1. Connect AC220V power cable to the MCB.
2. Connect dry contact signal from card reader to terminal “Enter“, “GND“ and “Exit“ on the main board.
3. Connect driver and synchronize cables between master and slave as below:
Menu Setting - Enter setting mode by press and hold the “Enter“ button for 3s.
Display pass through count. (both way)
Set gate mode of enter and exit:
1. NC both Rej 2. NC both Free 3. NC both card (default) 4. NC card Free
5. NC card Rej 6. NC Free card 7. NC Free Rej 8. NC Rej Free
9. NC Rej card 10. NO both Free 11. NO both card 12. NO card Free
13. NO Free card
Set maximum waiting time 10-255, unit 0.1s (default is 5 seconds)
Set scan card with memory mode
0. Both disable (default), 1. Entry allow, 2. Exit allow, 3. Both allow
Set to allow card scanning when user standing in the lane. 1. Not allow (default), 2. Allow
Set door open delay time 0-255, unit 0.1s (default is 0)
Set door close delay time after user has walked through the lane, unit 0.1s (default is 0)
Rebound time = Time of door rebound when it is blocked during closing (30-250),
(default 100) [higher value, slower movement]
Action time = Time of door open/close. (30-250), (default 100) [higher value, slower movement]
Set end position IR sensor function (Do not modify) 1. Exit (default), 2. Safety
Set intrude alarm mode. 1. No alarm, 2. Alarm, 3. Alarm and close (default)
Set reverse alarm mode. 1. No alarm, 2. Alarm, 3. Alarm and close (default)
Set Tail-Gating alarm mode. 1. No alarm, 2. Alarm, 3. Alarm and close (default)
Advance parameter setting (Only for professional engineer level)
Set menu display language 1. English (default) 2. Chinese
Display Controller Device Type
Display hardware and firmware version
Multiple lanes connection