Additional notes:
1. On the transmitter, activate the Learn Mode:
468 931 003 260-1
.… Quick Start – Creating the radio link
Note: without correctly established radio link the receiver will work in Alarm mode, the room will be heated constantly to 30%.
Note for electric heating (the valve protection should be switched off
For INSTAT 868-r/rd (with display)
Details see manual item 6.8
With button Y, move cursor to k
Press and hold down button band additionally
press button Ybriefly.
The display reads xx:x(1) (x = any figure)
Change fourth digit to xx:x(0) (= valve protection off)
Press b
For INSTAT 868-r1 (without display)
Details see manual item 3.7
Open jumper BR1
4. Testing the radio link:
Adjust temperature to 30/40°, after ~30 sec the red lamp at the receiver will switch on
Adjust temperature to 5 °, after ~30 sec the red lamp at the receiver will switch off
For controllers without radio clock (INSTAT 868-r)
Clock and day of the week should also be adjusted, see manual item 2.5 (short description).
If necessary modify events and temperatures, see in manual table I, II and controller features table III.
For receivers INSTAT 868-a8U
If necessary: adjust clock see manual "Time and Date setting"
modify program see manual "Programming"
2. On receiver, activating the Learn Mode:
For INSTAT 868-a4 and -a6
Details see manual item 5
Note:
This receiver cannot be used
in combination with transmit-
ters 0525 98… or 517 1901…
(with 433 MHz)
For the channel to be learned, press the
related button.
E.g. for channel 1 press the button close to it briefly.
The red lamp will switch on and a tone can be heard
If the lamp at the receiver is switched off and the tone
stops, the radio link is established (after ~30 sec)
For INSTAT 868-a1 and -a1S
Details see manual items 5 or item 4 for the plug in receiver
Note:
This receiver cannot be used
in combination with transmitters
0525 98… or 517 1901… (with 433
MHz)
Press button zbriefly.
The red lamp will switch on and a tone can be heard
If the lamp at the receiver is switched off and the tone
stops, the radio link is established (after ~30 sec)
3. Cancelling Learn Mode on the Transmitter:
For INSTAT 868-r/rd (with display)
Press bbriefly
(Learn Mode is deactivated now)
Move cursor to kvia Y, for working with the
weekly program
For INSTAT 868-r1 (without display)
Press button RESET briefly (upper side)
Learn Mode is deactivated now)
For INSTAT 868-a8U
Details see manual item 5.1
Note
This receiver cannot be used in combination with transmitters 0525 98... or 517 1901 … (with 433 MHz)
Press auntil LErn is visible.
bThe already teached channels are visible on the lamps and in the display.
a, Zuntil the lamp for the requested room is blinking.
bto start learning mode. The channel LED and room arrow are blinking, digit in front of L
increments in sec interval. The actual received signal power will be displayed a sound can
be heard. If link is established, blinking and sound stopps (the room arrow remains, to
show the latest learned channel)
For INSTAT 868-r/rd (with display)
Details see manual item 6.17
Note:
This transmitter cannot be
used in combination with
receivers 052598… or
5071901/2… (with 433 MHz)
With button Y, move cursor to l
Press and hold down button band
additionally press button Ybriefly.
The display reads 0x:xx (x = any figure)
Change first digit to (1)x:xx
Press b
Symbol zcan be read bottom right
(Learn-Mode is active now)
For INSTAT+ 868-r
Details see manual item 2.1
In AUTO Mode press the <and >buttons
simultaneously for 3 seconds, USEr00 will be
displayed
press button >until option 9 is displayed.
press button +LErn will be displayed
press button >LErn is blinking, ON is visible;
Learn-Mode is now active
For INSTAT 868-r1 (without display)
Details see manual item 5
Note:
This transmitter
cannot be used in
combination with
receivers 052598…
or 5071901/2…
(with 433 MHz)
Press and hold down button ï(bottom)
and additionally
press button RESET (top) briefly.
The red lamp will switch on (Learn
Mode is active now)
For INSTAT+ 868-r
press button >to terminate Learn Mode
press buttons <and > simultaneously
for 3 seconds in order to activate AUTO
For INSTAT+ 868-r
Details see manual item 3.7
In AUTO Mode press the <and +
buttons simultaneously for 3 seconds,
INSk00 will be displayed
press button >until option 9 is displayed
press button +and select OFF (to
terminate use buttons <and +as
described above)