MAGICFX® SWIRLFAN II —User and Installation Manual 9
Menu function Explanation
Lock/Unlock
Controller
Holding the Lock button for more than 5 seconds will “lock” the
display functions. Meaning buttons will not respond. This to avoid
accidental change of parameters via display.To unlock, hold the
Unlock button for more than 5 seconds.
Reset Errors
In case there is a locking error present, this button will reset the
appliance. If the fault does not persist, the locking error will not
reappear.
DMX Start
Address (1-512) Setting the DMX start address.
DMX Safety
Address (1-512) Setting the DMX safety address.
DMX Footprint
This parameter indicates the DMX footprint, in other words the
amount of sequential channels used by the appliance. This does
not include the safety channel.
Display Dimmer
(On/O)
Turn display dimmer on or o. If turned on, the display is dimmed
automatically 30 seconds aer the last button push.
Factory
Defaults (Yes/
No)
Restores the appliance factory default settings.
Type (Alarm/
Error)
Toggle between the occured locking error (Alarm) list, and
blocking error (Error) list. Locking errors need intervention by user,
although they are “auto-reset” 3 times before the appliance
remains in error until reset by user. Blocking errors clear when the
triggering fault disappears. 16 locked, and 16 blocked errors are
logged. Top of the list shows the last occurring error.
Serial Number
(DDDDD) Appliance serial number as also printed on the appliance label.
Unique ID
(HHHHHHHHHHHH)
UID number as the appliance appears in the RDM device list aer
running discovery.
Soware
Version Installed soware version.
Soware CRC CRC of the functional soware.
Bootloader
CRC CRC of the bootloader soware.
Build Date Release date of functional soware.
Up-Time
(DDDD:HH:MM:SS)
Time counter which indicates how long the appliance has been
powered in total.
Eect-Time
(DDDD:HH:MM:SS)
Time counter which indicates how long the eect has been activated
in total.