manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Recording Equipment
  8. •
  9. M-system Mini-M M2SES User manual

M-system Mini-M M2SES User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5049 Rev.10 P. 1 / 3
INSTRUCTION MANUAL
Mini-M™
HIGH/LOW SELECTOR MODEL M2SES
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner (body + base socket).............................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■NONINCENDIVE APPROVAL OPTION
• This equipment is suitable for use in Class I, Div. 2,
Groups A, B, C and D or Non-Hazardous Locations only.
• WARNING! Before You Remove the Unit from Its Base
Socket or Mount It, Turn Off the Power Supply and Input
Signal for Safety.
• WARNING! – Explosion Hazard –
Substitution of Components May Impair Suitability for
Class I, Div. 2.
• WARNING! – Explosion Hazard –
Do Not Disconnect Equipment Unless Power Has Been
Switched Off or The Area is Known To Be Non-Hazardous.
• The equipment was evaluated for use in the ambient tem-
perature and relative humidity as mentioned in ‘ENVI-
RONMENT’ section.
• The input and output wiring must be in accordance with
Class I, Div. 2 wiring methods and in accordance with the
authority having jurisdiction for use in these hazardous
locations.
■CONFORMITY WITH EU DIRECTIVES, UK LEGISLATION OR UL
• This equipment is suitable for Pollution Degree 2 and In-
stallation Category II (transient voltage 2500V). Rein-
forced insulation (signal input or output to power input:
300V) and basic insulation (signal input to output: 300V)
are maintained. Prior to installation, check that the insu-
lation class of this unit satisfies the system requirements.
• Altitude up to 2000 meters.
• The equipment must be mounted inside a panel.
• The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE/UKCA/UL requirements. Failure to observe
these requirements may invalidate the CE/UKCA/UL
conformance.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may affect
the protection level of this unit when it is integrated in a
panel system. The user may have to review the
CE/UKCA
requirements in regard to the whole system and employ
additional protective measures to ensure the
CE/UKCA
conformity.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
100 – 240V and 85 – 264V AC rating: 85 – 264V
(90 – 264V for UL), 47 – 66 Hz, approx. 3 – 5VA
24V DC rating: 24V ±10%, approx. 3W
11 – 27V DC rating: 11 – 27V, approx. 3W
110V DC rating: 85 – 150V (110V ±10% for UL), approx. 3W
■GENERAL PRECAUTIONS
• Before you remove the unit from its base socket or mount
it, turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
• With voltage output, do not leave the output terminals
shortcircuited for a long time. The unit is designed to
endure it without breakdown, however, it may shorten ap-
propriate life duration.
COMPONENT IDENTIFICATION
Model
Body Base Socket
Connection
Diagram
Specifications
Fixing Screw
M2SES
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5049 Rev.10 P. 2 / 3
INSTALLATION
Loosen the fixing screw at the front of the unit in order to
separate the body from the base socket.
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
■DIN RAIL MOUNTING
Set the base socket so that
its DIN rail adaptor is at
the bottom. Position the
upper hook at the rear side
of base socket on the DIN
rail and push in the lower.
When removing the socket,
push down the DIN rail
adaptor utilizing a minus
screwdriver and pull.
■WALL MOUNTING
Refer to “EXTERNAL DIMENSIONS.”
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
5
9
21.5 (.85)
70.5 (2.78)
84 (3.31)10 (.39) 15 (.59)
6 (.23)
59 (2.32)
DIN RAIL
35mm wide
[4 (.16)]
8–M3
SCREW
72 (2.83)
23 (.91)
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
114 (4.49)
• When mounting, no extra space is needed between units.
4
8
12
14 13
1
4 (.16)
■CONNECTION DIAGRAM
1
4
+
–
INPUT 1
5
8
+
–
INPUT 2
+
–
OUTPUT
9
12
U(+)
V(–)
POWER
13
14
M2SES
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5049 Rev.10 P. 3 / 3
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm2(AWG 22 to 16)
Recommended manufacturer: Japan Solderless Terminal
MFG.Co.Ltd, Nichifu Co.,ltd
6 (.24) max
3.3 (.13) max
mm (inch)
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
13 – 14 with a multimeter.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Recording Equipment manuals

M-system R3-NM1 User manual

M-system

M-system R3-NM1 User manual

M-system M8BS2-162 User manual

M-system

M-system M8BS2-162 User manual

M-system Mini-M M2SES2 User manual

M-system

M-system Mini-M M2SES2 User manual

M-system R3 Series User manual

M-system

M-system R3 Series User manual

M-system M8BS2-164 User manual

M-system

M-system M8BS2-164 User manual

M-system M8BS2-161 User manual

M-system

M-system M8BS2-161 User manual

M-system M8BS2-042 User manual

M-system

M-system M8BS2-042 User manual

M-system EtherCAT R3-NECT1 User manual

M-system

M-system EtherCAT R3-NECT1 User manual

M-system R3-GE1 User manual

M-system

M-system R3-GE1 User manual

M-system 75ET User manual

M-system

M-system 75ET User manual

M-system R3-GM1 User manual

M-system

M-system R3-GM1 User manual

Popular Recording Equipment manuals by other brands

RTS OMNEO OEI-2 user manual

RTS

RTS OMNEO OEI-2 user manual

Marmitek activehome user manual

Marmitek

Marmitek activehome user manual

ArchWork ARCTAB user manual

ArchWork

ArchWork ARCTAB user manual

Tascam SS-R1 Specifications

Tascam

Tascam SS-R1 Specifications

Meyer Sound Galileo GALAXY 408 user guide

Meyer Sound

Meyer Sound Galileo GALAXY 408 user guide

Roland DEP-3 owner's manual

Roland

Roland DEP-3 owner's manual

Nagra PORTABLE ANALOGUE AUDIO TAPE RECORDER instruction manual

Nagra

Nagra PORTABLE ANALOGUE AUDIO TAPE RECORDER instruction manual

ICON Qcon ProX quick start guide

ICON

ICON Qcon ProX quick start guide

AMC IT-GSM quick start guide

AMC

AMC IT-GSM quick start guide

Audio Hungary qualiton MC user manual

Audio Hungary

Audio Hungary qualiton MC user manual

GRASS VALLEY T2 user manual

GRASS VALLEY

GRASS VALLEY T2 user manual

Roland U-220 quick start guide

Roland

Roland U-220 quick start guide

Hach SD900 user manual

Hach

Hach SD900 user manual

Yamaha FS1R Data list

Yamaha

Yamaha FS1R Data list

Zaxcom Deva 5.8 owner's manual

Zaxcom

Zaxcom Deva 5.8 owner's manual

PCCM MA-BOX2 manual

PCCM

PCCM MA-BOX2 manual

Studer PR99 MKIII Service manual

Studer

Studer PR99 MKIII Service manual

Liam & Daan STUDIO user guide

Liam & Daan

Liam & Daan STUDIO user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.