TDT13UX-xx
Ver:1220AP
Optical power unit: dBm, mW optional
Buzzer alarm: ON, OFF optional
Number of channels: 0-100 optional
RF control mode: AGC, MGC optional
AGC offset: ±5dB optional
MGC attenuation: 0-15 optional
Set the equipment IP address
Set the subnet mask
Set the gateway
Reset to the default
Laser output optical power
Laser bias current
Internal temperature of the laser
Laser cooling current
Transmission channel numbers
Laser drive level
RF control mode
AGC offset (in AGC mode)
MGC attenuation (in MGC mode)
+5V monitoring voltage
-5V monitoring voltage
+24V monitoring voltage
Equipment wavelength
Serial number
Current internal temperature
Equipment IP address
Equipment subnet mask
Equipment gateway
Equipment MAC address
Equipment software version number
Set Laser Output Unit dBm
Set Buzzer Alarm ON
Set Channel Number XX
Set RF Control Mode AGC
Set AGC Ref XX dB
Set MGC ATT XX dB
Set IP Addr
Set Subnet Mask
Set Gate Way
Restore Factory Config
Laser Output xx dBm
Laser Bias xx mA
Laser Temp xx ℃
Tec Cooling xx A
RF Channel Number xx
Laser RF xx dBuV
RF Control Mode AGC
AGC Ref x dB
MGC ATT x dB
+5V Read x v
-5V Read x v
+24V Read x v
Wave Length 1310
S/N
BOX Temperature xx ℃
IP Address
Subnet Mask
Net Gateway
Mac
SoftWare Version
Laser level alarm: The default normal range is 80~110dBuV,
which can be set through the network management.
Laser temperature alarm: The default normal range is 25±10°C,
which can be set through the network management.
Laser bias current alarm: The default normal range is 20~90mA,
which can be set through the network management.
Output optical power alarm: The default normal range is 2 to 25 mW,
which can be set through the network management
Display Parameters, the second level submenu:
Set Parameters, the second level submenu:
Alarm Status, the second level submenu:
Laser RF
Laser Temp
Laser Bias
Laser Output