MODEL CEPS-36W INSTALLATION INSTRUCTIONS
1
LVS
LVS, Inc. 2555 Nicholson Street, San Leandro, CA 94577-4216
Phone: 510-352-9600 1-800-982-4587 Fax: 510-352-6707
Web: WWW.LVSCONTROLS.COM
LVS, Inc. warrants to the original purchaser/user for the published warranty period from the date of shipment that should LVS instruments or
equipment prove defecve by reason of improper workmanship or material, LVS will repair or replace the same equipment without charge.
This warranty does not cover defects or malfuncons arising from improper installaon, operaon or repair, or neglect, accident, or abuse. LVS
will honor its warranty provided the equipment has not been physically damaged or improperly installed or connected. To obtain warranty/re-
pair, the defecve product should be shipped freight prepaid within the warranty period to the address below. To the extent permied by
applicable law, all warranes extending beyond repair or replacement as described above are disclaimed, including the implied warranes of
merchantability and fitness for a parcular purpose. Where applicable law prohibits disclaimers or the implied warranes of merchantability
and fitness; those warranes are limited to 12 months from date of shipment. LVS provides a 90 day money back guarantee if equipment
does not perform in accordance with LVS published specificaons. The liability of LVS and its agents under all warranes is limited to repair and
replacement as described herein and under no circumstances shall there be liability for any other kind of loss, damage, or labor, either conse-
quenal or for injury to person or property or otherwise.
5-Year Limited Warranty
1. Make sure all connections are in accordance with the National Electrical Code and local regulations.
2. To reduce the risk of electric shock, disconnect both normal and emergency power supplies before servicing.
3. This product is suitable for use in dry or damp locations. Do not mount it near gas or electric heaters, air
outlets or other hazardous locations.
4. An unswitched AC power source is required (120-277VAC, 50/60Hz).
5. Use this product in 0ºC minimum 50ºC maximum ambient temperature
6. Do not attempt to service a sealed product. When malfunctioning, return to the manufacturer: LVS, Inc.
2555 Nicholson Street, San Leandro, CA 94577.
7. The use of accessory equipment is not recommended and may cause unsafe condition and void warranty.
8. Do not use this product for other than its intended use.
9. Installation and service should be performed only by qualified service personnel.
10. Equipment should be mounted in locations and at heights where it will not readily be subjected to
tampering by unauthorized personnel.
11. UL924 listed for both factory and field installation.
12. Do not attempt to service the batteries. A sealed, maintenance-free battery is used which is
not field-replaceable. Contact manufacturer for replacement guidelines.
13. Intended for use with LED, incandescent, fluorescent fixtures.
! IMPORTANT SAFEGUARDS !
SAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS
SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
Electrical Specfications
120/277VAC, 50/60Hz Sensing Input
120/277 60Hz Output
Max Output Power: 36W for Ambient Temp: 10C-55C
Max Output Power: 27W for Ambient Temp: 0C-10C
U
L
®
UL924 LISTED
C US

2
CAUTION:
MAKE SURE AC POWER IS OFF UNTIL INSTALLATION IS COMPLETE
OUTSIDE THE LUMINAIRE
LED test switch
CEPS-36W
NSTALLING THE CEPS-36W
The CEPS-36W can be mounted inside or outside (nearby or on top of) the luminaire.
3. INSTALLING THE LED TEST SWITCH (LTS)
Select a convenient location for the LTS so that it can be seen after installation.
Drill a 1/2"(12 mm) hole for mounting the LTS
INSIDE THE LUMINAIRE
CEPS-36W
LED test switch 1/2” K.O.

3
OPERATION
When AC power is applied, the LED test switch is illuminated, indicating that the batteries are being charged. When
AC power fails, the CEPS-36W will switches to emergency power, automatically illuminating the connected loads.
The LED test switch is switched off. When the AC power is restored the emergency module switches the system
back to normal mode and resumes battery charging. The minimum emergency operation time is 90 minutes. The
charging time for the full discharged battery is 24 Hours.
TESTING ANDMAINTENANCE
The following periodic tests are recommended to ensure the system is working:
1) Visually inspect the LED test switch (LTS) monthly. It should be solidly illuminated.
2) Conduct a 30 second discharge every month by disconnecting the AC input power.
3) Conduct a 90 minute discharge every month by disconnecting the AC input power.
AUTO TEST
The CEPS-36W has an Auto Test function which reduces the cost of manual testing:
1) Instant Auto Test
When the system is first energized, the CEPS-36W will self-test if the load and battery are connected correctly
and the battery is charging normally. If an abnormal condition is detected, the LED test switch will flash or flicker.
2) Pre-programmed scheduled Auto Test
- First monthly test will initiate several days after first energizing the CEPS-36W, from then it will conduct a test
every 30 days.
- First annual test will occur 52 weeks after first energizing the CEPS-36W, and every 52 weeks thereafter.
MANUAL TEST
- Press LTS one time, then go into emergency mode.
- Press LTS 2 times continuously within 5 seconds, then go into monthly test. After finish, the next monthly test will
count from this date.
- Press LTS 3 times continuously within 5 seconds, then go into annual test, after finish, the next annual test will
count from this date.
- During the manual test, press LTS above 3 seconds, then the manual test can be terminated (The
preprogrammed scheduled Auto Test time will not change).
LED TEST SWITCH (LTS) INDICATION
- LTS on: Normal
- LTS off: Power failure
- LTS strobe(gradual change): In testing
- LTS fast flashing: Abnormal
- LTS slow flashing: Battery charging

4
The CEPS-36W requires an unswitched AC power supply (input) 120-277VAC 50/60Hz.
CAUTION: DO NOT MATE UNIT CONNECTOR UNTIL INSTALLATION IS COMPLETE AND
AC POWER IS SUPPLIED.
WIRING DIAGRAM FOR NON-DIMMABLE EMERGENCY LIGHTING SYSTEM
TOTAL POWER = 36W ( )10°C≤Ta≤55°C
27W ( )0°C≤Ta<10°C
WHITE/RED
BLACK
YELLOW/GREEN
WHITE/BLACK
ANY QUANTITY
ORANGE (OUTHOT)
NEUTRAL
GROUND
SWITCH
HOT
LED Test Switch
RED (+)
WHITE (-)
RED (+)
WHITE (-)
120-277 VAC
120-277 VAC
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
DIM IN BLUE/WHITE (+)
DIM IN BLUE/RED (-)
0-10V
DIMMER
GRAY (OUT NEUTRAL)
①
①
②
②
③
④
⑤
⑤
⑥
VIOLET
VIOLET UNIT CONNECTOR
WIRING DIAGRAM FOR 1-10V DIMMABLE EMERGENCY LIGHTING SYSTEM
CEPS-36W
TOTAL DIMMABLE POWER UP TO 250W ( )10°C≤Ta≤55°C
WHITE/RED
BLACK
YELLOW/GREEN
WHITE/BLACK
ANY QUANTITY
DIM OUT BLUE (+)
DIM OUT BROWN (-)
ORANGE (OUTHOT)
NEUTRAL
GROUND
SWITCH
HOT
LED Test Switch
120-277 VAC
120-277 VAC
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
FOR EMERGENCY
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
LED
FLUORESCENT
INCANDESCENT
LUMINAIRE
0-10V
DIMMER
GRAY (OUT NEUTRAL)
RED (+)
WHITE (-)
RED (+)
WHITE (-)
DIM IN BLUE/WHITE (+)
DIM IN BLUE/RED (-)
①
②
①
②
④
⑤
⑥
⑦
③
③
⑥
VIOLET UNIT CONNECTOR
VIOLET
* The max. linkable luminaire quantity for emergency
will be different due to different electrical appliances,
which needs to be verified by end users.
CEPS-36W
NOTE: DO NOT ASSUME WHAT THE COLORS MEAN. FOLLOW WIRING DIAGRAM!!!
Popular Work Light manuals by other brands

Cooper Lighting
Cooper Lighting PQS45 instruction manual

GlacialTech
GlacialTech GL-FL55 Series user manual

Jefferson Professional Tools & Equipment
Jefferson Professional Tools & Equipment JEFWLT20WTEL-110 user guide

RUTEC
RUTEC VARDAFLEX 3inONE-30 manual

Night Stick
Night Stick NSR-2492 instruction manual

BAHAG
BAHAG 25385311 quick start guide