Makita EG301A User manual

3ZZ9990516
EG series
EG301A
EG381A, EG381AE
EG511A, EG511AE
EG711A, EG711AE
EG781A, EG781AE
EGséries
EG301A
EG381A, EG381AE
EG511A, EG511AE
EG711A, EG711AE
EG781A, EG781AE

AIR INDEX
Descriptive Term Applicable to Emissions Durability Period
Moderate - 50 hours (engine from 0 to 80 cc)
125 hours (engine greater than 80 cc)
Intermediate - 125 hours (engine from 0 to 80 cc)
250 hours (engine greater than 80 cc)
Extended - 300 hours (engine from 0 to 80 cc)
500 hours (engine greater than 80 cc)
1000 hours (225 cc and greater)
WARNING :
The engine exhaust from this product contains
chemicals known to the State of California to
cause cancer, birth defects or other reproductive
harm.
To show compliance with California emission regulations, a hangtag has been provided
displaying the Air Index level and durability period of this engine.
The Air Index level defines how clean an engine’s exhaust is over a period of time. A bar
graph scaled from “0” (most clean) to “10” (least clean) is used to show an engine’s Air Index
level. A lower Air Index level represents cleaner exhaust from an engine.
The period of time (in hours) that the Air Index level is measured is known as the durability
period. Depending on the size of the engine, a selection of time periods can be used to
measure the Air Index level (see below).
Notice : This hangtag must remain on this engine or piece of equipment, and only be
removed by the ultimate purchaser before operation.
Notice : FEDERAL EMISSION COMPONENT DEFECT WARRANTY and CALIFORNIA EMISSION CONTROL
WARRANTY are applicable to only those engines/ generators complied with EPA (Environmental
Protection Agency) and CARB (California Air Resources Board) emission regulations in the U.S.A.
Notice : To the engines/generators exported to and used in the countries other than the U.S.A., warranty service
shall be performed by the distributor in each country in
accordance with the standard engine/generator
warranty policy as applicable.
(California Proposition 65)
(California only)
EG781AEceGU683710.1.251:36PMページ001

EG781AEceGU683710.1.251:36PMページ002

ENGLISH
FOREWORD
Thank you for purchasing a Makita generator.
This manual covers operation and maintenance of the Makita generators.
All information in this publication is based on the latest production
information available at the time of approval for printing.
Pay special attention to statements preceded by the following words:
■The generator is designed to give safe and dependable service if
operated according to instructions.
■Do not operate the generator before you have read and
understood the instructions. Failure to do so could result in death,
personal injury or equipment damage.
WARNING
Indicates a strong possibility of severe personal injury, loss of life and
equipment damage if instructions are not followed.
[CAUTION]
Indicates a possibility of personal injury or equipment damage if instructions
are not followed.
NOTE:
Gives helpful information.
If a problem should arise, or if you have any questions about the generator,
consult an authorized dealer or service shop
WARNING
Indicates a possibility of death or serious injury if instructions are not
followed.
DANGER
EG781AEceGU683710.1.251:36PMページ01

CONTENTS
1. SAFETY PRECAUTIONS ・・・・・・・・・・・・・・・・ 1
2. SPECIFICATIONS ・・・・・・・・・・・・・・・・・・・ 3
3. COMPONENTS ・・・・・・・・・・・・・・・・・・・・ 4
4. PRE-OPERATION CHECKS・・・・・・・・・・・・・・・ 7
5. OPERATING PROCEDURES ・・・・・・・・・・・・・・11
6. WATTAGE INFORMATION ・・・・・・・・・・・・・・・21
7. SPARK ARRESTER ・・・・・・・・・・・・・・・・・・23
8. MAINTENANCE SCHEDULE ・・・・・・・・・・・・・・24
9. "HOW-TO" MAINTENANCE・・・・・・・・・・・・・・・26
10. PREPARATION FOR STORAGE ・・・・・・・・・・・・・30
11. TROUBLESHOOTING ・・・・・・・・・・・・・・・・・31
12. WIRING DIAGRAM ・・・・・・・・・・・・・・・・・・32
EG781AEceGU683710.1.251:36PMページ02

1. SAFETY PRECAUTIONS
−1−
ENGLISH
Please make sure you review each precaution carefully.
Do not operate the generator near gasoline or gaseous fuel because of the
potential danger of explosion or fire.
Do not fill the fuel tank with fuel while the engine is running. Do not smoke or
use open flame near the fuel tank. Be careful not to spill fuel during refueling.
If fuel is spilt, wipe it off and let dry before starting the engine.
WARNING
WARNING
Do not place in flammables near the generator.
Be careful not to place fuel, matches, gunpowder, oily cloths, straw, trash, or any other in flammables
near the generator.
WARNING
Do not enclose the generator nor cover it with a box.
The generator has a built-in forced air cooling system, and may become overheated if it is enclosed.
If generator has been covered to protect it from the weather during non use, be sure to remove it and
keep it well away from the area during generator use.
WARNING
1m
1m
Operate the generator on a level surface.
It is not necessary to prepare a special foundation for the generator.
However, the generator will vibrate on an irregular surface, so choose a level place without surface
irregularities.
If the generator is tilted or moved during operation, fuel may spill and / or the generator may tip over,
causing a hazardous situation.
Proper lubrication cannot be expected if the generator is operated on a steep incline or slope. In such
a case, piston seizure may occur even if the oil is above the upper level.
WARNING
Pay attention to the wiring or extension cords from the generator to the connected device.
If the wire is under the generator or in contact with a vibrating part, it may break and
possibly cause a fire, generator burnout, or electric shock hazard.
Replace damaged or worn cords immediately.
WARNING
Do not operate the generator inside a room, cave, tunnel, or other
insufficiently ventilated area.
Always operate it in a well-ventilated area, otherwise the engine may
become overheated, and the poisonous carbon monoxide gas, an
odorless, colorless, poison gas, contained in the exhaust gas will
endanger human lives.
Operate generator only outdoors and far from open windows, doors,
ventilation intakes and other openings.
Keep the generator at least 1 meter (3 feet) away , including overhead,
from any structure or building use.
EG781AEceGU683710.1.251:36PMページ1

−2−
Do not contact the generator to a commercial power line. Connection to a commercial
power line may short circuit the generator and ruin it or cause electric shock hazard.
Use the transfer switch for connecting to domestic circuit.
WARNING
Engine becomes extremely hot during and for some time after operation.
Keep combustible materials well away from generator area.
Be very careful not to touch any parts of the hot engine especially the muffler area
or serious burns may result.
WARNING
No smoking while handling the battery. The battery emits flammable hydrogen gas,
which can explode if exposed to electric arcing or open flame.
Keep the area well-ventilated and keep open flames/sparks away when handling the battery.
WARNING
Do not operate in rain, in wet or damp conditions, or with wet hands.
The operator may suffer severe electric shock if the generator is wet due to rain or snow.
WARNING
Keep children and all bystanders at a safe distance from work areas.
WARNING
If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it
with water.
WARNING
Be extremely careful that all necessary electrical grounding procedures are followed during each and
every use. Failure to do so can be fatal.
WARNING
It is absolutely essential that you know the safe and proper use of the power tool or appliance that
you intend to use. All operators must read, understand and follow the tool/appliance owners manual.
Tool and appliance applications and limitations must be understood. Follow all directions given on
labels and warnings. Keep all instruction manuals and literature in a safe place for future reference.
WARNING
Use only "LISTED" extension cords.
When a tool or appliance is used outdoors, use only extension cords marked "For Outdoor Use".
Extension cords, when not in use should be stored in a dry and well ventilated area.
WARNING
Always switch off generator's AC circuit breaker and disconnect tools or appliances when not in use,
before servicing, adjusting, or installing accessories and attachments.
WARNING
CAUTION
Make sure the engine is stopped before starting any maintenance, servicing or repair.
Make sure maintenance and repair of the generator set are performed by properly trained personnel only.
EG781AEceGU683710.1.251:36PMページ2

2. SPECIFICATIONS
−3−
ENGLISH
MODEL
Type
Starting system
L
mm
mm
mm
mL
L
kg
Model
Type
Voltage regulating system
VA (W)
Rated output
Rated current
AC Output
Rated voltage
Fuel tank capacity
Engine oil capacity
Spark plug
Dry weight
Specifications are subject to change without notice.
*1: ( ) shows the filled amount up to the "LEVEL" position.
*2: ( ) shows dimensions with Battery frame.
*3: ( ) shows weight with Electric starter.
Displacement
ROBIN, Air-cooled, 4-stroke, OHC, Gasoline Engine
211
Length
Width
Height
Recoil
starter Electric starter / Recoil
17.8
(21.5)*1
BR-6HS (NGK)
0.6
12.8
(16.6)*1
Fuel Automotive Unleaded Gasoline
Fuse-less circuit breaker
V
Rated current
12
A
Safety device type
8.3
DC Output
Rated power factor 1.0
AVR type
120/240-60120-60
EG381A
EG381AE
EG511A
EG511AE
EG711A
EG711AE
EG301A
EX30D EX35D
22.0
(27.5)*1
EX17D
287 404169
Brush, self-exciting, 2-poles, single phase
2900
V-Hz
Rated voltage-Frequency
Safety device type Fuse-less circuit breaker
2400 4200
EX21D
675
(925)*2
600 620
(870)*2
510420 450
570500 500
69
(79)*3
725
(975)*2
530
580
86
(96)*3
47 52
(58)*3
Direction of rotation Counter - clockwise
1.0 1.2
A24.2 / 12.120 35 / 17.5
5000
41.7 / 20.8
EG781A
EG781AE
EX40D
89
(99)*3
kg
Gross weight
Weight according to EPTA procedure 01/2003
83(86)*1
(93(96))*3
104(108)*1
(114(118))*3
57(60)*1 62(65)*1
(68(71))*3
107(111)*1
(117(121))*3
6000
50 / 25
Engine Generator
Dimension
EG781AEceGU698910.2.81:48PMページ3

3. COMPONENTS
−4−
Fuel tank
Fuel gauge
Engine switch
Choke lever
Oil drain plug
Oil gauge (oil filler)
Spark plug cap
Air cleaner
Exhaust outlet
Tank cap
Fuel strainer
(Fuel valve)
Muffler cover
Recoil starter
Recoil starter
handle
Control panel
EG301A, EG381A, EG381AE, EG511A, EG511AE
EG781AEceGU683710.1.251:36PMページ4

−5−
ENGLISH
Control panel
Fuel tank
Fuel gauge
Engine switch
Recoil starter
handle
Choke lever
Oil gauge (oil filler)
Spark plug cap
Air cleaner
Muffler
Tank cap
Recoil starter
Oil drain plug
EG711A, EG711AE, EG781A, EG781AE
EG781AEceGU683710.1.251:36PMページ5

−6−
ï
EG301A
EG511A, EG511AE
EG711A, EG711AE
EG781A, EG781AE
EG381A, EG381AE
Pilot lamp
AC receptacle 20A
Earth (ground)
terminal
AC circuit
breaker
AC circuit
breaker
DC
receptacle
DC circuit
breaker
DC circuit
breaker
AC receptacle 30A
AC receptacle 20A
Engine switch
[Electric starter model]
Engine switch
Pilot lamp
Earth (ground)
terminal
AC circuit
breaker
AC circuit
breaker
DC
receptacle
DC circuit
breaker
Engine switch
Key switch
AC receptacle 30A
Pilot lamp
Full power
switch
AC circuit
breaker
Full power
switch
AC receptacle 30A
Earth (ground) terminal
Idle Control
Switch
DC
receptacle
AC receptacle 20A
[Electric starter model]
Key switch
CONTROL PANEL
EG781AEceGU683710.1.251:36PMページ6

4. PRE-OPERATION CHECKS
−7−
ENGLISH
Upper level
Oil filler cap
(Oil gauge)
Lower level
CHECK ENGINE OIL
Before checking or refilling oil, be sure
generator is located on stable and level
surface with engine stopped.
■Remove oil filler cap and check the
engine oil level.
■If oil level is below the lower level line,
refill with suitable oil (see table) to
upper level line. Do not screw in the
oil filler cap when checking oil level.
■Change oil if contaminated.
(See "How-To" Maintenance.)
Recommended engine oil :
Use 4-stroke automotive detergent oil
of API service class SE or higher grade
(SG, SH or SJ is recommended).
SAE
10W-30 or 10W-40 is recommended
for general, all-temperature use. If
single viscosity oil is used, select the
appropriate viscosity for the average
temperature in your area.
Ambient
temperature
Single grade
Multigrade
5W
10W
20W
#20
#30
#40
10W
-
30
10W
-
40
EG301A . . . . . . . . . . . . . . . 0.6 (0.15)
EG381A,
EG381AE
. . . . . . 0.6 (0.15)
EG511A, EG511AE . . . . . . 1.0 (0.26)
EG711A, EG711AE . . . . . . 1.2 (0.32)
EG781A,
EG781AE
. . . . . . 1.2 (0.32)
Oil capacity (Upper level) :
L (U.S. gal)
EG781AEceGU683710.1.251:36PMページ7

−8−
■Check fuel level at fuel level gauge.
■If fuel level is low, refill with
unleaded automotive gasoline.
■Be sure to use the fuel filter screen
on the fuel filter neck.
LEVEL
Fuel filter screen
Fuel tank cap
FULL
EMPTY
EMPTY
FULL
EF
EG711A,
EG711AE
EG781A,
EG781AE
EG301A
EG381A,
EG381AE
EG511A, EG511AE
Do not refuel while smoking or near open flame or other such
potential fire hazards. Otherwise fire accident may occur.
CHECK ENGINE FUEL.
Make sure you review each warning in order to prevent fire hazard.
■Do not refill tank while engine is running or hot.
■Close fuel valve before refueling with fuel.
■Be careful not to admit dust, dirt, water or other foreign objects Into
fuel.
■Wipe off spilt fuel thoroughly before starting engine.
■Keep open flames away.
WARNING
WARNING
NOTE :
THIS ENGINE IS CERTIFIED TO OPERATE
ON AUTOMOTIVE UNLEADED GASOLINE.
Fuel Amount
up to "LEVEL" position : (L)
EG301A . . . . . . . . . . . . . . . . . . 12.8
EG381A,
EG381AE
. . . . . . . . . 12.8
EG511A, EG511AE . . . . . . . . . 17.8
EG711A, EG711AE . . . . . . . . . 22.0
EG781A,
EG781AE
. . . . . . . . . 22.0
EG781AEceGU683710.1.251:36PMページ8

−9−
ENGLISH
CHECKING COMPONENT PARTS
Check following items before starting engine:
■Fuel leakage from fuel hose, etc.
■Bolts and nuts for looseness.
■Components for damage or breakage.
■Generator not resting on or against any adjacent wiring.
CHECK GENERATOR SURROUNDINGS
Make sure you review each warning in order to prevent fire hazard.
■Keep area clear of in flammables or other hazardous materials.
■Keep generator at least 3 feet (1 meter) away from buildings or other
structures.
■Only operate generator in a dry, well ventilated area.
■Keep exhaust pipe clear of foreign objects.
■Keep generator away from open flame. No smoking!
■Keep generator on a stable and level surface.
■Do not block generator air vents with paper or other material.
WARNING
BATTERY INSTALLATION (Electric Starter Model)
Recommended Battery
Type ; Lead-acid battery
Capacity (Ah/5hr) ; 12V-21AH or more
Size ; Less than 185(L) x 125(W) x 160(H) mm
Battery Frame #2
Bolt
Nut
Nut
Bolt
Bolt
Protection Plate
Bolt
Nut
Setting Bolt
Battery Frame #1
Setting Plate
Bolt
Battery Plate
Starter Cable(RED)
Earth Cable(BLACK)
EG781AEceGU683710.1.251:36PMページ9

−10−
GROUNDING THE
GENERATOR
■To ground the generator to the earth,
connect the grounding lug of the
generator to the grounding spike
driven into the earth or to the
conductor which has been already
grounded to the earth.
■If such grounding conductor or
grounding electrode is unavailable,
connect the grounding lug of the
generator to the grounding terminal of
the using electric tool or appliance.
Grounding spike
Death, personal injury and/or property damage may occur unless
instructions are followed carefully.
■Use battery of recommended capacity.
■Turn the starter switch to the "STOP" position when mounting or
dismounting battery. When mounting battery, connect the positive (+)
cable first and then the negative (
-
) cable to the battery. Be careful not to
short battery cables. When dismounting battery, disconnect negative (
-
)
cable first.
RED CABLE : To positive (+) terminal
BLACK CABLE : To negative (
-
) terminal
■Should the connection be made in incorrect manner, the generator will
be broken.
■Tighten bolts and nuts on terminals securely so they will not be
loosened by vibration.
■Disconnect battery cables when charging battery.
WARNING
EG781AEceGU683710.1.251:36PMページ10

5. OPERATING PROCEDURES
−11−
ENGLISH
(a) Turn the Engine switch to the position
"ON".
(b) Turn the AC circuit breaker to the
position "OFF".
(c) Open the fuel valve.
(d) Set choke lever to close if the engine
is cold.
STARTING THE GENERATOR
Check the oil level before each operations as outlined by the article
"CHECK ENGINE OIL"
[CAUTION]
ON
OFF
OPEN
CLOSE
CLOSE
Choke lever
CLOSE
OPEN
ON
OFF
OFF
EG781AEceGU683710.1.251:36PMページ11

−12−
Pull briskly
(e) [Recoil starter model]
Pull the starter handle slowly until
passing the compression point
(resistance will be felt), then return
the handle to its original position
and pull briskly.
■If the engine fails to start after several
attempts, repeat above procedures
with choke lever returned to "OPEN"
position.
■Do not fully pull out the rope.
■After starting, allow the starter handle
to return to its original position while
still holding the handle.
(f) [Electric starter model]
Insert the key into the key switch and
turn it clockwise to the "RUN" position
to start the engine.
Then turn the key further to the
"START" position. The engine will be
started by starting motor.
RUN
STOP
STOP
RUN
START
START
■Do not run the starting motor over 5seconds continuously.
If the engine fails to start, return the key to the "RUN" position and wait
about 10 seconds then start again.
■Do not turn the key switch to "START" position when the engine is
running to prevent damage of starting motor.
■When starting the engine by recoil starter, set the key switch at the "ON"
position and pull the starter handle.
[CAUTION]
EG781AEceGU683710.1.251:36PMページ12

−13−
ENGLISH
(g) After the engine started, return the
choke lever gradually to "OPEN"
position.
Choke lever
CLOSE
OPEN
(h) Warm up the engine without a load for
a few minutes.
EG781AEceGU683710.1.251:36PMページ13

−14−
(a) Make sure the pilot lamp is turned on.
(b) Turn off the switch (es) of the electrical
appliance (s) before connecting to the
generator.
(c) Insert the plug (s) of the electrical
appliance(s) into the receptacle.
(1) AC APPLICATION
USING ELECTRIC POWER
■Make sure that the appliance is switched OFF before connecting it to
the generator.
■Do not move the generator while it is running.
■Be sure to ground the generator if the connected appliance is
grounded. Failure to ground unit may lead to electrical shock.
WARNING
■Check the amperage of the receptacles used referring to TABLE 1, and be
sure not to take a current exceeding the specified amperage.
■Be sure that the total wattage of all appliances dose not exceed the rated
output of the generator.
EG781AEceGU683710.1.251:36PMページ14

−15−
ENGLISH
TABLE 1
NOTE :
When the AC circuit breaker turns off during operation, the generator is over
loaded or the appliance is defective. Stop the generator immediately, check the
appliance and / or generator for overloading or detect and have repaired as
necessary by Makita factory or authorized service center.
■To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn
it clockwise to the lock position.
■Be sure to ground the generator if
the connected electrical device Is
grounded.
WARNING
TWIST
up to 30A
up to 20A NEMA
5-20R
NEMA
L14-30R
NEMA
5-20P
NEMA
L14-30P
GFCI (Ground Fault
Circuit Interrupter)
Receptacle, duplex
(REC1)
Locking Receptacle
(REC4)
Style Ampere Receptacle AC plug Description
up to 30A NEMA
L5-30R
NEMA
L5-30P
Locking Receptacle
(REC3)
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit
Interrupter). GFCI shuts off the output current from the duplex 120V
receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.
[CAUTION]
EG781AEceGU683710.1.251:36PMページ15
This manual suits for next models
8
Table of contents
Other Makita Portable Generator manuals

Makita
Makita G2800N User manual

Makita
Makita EX Series G4300L Quick start guide

Makita
Makita G1700I User manual

Makita
Makita G2800R User manual

Makita
Makita G1200R User manual

Makita
Makita G2800I User manual

Makita
Makita G1100 User manual

Makita
Makita ADP05 User manual

Makita
Makita EG2250A User manual

Makita
Makita G1700I Quick start guide