installation.
The Lumi-Link Eos and / or Lux lighting system should be fully installed before connecting the
Lumi-Link Command Center.
The Lumi-Link Command Center must be mounted in a dry location and on a flat (not curved)
surface away from any sources of heat or vibration
The Lumi-Link Command Center works with the Lumi-Link Display and or compatible Multi-
function Displays (MFD). - check the compatibility of your MFD prior to installing the Lumi-Link
Command Center. The MFD may require a software update.
The Lumi-link Command center has an accessible SD card slot for future software upgrades.
When mounting, future access to this SD card slot should be taken into consideration.
Connection Options…
The Lumi-Link Command Center is a cross platform device. Via ethernet, it can connect to a single or
multiple MFD network, connect to a Lumishore Lumi-link display or be controlled by a smart
Phone/tablet (via Wi-Fi).
Compatible MFD’s include the following…
MFD COMPATABILITY
-Garmin (OneHelm Enabled)
-Raymarine –Axiom (Lighthouse Partner
App)
-Navico –Simrad (NSO EVO3 and EVO2,
NSS EVO3 and Go**), B&G (Zeus3 Glass
Helm, Zeus3 and Vulcan)
-Furuno (Models TBC)
The Lumi-link Display can be used if there are no MFD’s on the vessel or if additional access points
are required around the vessel. For full details of the Lumi-link Display see Lumi-Link Display
installation instructions.
Via an on-board Wi-Fi network (either through the MFD Wi-Fi or through the Lumi-Link Display on-
board Wi-Fi) the Lumi-link app can be controlled from a smart device. Full instructions for this are
included in the Lumi-Link Command Center user manual.
MFD COMPATABILITY
- Garmin (OneHelm Enabled)
- Raymarine - Axiom (Lighthouse Partner App)
- Navico - Simrad (NSO EVO3 and EVO2,
NSS EVO3 and Go**), B&G (Zeus3 Glass Helm,
Zeus3 and Vulcan)
- Furuno (Models TBC)

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
Single MFD Connection
Lumi-Link Display Connection
Multiple MFD/Lumi-link Display Device connection
Note: use a MFD manufacture specific Network expansion port –consult with your MFD installation
guide or contact a dealer for further advice.
www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
Lumi-Link Command Center Installation Instructions
Before you start…
Always ensure that the vessel’s power source and battery are disconnected or isolated prior to
installation.
A qualified professional should carry out both the electrical and mechanical installation.
The Lumi-Link Eos and / or Lux lighting system should be fully installed before connecting the
Lumi-Link Command Center.
The Lumi-Link Command Center must be mounted in a dry location and on a flat (not curved)
surface away from any sources of heat or vibration
The Lumi-Link Command Center works with the Lumi-Link Display and or compatible Multi-
function Displays (MFD). - check the compatibility of your MFD prior to installing the Lumi-Link
Command Center. The MFD may require a software update.
The Lumi-link Command center has an accessible SD card slot for future software upgrades.
When mounting, future access to this SD card slot should be taken into consideration.
Connection Options…
The Lumi-Link Command Center is a cross platform device. Via ethernet, it can connect to a single or
multiple MFD network, connect to a Lumishore Lumi-link display or be controlled by a smart
Phone/tablet (via Wi-Fi).
Compatible MFD’s include the following…
MFD COMPATABILITY
-Garmin (OneHelm Enabled)
-Raymarine –Axiom (Lighthouse Partner
App)
-Navico –Simrad (NSO EVO3 and EVO2,
NSS EVO3 and Go**), B&G (Zeus3 Glass
Helm, Zeus3 and Vulcan)
-Furuno (Models TBC)
The Lumi-link Display can be used if there are no MFD’s on the vessel or if additional access points
are required around the vessel. For full details of the Lumi-link Display see Lumi-Link Display
installation instructions.
Via an on-board Wi-Fi network (either through the MFD Wi-Fi or through the Lumi-Link Display on-
board Wi-Fi) the Lumi-link app can be controlled from a smart device. Full instructions for this are
included in the Lumi-Link Command Center user manual.
3

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
Connecting the Lumi-Link Command Center to the Lumi-Link Display or MFD.
For direct connection to the Lumishore Lumi-Link Display any standard ethernet network cable can
be used. Connection to the various brands of MFD’s are brand specific. The following diagrams show
the components required to connect the Lumi-Link Command Center to each brand.
The length of network cable depends on where the Lumi-link command centre has been installed
relative to the Display or MFD. Each MFD manufacturer offers different lengths of network cable,
check your installation length before ordering.
Lumishore supplies a Field install RJ45 IP67 cover to make your connections to the Lumi-link
Command Center waterproof. The cover should be used on all installations. Note: The internal
support may or may not be required depending on the type of Ethernet connector molding.
Field install IP67 RJ45 Cover Assembly
Lumi-Link Display –Use standard Ethernet Cat5e Cable
4
PLEASE REFER TO RJ45 IP67 ASSEMBLY
INSTRUCTIONS SUPPLIED WITH RJ45
COVER KIT (39-0235)

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
5
Garmin MFD Install - Use Garmin Conversion Cable PN: 60-0372 and Garmin Network Cable.
(Note: the Garmin Conversion cable Must be installed –only use Garmin network cables)
Raymarine MFD Install - Use Raynet to RJ45 Cable, Raymarine PN: A80151

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
Simrad & B&G MFD Install - Use Navico Conversion cable PN: 60-0373
Furuno MFD Install –Use Standard Ethernet Cat5e cable
6

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
7
Lumi-Link Command Center Connections
The Command Center uses a proprietary form of DMX to communicate between the lights and
controller. Whilst Lumishore EOS lights can be controlled by any DMX controller (with limited
feature set), the Lumi-Link Command Center can only be used to control Lumishore products.
The Lumi-Link Command Center is plugged into the first Driver, Hub or Light Module in the series.
The installation is terminated using a DMX Terminator plugged into the last light, driver, hub or
module in the series. (see example diagrams on the following pages)
• The Lumi-Link Command Center is for 12/24volt DC operation (10-31volt input). Under no
circumstances should the Controller be connected directly to Mains AC voltage.
• Always use a suitable fuse or circuit breaker to protect the Lumi-Link Command Center and each
element of the system.
3 Pin M12 Lumi-Link Data out connector:
1. Using Lumi-Link DMX cable extensions connect one end to the 3 pin connector on the back of the
Lumi-Link Command Center. Connect the other end to the first light, driver, hub or module in the
series.
2. Use a Lumi-link DMX extension cable to link the next Driver or lighting module. Do not cut or
extend the DMX link cable.
Pre-molded Lumi-link DMX cables are available in 1 meter, 5 meter and 15 meter lengths as
required. Multiple cables can be combined if a further distance is required.

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
3. Plug the supplied DMX terminator into the DMX output connector of the last light, driver or
module in the chain.
Sound to Light Connection:
A 3.5mm Jack Socket is included. Use a “Jack to Jack” cable or “Jack to Phono” cable as required to
plug the “Line out” from a stereo or iPad/iPhone.
For best results use a stereo output that has constant output irrespective of volume, i.e. when using
an iPad or iPhone use the line out rather than the headphone socket. That way the sensitivity of the
controller will not need continuous adjustment when changing volume.
3rd Party Trigger Input (Optional):
Contact Lumishore to discuss optional 3rd party triggers for Scenes and Zones.
EOS Underwater Light installation Example diagrams: -
8
60-0403
60-0404
60-0405

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
9

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com 10
System Diagram for Lumi-Link System including both EOS (underwater lights) and LUX (above
water Lights)…
Independent Switches (1,2)
Each LUX module can be controlled from independent momentary switches mounted in the room or
dash board. When pressed, the switch removes control from the Lumi-link command centre and
offers independent On/off control, dimming or pre-set colour selection. To let the Lumi-link
command centre regain control the associate zone should be powered off and on again at the MFD,
smart device or Lumi-Link display.
Mom Switch 1: ON/Off, Press and hold to Dim.
Mom Switch 2 (optional):Can be wired to control pre-set colours; Cold White, Mid White, Warm
White, Red, Blue, Green, Cyan, Magenta or alternatively wired to control Cold White, Mid White and
Warm White only.

www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 |(941) 405-3302 | Sales@LumishoreUSA.com
Lumi-Link Command Center - Status Leds
If power to the Lumi-Link Command Center is lost temporarily then the system may not fully
function until you exit to the Home screen on the MFD, and then re-select the Lumi-Link Screen.
If there are multiple MFDs in use, and one of the MFDs is used to access a set-up mode (e.g. Light
Set-Up), then the other MFDs will be locked out and will display a message. If this message is seen
then exit to the home screen. Once the set-up is completed the system can be used as normal.
Warranty
LUMISHORE Ltd warrants the Lumi-Link Command Center to be free from defects in workmanship
and materials for a period of two years, starting from the date of original purchase. Misuse, abuse,
improper installation, neglect, improper shipping, damage caused by disasters such as fire, flood,
and lightning, installation by unqualified personnel, unauthorized repair or modification will void this
warranty. For the avoidance of confusion and doubt, non-compliance with all installation,
maintenance and operating instructions in this document constitute non-conformance with
warranty terms.
11
Other manuals for LUMI-LINK COMMAND CENTER
1
Table of contents