TECHNICAL SPECIFICATIONS
Detection area
Daylight sensor
0-10V
out
control
LED indication
Antenna module
Hold-time
Daylight threshold
Stand-by period
Stand-by dimming
level
Product type: Microwave Motion Sensor
Operating voltage: 220-240V~ 50/60Hz
HF system: 5.8GHz CW radar
Transmission power: <0.2mW
Rated load: 800W (capacitive load)
Detection angle: 30-150º
Power consumption: Approx 0.5W
Detection range: Max. 12 m in diameter, adjustable
Time setting: 5 s ~ 30 min.
Mounting: Indoors, ceiling or wall
Light control: 2~50 LUX, disable
Stand-by period: 0s, 10s ~ 1H, +∞
Stand-by dimming level: 10%~50%
Working temperature: -35~70ºC
Standby consumption: Psb<0.5W
The sensor works with a main voltage of 220-240V AC
50/60Hz.
The sensor has a 7-wire electrical interface:
Nx2 (neutral / 220-240V AC)
L (phase / 220-240V AC)
L’ (switched phase / output)
Push (push switch interface)
– (1-10V “–”) interface)
+ (1-10V “+”) interface)
INSTALLATION & WIRING
Försäkra dig om att strömmen är helt avstängd innan installa-
tion eller underhåll.
SE
Ensure that the electricity supply is switched off completely
before installation or servicing this product.
EN
Sensorn funkar med spänning 220-240V AC 50/60Hz.
Sensorn har sju plintar:
Nx2 (nolla / 220-240V AC)
L (fas / 220-240V AC)
L’ (tändtråd)
Push (push switch)
– (1-10V “–”)
+ (1-10V “+”)
The sensor is an active motion detector; it emits a high-frequency
electromagnetic wave 5.8GHz and receives its echo. The sensor
detects the change in echo from movement in its detection zone.
A microprocessor then triggers the switch light ON command.
Detection is possible through doors, glass panels and thin walls.
NOTE: the high-frequency output of this sensor is <0.2mW;
approximately just 2‰ of the transmission power of a mobile
telephone or the output of a microwave oven.
IMPORTANT
PLEASE READ THESE INSTRUCTION CAREFULLY PRIOR TO INSTALLATION AND RETAIN THIS LEAFLET IN A
KNOWN AND SAFE PLACE FOR FUTURE REFERENCE.
<0.2mW Approx. 100mW
Push

AF-JA/JZ-211103
Hold time:
This determines the time the fitting remains at 100% level on motion detection and is set
with DIP switches at the sensor itself, refer to figure.
The following settings are available:
I – 5s V – 10 minutes
II – 30s VI – 20 minutes
III – 1 minutes VII – 30 minutes
IV – 5 minutes
Detection Area:
This determines the effective range of the motion detector and is set by DIP switches at
the sensor itself, refer to figure. Note that reducing the sensitivity will also narrow the
detection range. The following settings are available:
I – Detection range 100%
II – Detection range 75%
III – Detection range 50%
IV – Detection range 10%
Daylight sensor:
This setting holds off the 100% light output should there be sufficient daylight and is set
using DIP switches at the sensor, refer to figure. The following settings are available:
I – Disable
II – 50Lux
III – 10Lux
IV – 2Lux
Stand-by period (corridor function):
This is the time period you would like to keep at the low light output level before it is com-
pletely switched off in the long absence of people.
I – 0s V – 10min
II – 10s VI – 30min
III – 1min VII – 1h
IV – 5min VIII – +∞
Stand-by dimming level:
This is the dimmed low light output level you would like to have after the hold-time in the
absence of people.
I – 10%
II – 20%
III – 30%
IV – 50%
SETTINGS
*In disable mode the lamp(s) will always be on with motion detected and operate at 100%
light output, even in bright daylight.
Detection Area
1 2
I100%
II 75%
III 50%
IV 10%
Hold time
123
I5s
II 30s
III 1min
IV 5min
V10min
VI 20min
VII 30min
Daylight Sensor
1 2
IDisable
II 50Lux
III 10Lux
IV 2Lux
123
I0s
II 10s
III 1min
IV 5min
V10min
VI 30min
VII 1h
VIII +∞
1 2
I10%
II 20%
III 30%
IV 50%
Wiring with any 1~10V control gear to achieve dimming function.
This sensor is suitable for indoor use. Max. installation height is 6 meters.
99 190 13

AF-JA/JZ-211103
Malmbergs Elektriska AB, PO Box 144, SE-692 23 Kumla, SWEDEN
TROUBLE SHOOTING
Malfunction Cause Remedy
The load does not work
Incorrect light-control setting selected Adjust setting
Load faulty Replace load
Mains switched OFF Switch ON
The load is always on Continuous movement in the detection zone Check zone setting
The load is on without any
identifiable movement
The sensor is not mounted reliably for detecting
movement Securely mount enclosure
Movement occurred, but not identified by the sensor
(movement behind wall, movement of small object in
immediate lamp vicinity etc.)
Check zone setting
The load does not work despite
movement
Rapid movements are being suppressed to minimize
malfunctioning or the detection radius is too small Check zone setting
FUNCTIONS
3.1 100H burn-in mode for fluorescent lamp
With simple operation, rapidly turn off/on the fixture 3 cycles within 3 sec. (the green LED on the sensor flashes and the fixture
blinks 3 times to indicate the success of setup), lamp will be 100% on for 100 hours, and then automatically goes to sensor mode
after 100 hours. This is crucial to secure the lifetime of fluorescent lamp, when new fixture is installed, or old lamp is replaced.
This 100h burn-in feature can be cancelled by turning off/on the fixture 1 cycle within 1 sec.
3.2 Ambient daylight threshold
With simple operation, rapidly turn off/on the fixture 2 cycles within 2 sec:
a. The green LED on the sensor flashes slowly for 5 seconds, meanwhile the fixture blinks twice.
b. The daylight sensor measures and remembers the surrounding lux for 1 sec.
c. The fixture and green LED is on for 10s to indicate the success of learning.
This feature enables the fixture to function well in any real application circumstance, where the daylight penetrated into fixture may
vary a lot.
The latest surrounding lux value overwrites previous lux value learned.
Both the setting on DIP switch and the learned ambient lux threshold can overwrite each other. The latest action stays in validity.
3.3 Zero-cross relay operation
Designed in the software, the sensor switches on/off the load right on the zero-cross point, to ensure the min. current passing
through the relay contact point, and enable the max. load and life-time of the relay.
3.4 Loop-in and loop-out
Double “ L ” and “ N ” terminal makes it easy for wire loop-in and loop-out, saves the cost of terminal block and assembly time.
3.5 Manual override
This sensor reserved the access of manual override function for end-users to switch on/ off, or adjust the stand-by dimming level
with the push-switch. which makes the product more user-friendly and more options to fit for some extra-ordinary demands.
• short push (<1s): on/off;
ON
OFF: the light turns off immediately and can not be lit for a certain time (equals to hold time preset) even movement is
detected. After this period, the sensor goes to auto sensor mode.
OFF
ON: the light turns on 100% and goes to hold time period directly even when movement is detected. As soon as the
sensor goes to stand-by period, it can detect movement and turn on the light (100%) again (auto sensor mode).
• long push (>1s): dim up/down the stand-by dimming level from 10% to 50%. Both the setting on DIP switch and manual over-
ride can overwrite each other, the latest action stays in validity.
• if you do not want to have this manual override function, just leave this “push” terminal alone , not connected to any wire.
Note:
1. The motion sensor overrides daylight sensor, meaning the daylight sensor starts to check the ambient natural light only when the
lamp is switch off (motion hold-time elapsed).
2. This 1-10V output is non-isolated, please make sure the fixture is constructed according to relevant safety standard.
Table of contents
Other Malmbergs Security Sensor manuals
Popular Security Sensor manuals by other brands

Endress+Hauser
Endress+Hauser SOP300 Brief operating instructions

AMC
AMC SS14 manual

B.E.G.
B.E.G. LUXOMAT net PD2N-KNX-DX Mounting instructions

urmet domus
urmet domus 1051 Installation, programming and functions manual

Extronic
Extronic PD-22LF installation instructions

Optex
Optex CX-702 MKII installation guide