Maintronic Casambi CRD400 INS User manual

product number
10.273
product name
CRD400 INS
product designation
Casambi LED-/Retrofit Dimmer 380 VA
valid from version
H2 F1.5
Dokument Version: 20231107
Manufacturer's address and contact details
Adress MTC maintronic GmbH
Carl-Zeiss-Straße 10
D-97424 Schweinfurt/Germany
Contact details E-Mail
Web
Phone
www.maintronic.com
0049 9721 7766-0

Table of Contents
1. Notes to the instruction. CRD400 INS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Applicable documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.5 Used symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.6 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.7 Warranty and liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.8 Service and support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.9 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. Safety . CRD400 INS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 General safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.3 Not-intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3. Functions . CRD400 INS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1 Performance characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.2 Sicherheitsfunktionen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4. Technical data . CRD400 INS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5. Installation . CRD400 INS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.1 Considerations and planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.2 Mechanical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.3 Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6. Commissioning . CRD400 INS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.1 Operation with Casambi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.2 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.3Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7. Operation . CRD400 INS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7.1 Notes for operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7.2 Sensors and parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
7.3 Dimming characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7.4 Dimming Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7.5 LED flashing pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7.6 Operation with app . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7.7 Operation with Push-button input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
8. Troubleshooting . CRD400 INS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
8.1 Reset to factory default settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
8.2 Unpair devices from network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

CRD400 INS - 10.273 Manual english - www.maintronic.com / 3 38
1. Notes to the instruction. CRD400 INS
1.1 Applicable documents
This document contains all the necessary information for using this product.
Please refer to this document in partial instructions (such as installation instructions).
1.2 Usage
This manual describes everything necessary for the safe and efficient use of the device. The manual is an integral part of the product
and must be handed over to the end customer.
Please note that earlier versions of the product may differ in programming, operation and behavior and may not support all the
features described here.
Before installation, commissioning and operation, read this manual and pay attention to the warnings for safe handling, which are
marked as follows:
1.3 Safety information
DANGER
The signal word "DANGER" indicates an imminent danger. If not avoided, death or serious injury will result.
WARNING
The signal word "WARNING" indicates a possibly imminent danger. If it is not avoided, death or very serious injuries may
result.
CAUTION
The signal word "CAUTION" indicates a possibly imminent danger. If it is not avoided, slight or minor injuries may result.
CAUTION
The signal word "CAUTION" indicates a situation that can lead to material damage. Either to the product itself or to other
objects in the environment.
NOTE
The signal word "NOTE" indicates tips and recommendations to help you get the most out of the product.

CRD400 INS - 10.273 Manual english - www.maintronic.com / 4 38
1.5 Used symbols
Icon Description
The number indicates the number of
output channels of the device
The number indicates the number of
equipped push-button inputs
Max. output current per channel
Dimmed channel
LED dimmer
RGB+W color mixing
Dims RLC loads
R = resistive loads
L = inductive loads (conventional
transformers)
C = capacitive loads (electronic
transformers)
Zero-cross switch - Device powers up or
down by zero crossing of the sinewave
Weight in gramm
Temperature ambient (ta)
Icon Description
Astro function - control scenes through
sunrise and sunset
Group devices - create groups for joint
control
Logical inverting of channels. e.g. for a blind
up - down or CH1 and CH2
Timer function - execute time-controlled
automated functions
Scene control - save individual fixed images
as scenes or create a chaser with an
animation
Type of protection
Protection class II - protection throught
double insulation
Protection class III - protection throught
supplied from a seperated extra-low-voltage
Wireless protocol Casambi
DALI protocol interface
DALI protocol interface with device type 6

CRD400 INS - 10.273 Manual english - www.maintronic.com / 5 38
Temperature critical (tc)
Powersupply AC - the voltage details
either refer to a fixed voltage or a work ce
e.g. 100 to 240 V AC
Powersupply DC - the voltage details
either refer to a fixed voltage or a working
range e.g. +10 to 24 V DC
Powersupply DC - battery possible
Powersupply - powered from DALI
The number indicates how much space (in
TE) the device takes up on a DIN rail
Flush mouted housing - in installation
boxes or in devices of protection class II
Installation housing - installation in
ceiling, wall or luminaire
NOTE
The symbols explained here show the technical
data of the devices.
These symbols can be found in the technical
documentation of the respective device.
DMX protocol interface
DMX protocol interface with RDM
RS485 interface
Push-button input on mains voltage 230V AC
Push-button input
Wireless push-button input
Wireless controll
Wireless controll with gateway / repeater
function
Rollers and blinds function
changeover relay
Number indicates the amount of relays
Switch Relay (normally open contact)
Number indicates the amount of relays and
16A the switch current of the relay
Relay with high inrush current - current
peaks up to 165A for 20mS

CRD400 INS - 10.273 Manual english - www.maintronic.com / 6 38
1.6 Storage
Electrical devices are stored constantly at 10 to 25 degrees Celsius in dry storage rooms.
The devices must be protected from dust, moisture, splashing and dripping water.
1.7 Warranty and liability
Dieses Handbuch wurde mit größtmöglicher Sorgfalt erstellt, es sind dennoch Fehler und Irrtümer nicht vollständig auszuschließen. Die
Firma MTC maintronic GmbH übernimmt keinerlei Haftung für Personen- oder Sachschäden, die sich aus Fehlern oder Irrtümern in
dieser Bedienungsanleitung herleiten oder durch Nichtbeachtung von Sicherheitshinweisen.
Die Rechte von eventuell genannten fremde Firmennamen, Marken, Warenzeichen oder Logos liegen bei den jeweiligen Eigentümern.
1.8 Service and support
If you need special support beyond the information provided here, contact your distributor or the address in the Manufacturer Contact
section. .Herstellerkontakt
1.9 Disposal
Waste disposal
In accordance with European Directive 2002/96/EC (it`s) not longer usable electronic devices and defective or used
batteries (European Directive 2006/66EG) must collected separately and disposed by an environmentally sound
recycling.
This symbol indicates that electrical and electronic equipment must be disposed of separately from normal waste at the
end of its operational lifetime.
Should these product are no longer be useable, the user is required by law to dispose of old appliances separately from their
household waste e.g. at a local authority collection point or recycling center.

CRD400 INS - 10.273 Manual english - www.maintronic.com / 7 38
1.
2.
3.
4.
5.
2. Safety . CRD400 INS
2.1 General safety information
Qualified personnel
DANGER
The unit must only be installed and serviced by a proven electrican specialist, in accordance of all relevant regulations,
safety and accident prevention directives of the country.
Be sure that the existing mains voltage corresponds with the specified operating voltage before operating the device.
Risk of electric shock. Do not operate the device without a cover. Even when switched off, voltage may be present at the
outputs. When working on the device or connected loads, always disconnect the upstream fuse from the power supply.
Apply the "Five Safety Rules" (DIN VDE 0105, EN 50110):
Disconnect
Secure against being switched on again
Determine absence of voltage
Ground and short circuit
Cover or isolate nearby live parts
Only install the device in places with a good ventilation and without humidity or high temperatures. Do not expose the unit
to rain or snow. Do not operate the unit near heat sources, e.g. radiators.
If any of the following occurs, do not operate the device without first checking it:
if objects have fallen or liquid has been spilled into the unit.
if the device has been exposed to rain.
if the device does not operate normally or with altered characteristics.if the device has been dropped or has a broken
housing.
For cleaning only use a dry, soft cloth, by no means liquids.
Working on electrical installations
WARNING
Dangerous voltages in live installations, cables, plugs ...
Device-specific notes
WARNING
There is a risk of dangerous voltages being applied to the device (DALI, not SELV). If a person touches live parts, an electric
shock can cause serious injury or even death.
WARNING
For your own safety, read all instructions and information in this manual carefully before initial operation. Keep this
manual for future reference.
The instructions are an integral part of the product and must be handed to the end customer.
All information and instructions in this manual must be observed completely and in detail. The manufactuer is not
responsible for any direct or consequential damage that results from disregarding any information in this manual.

CRD400 INS - 10.273 Manual english - www.maintronic.com / 8 38
Waste disposal
In accordance with European Directive 2002/96/EC (it`s) not longer usable electronic devices and defective or used
batteries (European Directive 2006/66EG) must collected separately and disposed by an environmentally sound
recycling.
This symbol indicates that electrical and electronic equipment must be disposed of separately from normal waste at the
end of its operational lifetime.
Should these product are no longer be useable, the user is required by law to dispose of old appliances separately from their
household waste e. g. at a local authority collection point or recycling center.
CE-marking
The devices comply with the EU directives applicable at the time they are placed on the market.

CRD400 INS - 10.273 Manual english - www.maintronic.com / 9 38
2.2 Intended use
The device is a digital phase dimmer with automatic load detection in an INS installation housing.leading/trailing edge
The dimmer supports control via and via Casambi.button input (PushButton Input)
Module
Version
Installation
location
Description
INS Installation for installation in ceilings, walls or other cavities (pay attention to fire protection)
Das Gerät ist für Folgendes bestimmt:
dem Betrieb gemäß den aufgeführten technischen Daten
die Installation in trockenen Innenräumen
die Nutzung mit den am Gerät vorhandenen Anschlussmöglichkeiten
HINWEIS
Zur bestimmungsgemäßen Verwendung gehört auch die Einhaltung aller Angaben dieser Nutzerinformation.
HINWEIS
Bitte beachten Sie, dass sich vorangegangene Versionen des Produktes in Programmierung, Bedienung und Verhalten
unterscheiden können oder nicht alle hier beschriebenen Funktionen unterstützt werden!
1. Vergleichen Sie die Angabe der unterstützen Geräteversion dieses Handbuches (dieser Dokumentation) mit der Angabe
der Version auf dem Geräteaufkleber. Die Angabe zur Version findet sich auf dem Geräteaufkleber rechts unten:
2. Stimmt die Version Ihres Gerätes nicht mit der im Handbuch unterstützen Version überein, beschaffen Sie sich das
zugehörige Handbuch und verfahren nach der Anleitungen dort.

CRD400 INS - 10.273 Manual english - www.maintronic.com / 10 38
2.3 Not-intended use
Jede andere Verwendung gilt als bestimmungswidrig und kann zu Personen- und Sachschäden führen, insbesonders:
eigenmächtige bauliche Veränderungen
Reparaturen
Einsatz im Außenbereich
Einsatz in Nasszellen
haftet nicht für Schäden, die durch bestimmungswidrige Verwendung des Geräts entstehen. Das Risiko hierfür MTC maintronic GmbH
trägt allein der Benutzer/Betreiber.

CRD400 INS - 10.273 Manual english - www.maintronic.com / 11 38
3. Functions . CRD400 INS
3.1 Performance characteristics
The device can be controlled via the Casambi app, available for iOS and Android. Another optional operation ist given by the push
button input.
Casambi app automatically identifies the device and can be integrated into existing networks. All functions triggered by the buttons are
individually configurable.
As soon as the device is added to your network, it can be operated. Groups can be formed, scenes and timers can be created.
You can find all Casambi app related help on the official Casambi support sites at: .https://support.casambi.com
Product description
Digital leading- / trailing edge phase cutting dimmer with automatic load detection for a single dimmed phase. Equipped with an
additional push button input which extends the dimmer with a fast analogue control. Local control is so much easier.
For help with the configuration and operation of Casambi, please also refer to the official Casambi help at: https://support.casambi.
.com/
3.2 Features
mains dimmer rated power channels installation type
Control
1x PB Input
Temp enviroment
and electrical ...
Assembly end Shipping 1 unit
retail box

CRD400 INS - 10.273 Manual english - www.maintronic.com / 12 38
3.2 Sicherheitsfunktionen
Derating
The maximum dimmer load is possible up to an ambient temperature of 50 ° C. Between 50 and 70 ° C
(ta) (ta max allowed = t critical = )
tc
the maximum power decreases to 0 Watt.
The specified max. power rating applies to installation in a sufficiently ventilated location. In case of lower heat dissipation, e.g. in
cavity walls, flush-mounted/ junction boxes, as well as in case of mutual heating of several devices, the max. power rating is reduced
accordingly.
In case of overtemperature automaticly derating takes place, which means the power will reduced depending on the temperature.
Status-LED is indicating over temperature and the brightness of the lamps decreases.
Fig.: Derating curve of the CRD400 INS
Temperatures higher than 50°C are not specified in the approved ambient temperature.
However, the dimmer does not switch off hard and continues to adjust downwards even at higher temperatures.

CRD400 INS - 10.273 Manual english - www.maintronic.com / 13 38
4. Technical data . CRD400 INS
Specification CRD400 INS Item no. 10.273
Power supply 220 ... 240V AC 50/60Hz
Rated power 4 ... 380VA
Output power 0 ... +40°C Connected load 100%
+40 ... +50°C Note derating
Power consumption on idle / switching 0,6W / 1,8W at full load
Terminals, Wiring Screw terminal wiring single-wire: 0,2 … 4 mm²
fine-wire: 0,2 … 2,5 mm²
Striping length Striping length 6 mm (+/- 0,5 mm)
Tightening torque Tightening torque max. 0,2 Nm
Operation- and indication
units
Device Button, Status-LED
Protection circuits Short circuit with auto restart, over temperature (derating), over
current, over Voltage
Type of protection IP20, Class II
Temperature ambient (ta) 0 ... +50°C
Temperature critical (tc) +70°C
Humidity 5 - 80% non-condensing
Casambi App available for Android
and iOS
Bluetooth Low Energy (BLE)
Alternate control Casambi enabled push-
button input
230V AC
Approbation CE
Installation Installation housing
Licensed under DM/053379 of Tridonic
Mounting Installation in ceiling, wall or luminaire
Dimensions (height x width
x depth)
29,5 x 51x 101,5 mm
Weight 84g
Housing plastics, white
Customs tariff number 85365080
Co-applicable documents Installation instructions; manual

CRD400 INS - 10.273 Manual english - www.maintronic.com / 14 38
5. Installation . CRD400 INS
5.1 Considerations and planning
A Casambi network is a mesh network and every participant (dimmer, switches, etc.) extend the reach of the network.
Casambi is based on the energy-saving Bluetooth 4.0 standard. If a module is nearby, all luminaires within range of this module can be
controlled.
Bluetooth has a range of up to 20 m. Plan your network in such a way that the radio coverage of the modules is guaranteed with each
other and no dead spots arise.
If there are gaps in the network or modules are positioned at the limit of the radio coverage, strange errors can sometimes occur.
Before putting the device into operation, make sure that the correct power supply and power class is selected.
Dimmer for brightness control of illuminants such as incandescent lamps, high-voltage halogen lamps, dimmable LED lamps for 230 V.
1-channel universal dimming actuator
With a pre-fuse of max. 16A
Installation housing INS
Operate the device (Operation) only in dry indoor rooms (below 80 % humidity, non condensing)
68 mm pitch circle. (68 mm hole)

CRD400 INS - 10.273 Manual english - www.maintronic.com / 15 38
Power calculation depending of the used lighting source
Load type cutting method Percentual rated output power
Ohmic trailing edge 100 %
LED trailing edge approx. 80 %
copper transformer leading edge*approx. 20 %
* leading edge is (only) for copper transformersmandatory
Example:
A rule of thumb calculation for LEDs with internal power supply:
-Given is trailing edge as cutting method
- 20x LED 7.5 watts = 150 watts (nominal power of the LEDs)
- plus additional charge 20% (for capacitive parts of the LED load characteristic)
Result: 180 watts as total power is required.

CRD400 INS - 10.273 Manual english - www.maintronic.com / 16 38
5.2 Mechanical installation
Dimensions
Installation housings for dry interiors for installation or mounting in walls, ceilings or other cavities.
Installation
Due to the compact dimensions and the rounded shape, an easy installation is possible for all feed-through openings from 68 mm pitch
circle.
The integrated strain relief and terminal cover eliminates additional wiring and junction box.

CRD400 INS - 10.273 Manual english - www.maintronic.com / 17 38

CRD400 INS - 10.273 Manual english - www.maintronic.com / 18 38
5.3 Electrical installation
Connections
1 Output, dimmed phase 230V AC
2 N Neutral conductor
3 N Neutral conductor
4 L Input mains, phase 230V AC
5 N Input push button, neutral N
6 L Input push button, phase L - 230V AC
Connection diagram
Wiring
0,2...4mm² single wire
0,2...2,5mm² fine wire
0,5...2,5mm² fine wire with ferrule
6mm

CRD400 INS - 10.273 Manual english - www.maintronic.com / 19 38
Operating elements
Elements
1 Status-LED
2 Device-button

CRD400 INS - 10.273 Manual english - www.maintronic.com / 20 38
1.
2.
3.
4.
5.
6. Commissioning . CRD400 INS
6.1 Operation with Casambi
The device can be controlled via the Casambi app, available for iOS and Android. Another optional operation ist given by the push
button input.
Casambi app automatically identifies the device and can be integrated into existing networks. All functions triggered by the buttons are
individually configurable.
As soon as the device is added to your network, it can be operated. Groups can be formed, scenes and timers can be created.
You can find all Casambi app related help on the official Casambi support sites at: .https://support.casambi.com
6.2 Commissioning
To make sure that the functionality of the device is up to date, first of all you have to check
if a new firmware is available.
Update firmware
Open Casambi App
Go to nearby devices
Scroll down
Check for updates
If an update is available, please install
Other manuals for Casambi CRD400 INS
1
This manual suits for next models
1
Table of contents
Other Maintronic Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

TKH
TKH 797 Installation and maintenance instructions

Eaton
Eaton CEAG Exit Cube 33822 LED CGLine+ Mounting and operating instructions

LIGMAN
LIGMAN KWH 11 installation manual

ETC
ETC Desire D60 XTI user manual

Daniamant
Daniamant SL-450 Installation and maintenance instructions

luminii
luminii CLTC Series installation instructions