A clearance hole for the anti-rotational screw must be drilled into the door frame before mounting the switch module; its position is
given on the templates. For anti-tamper purposes, the switch module has two sites for an anti-rotational threaded stud; only one
site will be used depending on which installation plan is chosen. Thread the screw into hole until about 1/4" of the screw remains
outside the module.
(continued) ingress door instructions: (continued) egress door instructions:
SITE OF ANTI-
ROTATIONAL SCREW FOR
OUTSWINGING DOOR
INSTALLATIONS ONLY
SITE OF ANTI-
ROTATIONAL SCREW
FOR INSWINGING DOOR
INSTALLATIONS ONLY
REVERSE SIDE OF THE SWITCH MODULE
DOOR
SWING
^SWITCH MODULE PERIMETER ^
MAGNET MODULE
SWITCH MODULE FACE MOUNT
DOOR
SWING
Mark & pilot-drill all hole locations. The single clearance hole
for the anti-rotational screw must now be drilled to 3/16" or
7/32" diameter. Drill the 3 mounting hole locations for the #10
screw (#21 bit). Drill the Removal-Tamper screw location
for the #6 screw (#35 bit). Hold the switch module in position:
Drive each screw in until seated, securing the device.
CAUTION: Magnasphere's magnet module and anti-
removal magnet are extremely powerful: Take precautions
to avoid the magnetic attraction between the magnet and
ferrous metals (or other magnets). Align the magnet
module directly below the switch module. Determine whether
spacers are needed to achieve mounted alignment of the
modules. Hold the magnet module and any necessary spacers
in position. Drill the 4 hole locations for #10 screws (#21 bit).
Drive each screw in location until each has seated, securing
the device.
Insert the Removal-Tamper magnet and then the Removal-
Tamper plug into the 3/8" hole at the face of the switch module.
Check the gap between modules. The mechanical installation
of the set is complete.
#6 screw
MAGNASPHERE CORP N22 W22931 Nancys Ct #3 Waukesha, WI 53186 tel 262.347.0711 fax 262.347.0710 www.magnasphere.com
Mark & pilot-drill all hole locations. The single clearance hole
for the anti-rotational screw must now be drilled to 3/16" or
7/32" diameter. Drill the 2 mounting hole locations for the #6
screw (#35 bit). Hold the switch module in position: Drive each
screw in until seated, securing the device.
CAUTION: Magnasphere's magnet module and anti-
removal magnet are extremely powerful: Take precautions
to avoid the magnetic attraction between the magnet and
ferrous metals (or other magnets). Align the magnet
module directly below the switch module. Determine whether
spacers are needed to achieve mounted alignment of the
modules. Hold the magnet module and any necessary spacers
in position. Drill the 4 hole locations for #10 screws (#21 bit).
Drive each screw in location until each has seated, securing
the device.
Insert the Removal-Tamper magnet and then the Removal-
Tamper plug into the 3/8" hole at the face of the switch module.
Check the gap between modules. The mechanical installation
of the set is complete.
MAY2019 L2X-0XX-FIRE INST REV0
Patents #6506987, #6803845, #6603378 & #8228191,
#8314698, 8648720, and Patents Pending
Additional mounting hardware, resistor configurations, cable lengths,
and other variants are available.
**Recommended placement to meet door opening and alarm requirements of UL634 Level 2. This guide is one means to meet this
standard. Installations which fulfill its requirements are not restricted to the specific recommendations in this instruction set.