Magswitch Pro Vertical Featherboard User manual

MAGSWITCH Pro Vertical Featherboard
P/N: 81101302
+ 1(303) 468.0622
magswitch.com
1101444 r01 For more information, contact our Application Engineers at +1.303.486.0622 or via magswitch.com Page 1
Summary
The Pro Vertical Featherboard is a table saw safety attachment which
pushes the workpiece down against the table during feeding to prevent
ride-up and kickback. Attach it to steel table saw fences between the
low-friction guide faces and adjust the feathers vertically to compress the
feathers against the workpiece. This is especially useful for thin material
hold-down and ensuring consistent depth-of-cut when cutting grooves.
Features
•Compressible gaskets provide excellent grip when magnets are
engaged.
•Anchors to table saw tables or fences to provide downward pressure
on work pieces
•Reversible for functionality on either side of the work piece (or fence)
•Broadly compatible with different fence sizes
•Multiple tools interlock together if downward force is needed at
multiple points.
Specifications
Nominal Maximum Breakaway Force 1
150 lbs
68 kg
Nominal Maximum Shear 1
40 lbs
18 kg
Net Weight
1.4 lbs
.63 kg
Footprint
(narrow dimension adjustable)
3.13" long x
1.95-2.72" wide
79.5mm long x
49.5-69mm wide
Vertical Adjustment Range
(relative to bottom surface)
+1.45"
-2.87"
+37mm
-73mm
1Determined in laboratory environment on 2” thick SAE1018 Steel with surface roughness 63 micro inches with optimized
pole shoes. Many factors contribute to the actual breakaway force and safe working load in each application. Consult a
Magswitch Applications Engineer and test the Magswitch in each application before deployment.
Pro Vertical Featherboard | P/N: 81101302
WARNING!
Do Not Operate Unless In Contact With Ferrous Target

MAGSWITCH Pro Vertical Featherboard
P/N: 81101302
+ 1(303) 468.0622
magswitch.com
1101444 r01 For more information, contact our Application Engineers at +1.303.486.0622 or via magswitch.com Page 2
Safety
•Items or body parts between the gripping surface of the magnet and ferromagnetic material are at risk of crushing and
impact forces.
•Never exceed the maximum rated load of Magswitch tools. This may result in an unsafe or dangerous condition.
•DO NOT attempt to alter the device in any way. This will void the warranty and may result in an unsafe or dangerous
condition.
•DO NOT attempt to disassemble the Magswitch magnet; there are no user serviceable parts inside.
•All Magswitch products are designed for normal worksite/jobsite conditions. Do not use underwater or in a hazardous
environment unless specifically designed for that purpose.
•DO NOT use a Magswitch product if it is damaged or not working properly. Severe injury can occur if this device is not used
properly and safely.
•Ensure Magswitch MagJigs are stored in the OFF position when not in contact with ferromagnetic materials.
•DO NOT turn the magnet ON unless it is in contact with ferromagnetic metal. Actuation off-target will generate a strong,
static, projected magnetic field which can accelerate, draw-in, and trap ferromagnetic material and damage magnetic
storage media.
•DO NOT expose standard Magswitch tools to temperatures above 176°Fahrenheit (80°Celsius). High temperatures will
permanently degrade the magnet’s effectiveness and may result in an unsafe condition.
•Always keep the bottom of the magnet clean and free of debris and rust. If needed, wipe with WD40 or light oil. The bottom
surface of the magnet must be flat, smooth, and in contact with steel to hold properly.
•Thicker steels will be held more strongly than thinner sheet. Steels with high alloy and carbon content will not be held as
strongly.
Warranty
Magswitch Limited Warranty
Magswitch products are covered by a one year limited warranty on material and workmanship. Warranty is non-transferable. Magswitch
reserves the right to inspect all product claims under warranty. Any alteration of the device voids this warranty. User assumes all risk for the
proper use of this device and for ensuring product suitability for intended application. This warranty shall not cover any incidental or
consequential damages due to the improper use or failure of this device. All Magswitch products are covered under International and U.S.
Patents 6,707,360 & 7,012,495. Add’l patents pending.
All Magswitch products are covered under International Patents. Australian Patents: 753496, 2006294433, Canadian Patents: 2,392,772, 2,458,251, Chinese Patent:
254155, European Patent: 1243006, Indian Patent: 219575, Korean(South) Patent: 10-0728448, Mexican Patent: 236,352, New Zealand Patent: 518865, Singapore
Patents: 88931; 103413, South Africa Patents: 2002/3752; 2004/1785, US Patents: 6,707,360; 7,012,495. Additional Patents and Patent Applications Pending in Hong
Kong, South Korea, China, Spain, Brazil, China, Japan. Trade Mark Registered in: European Union, Germany, Brazil, China
WARNING: This product can expose you to chemicals including nickel and tetrafluoroethylene, which are
known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov
WARNING: This product can expose you to chemicals including toluene, which are known to the State of
California to cause birth defects or other reproductive harm. For more information, go to
www.P65Warnings.ca.gov
WARNING: Drilling, sawing, sanding or machining wood products can expose you to wood dust, a
substance known to the State of California to cause cancer. Avoid inhaling wood dust or use a dust mask or
other safeguards for personal protection. For more information go to www.P65Warnings.ca.gov/wood.

MAGSWITCH Pro Vertical Featherboard
P/N: 81101302
+ 1(303) 468.0622
magswitch.com
1101444 r01 For more information, contact our Application Engineers at +1.303.486.0622 or via magswitch.com Page 3
Product Dimensions

MAGSWITCH Pro Vertical Featherboard
P/N: 81101302
+ 1(303) 468.0622
magswitch.com
1101444 r01 For more information, contact our Application Engineers at +1.303.486.0622 or via magswitch.com Page 4
Getting Started
1. Position Vertical Featherboard on fence preceding table saw
blade. One side of the base should contact the back side of the
fence wear surface.
2. Thread/unthread the screws in the base of the vertical
featherboard so they contact back side of the opposite fence
wear surface.
WARNING: The base of the featherboard should not be free
to twist when inserted in the gap between fence surfaces.
3. With the featherboard in position, rotate the handle
of the magnet clockwise 90° until the latch “clicks”
into place.
4. Loosen the black knob by rotating it
counterclockwise.
5. Lower the sliding feathers down to the table of the saw. The feathers
should compress at least ¼” or 6mm when the part passes underneath.
Avoid compressing the feathers more than ½” or 12mm or the feathers
may be damaged.
6. Tighten the black knob by rotating it clockwise to hold the sliding feathers
in place relative to the fence.
7. To remove the featherboard from the fence, press the latch on the rotating
handle and rotate the handle counterclockwise until the magnet is
disengaged. DO NOT tamper with the latch; it is a safety feature intended to keep the magnet engaged in the
event of kickback.
2
1
3
4
5

MAGSWITCH Pro Vertical Featherboard
P/N: 81101302
+ 1(303) 468.0622
magswitch.com
1101444 r01 For more information, contact our Application Engineers at +1.303.486.0622 or via magswitch.com Page 5
EU Declaration of Conformity
We, Magswitch Technology
Magswitch Technology World Wide Pty. Ltd.
Registered Office: C/- Shop 2B, 14 Short Street, Port Macquarie NSW 2444 Australia
Declare with sole responsibility that the machinery
Pro Vertical Featherboard, Pro Universal Featherboard, or other tool designations containing the “pro
featherboard” description and any accessories for these designations covered by these directives
Fulfils the relevant provisions of the following Union harmonisation legislation/directives:
•2006/42/EC Machinery Directive
•2011/65/EU Restriction of Hazardous Substances Directive (RoHS 2)
•2015/863 Restriction of Hazardous Substances Directive III (RoHS 3)
Conformity is shown by compliance with the applicable requirements of the following documents:
Ref: Title Date
ISO12100
Safety of machinery - General principles for design - Risk assessment
and risk reduction
2010
The Technical Construction File is maintained at:
Magswitch Technology, Inc.
1355 Horizon Ave, Lafayette CO 80026
ph. 303.468.0662 fax 303.951.9918
The authorised representative located within the Community is:
Cengiz Kizilkan
President Automation Sales
Magswitch Technology Europe
Marie-Curie-Str. 2
D-85055 Ingolstadt, Germany
Date of issue: 11/15/2019
Place of issue: Lafayette, Colorado, United States of America
David C. Long, Magswitch Engineering
This manual suits for next models
1
Table of contents
Other Magswitch Tools manuals