• 6 • • 7 •
USER MAINTENANCE
• Unplug and empty unit after each use.
• Do not store water or cleaning solutions in cleaning tank for any long
periods of time.
• Keep unit in cool, dry, ventilated location.
OPERATING INSTRUCTIONS
For step by step instructions please see our instructional videos on the
Lyman Products website at : www.lymanproducts.com
1. Open the lid and remove basket. Place items into basket, then put bas-
ket into the cleaning tank. Add water to a level between MIN and MAX
to cover the items being cleaned.
If the unit is turned on without water, ultrasonic energy will not be
absorbed. This model is high-powered. If turned on for more than 15
seconds without water, it may damage or severely reduce the life of
the unit.
2. Connect the power cord to an outlet and turn the switch on. LED dis-
play shows 05:00. This is the default setting and most common timer
setting and working state. If the timer needs to be adjusted, press
TIME button and button. The timer can be set between 1 and 30
minutes. Common cleaning times are 5, 10 or 15 minutes.
Prolonged cleaning time may result in:
a. Loosening of screws (if used).
b. Increasing pre-existing cracks.
c. Peeling of coating which was already separated.
3. Press On/Off button to start cleaning. During cleaning, 2 sets of blue
LED lights at the two sides of the unit illuminate, and a buzzing sound
can be heard from the cleaning tank, indicating that cleaning is under-
way. Closing the lid will reduce the noise level. The digital timer will
count down to show the remaining cleaning time. When it displays
00:00, the cleaning is done.
To stop cleaning at any time, press On/Off button. The unit is designed
with overheating protection to avoid extended and continuous operation
for too long. When the red light is on, the unit will not turn on even by
force. The unit will idle for about 20 minutes and can be restarted after
the green light comes on.
a. When the heater is needed, press TEMP button to select one of the 5
preset temperatures. Press TC button, flashes, indicating the heater
is turned on. LED Actual displays actual water temperature. When the
water reaches the set temperature, dims, indicating the heater is
turned off.
To ensure safety, the unit is designed with dual protection. The heater will
be turned off automatically if it has been running for 50 minutes.
b. To speed up the mixing and to use less solution, use De-gas function.
Press TIME button to set the timer for 10 minutes, then press FUNC-
TION button, illuminates. Press On/Off to start de-gassing. It
changes over to normal cleaning after 2 minutes.
c. When debris “smoke” is no longer visible, cleaning is done. If additional
cleaning is needed, reset the timer and repeat the previous steps.
4. When cleaning is completed, unplug the power cord, open the lid and
remove the basket. Connect the supplied drainage hose to the drain
nozzle by pushing straight on. Open the drainage valve to drain the
dirty water. Clean and wipe the tank dry. Close the drainage valve.
Remove drainage hose and rinse with clean water.
CLEANING SOLUTIONS
It is important to use the proper cleaning solutions for the material being
cleaned. Lyman offers several different ultra-sonic cleaning solutions for
your specific cleaning needs.Always follow the directions on the label of
the cleaning solution for best results.
TURBO®SONIC CONCENTRATED
CARTRIDGE CASE
CLEANING SOLUTION
Scientifically formulated to clean brass cases, will
remove tarnish, oxidation, and carbon buildup better
than competitive formulas. Designed for use in Lyman
Turbo Sonic cleaners and other ultrasonic cleaners.
Cleans brass inside and out, including primer pockets.
• Can be used to clean brass, copper, bronze and
stainless steel
• May be used for removal of light rust from steel
parts, but parts must be inhibited after cleaning
• Not recommended for use on aluminum or steel
(other than for removal of light rust)