Mangar Health Raiser Lifting Cushion User manual

User Instrucons
Healthcare solutions designed for life
Raiser Liing Cushion
English
Deutsch

2
Table of Contents
Safety Informaon......................................................................................................... 3
Warnings........................................................................................................................ 3
Cauons.........................................................................................................................3
Product descripon....................................................................................................... 4
Intended Use ................................................................................................................. 4
Construcon...................................................................................................................4
StandardProductContents............................................................................................4
Installaon and use........................................................................................................ 5
GengStarted..............................................................................................................5
BaeryStatusIndicator.................................................................................................5
Connecng....................................................................................................................5
Operang......................................................................................................................6
Care and Maintenance.................................................................................................. 6
Cleaning.........................................................................................................................6
Maintenance...................................................................................................................7
Transportaon/Storage...................................................................................................7
Disposal/Recycling.........................................................................................................7
Troubleshoong.............................................................................................................8
Specicaons.................................................................................................................8
Appendices....................................................................................................................... 9
Spare parts..................................................................................................................... 9
Warranty.........................................................................................................................9
DeclaraonofConformity..............................................................................................18
English

Healthcare solutions designed for life
3
Safety Informaon
Ensure that you read and understand this instrucon manual before using
this product. Failure to follow the instrucons and safety precauons in
this manual can result in damage and/or serious injury.
Please keep these instrucons in a safe locaon for future reference
WARNINGS (Risk of possible injury or other serious adverse reacons)
•DonotoperatetheAiro12compressorinthepresenceofammableanaesthecmixtures
withair,oxygenornitrousoxide,asthesemixturescancreateacombusbleenvironment
leadingtothepotenalforreorevenanexplosioninthepresenceofaspark.
•DonotusetheRaiserLiingCushionifundertheinuenceofalcoholoriftakingmedicaon
whichmayaectyourabilitytoexercisejudgment,coordinaonormotorcontrol.
•NEVERusetheRaiserLiingCushionasastep,standorasadeviceforliingitems.
•TheRaiserLiingCushionshouldonlybeusedforitsstatedpurposeandshouldnotbe
modiedinanyway.
•Ensurethatwheninuse,theAiro12compressor,thehandcontrolleadandairhosearelaid
outinsuchawayastoavoidanyriskoftrippingorstrangulaon.
•DonotallowchildrentoplaywiththeRaiserLiingCushionorAiro12asoperaonofthe
equipmentinanuncontrolledorunsupervisedsituaonmayleadtopersonalinjuryand/or
damage.
•Toavoidpersonalinjuryduringuseand/ordamagetotheequipment,keepanimalsaway
fromtheRaiserLiingCushionandAirocompressor.
•Regularlycheckthattherearenoobvioussignsofdamage.Ifindoubt,donotuseandseek
advicefromyoursupplier.
•IfTheRaiserLiingCushionistobeusedinachairwhichdoesnothavearmrests,theuser
MUSTassesstheirabilitytomaintainstabilitywhilstthecushionisbeingraisedandlowered.
•Toavoidtheriskofelectricshock,NEVERrechargetheAirobaeryinthebathroom,
outdoorsorinadampenvironment.
•DonotuseanyotherairsupplytoinatetheRaiserLiingCushion.
•EnsurethattheRaiserLiingCushionisprotectedfromsharpobjects.
CAUTIONS (Risk of possible problems including device malfuncons, device failure,
damage to the device or damage to other property)
•OnlyrechargethebaerywiththeMangarHealthbaerychargersuppliedwiththeAiro12
compressor.
•NeverusehotairtodrytheRaiserLiingCushionfollowingcleaningasthismayaectthe
integrityoftheweldedseamsandfabricandleadtoprematurefailureofthecushion.
•DisconnecttheAiro12compressorfromtheRaiserLiingCushionbeforetransporngsoas
toavoidaccidentalinaonofthecushion.
For further assistance or informaon please contact our Customer Service Department by
calling +44(0)1544 267674 or email sales@mangarhealth.com
English

4
Product Descripon
Intended Use
TheRaiserLiingCushionisintendedsolelyforuseasaliingaidtoassistapersontoraise
themselvesfromandlowerthemselvesintoanarmchair.Usersshouldhavesucientupperbody
strengthtobeabletoholdthearmrestsforaddedsupportifrequired.WARNING:IfTheRaiser
LiingCushionistobeusedinachairwhichdoesnothavearmrests,theuserMUSTassesstheir
abilitytomaintainstabilitywhilstthecushionisbeingraisedandlowered.TheRaiserLiing
Cushionisnotintendedforanyotheruseandshouldneverbeusedasasteporforliingitems.
Whenproperlymaintained,theRaiserLiingCushionwillgivemanyyearsoftroublefreeservice.
Construction
TheRaiserLiingCushionisconstructedfromaverystrongpolyurethanecoatednylonmaterial
whichhasbeenprecisioncutintopanelsandthenjoinedtogetherbyhighfrequencywelding.
Thisproducesaverystronglightweightandairghtconstrucon.TheRaiserLiingCushion
incorporatesaquickexhaustvalvewhichallowsthecushiontofullydeatewithouttheneedto
keeppressingthedownbuononthehandcontrol.
TheRaiserLiingCushionispoweredbythe
MangarHealthAiro12baerypowered
compressor.PLEASEREADtheseparateAiro
12compressorinstruconsbeforeusingyour
RaiserLiingCushion.
Standard Product Contents
1xRaiserLiingCushion
1xUserInstrucons
English

Healthcare solutions designed for life
5
Installaon and Use
Geng Started
TheAiro12doesnothavean‘on/o’switch.
Tooperatethecompressor,pressthe‘Up’
buonontheAirooronthehandcontrol.
English
A
B
‘Up’ ‘Down’
Connecng
•PosiontheRaiserLiingCushiononthe
chairsothattheairhoseisattherear.
•Connecttheairhose(A Fig. 1)andthe
handcontrollead(B)totheAiro12.
•Placethehandcontrolwithineasyreach.
1

6
Care and Maintenance
Cleaning
Roune cleaning
•FullyinatetheRaiserLiingCushionforcleaning.
•Allcomponentscanbecleanedwithaproprietarynon-abrasivemildliquidcleaneror
disinfectant.Alwaysfollowpackaginginstruconsforusingmilddetergentproducts.
NOTE: Beforeusingproprietarycleaners,alwaystestonaninconspicuousarea.
•Useasoclothwhencleaning.
•Donotwashtheproductinboilingwater.
IMPORTANT:Followingcleaning,rinsethoroughlywithcleanwatertoremoveallsoapdeposits.
Wipedryorleavetoairdry.NeverstoretheRaiserLiingCushionwhenitiswetordamp.Donot
leaveinbrightsunlight.Do not dry using hot air.
Operang - (Figs. 2 & 3)
WARNING:IfTheRaiserLiingCushionistobe
usedinachairwhichdoesnothavearmrests,
theuserMUSTassesstheirabilitytomaintain
stabilitywhilstthecushionisbeingraisedand
lowered.
•Keep your feet rmly on the oor, slightly
apart and as close to the front of the
armchairaspossible.
•Withyourhandsonthearmreststosteady
yourself, lean forward and transfer your
weighttothefrontoftheseat.
•To rise, press and hold the ‘Up’ buon on
thehandcontrol.Releasethebuontostop
atanyheight.
•Tolower,press‘Down’onthehandcontrol.
Tostoploweringatanypoint,momentarily
pressthe‘Up’buon.
•Aer leaving the seat, press and hold the
‘Down’buonunltheinialreleaseofair
hasoccurred.TheRaiserLiingCushionwill
carryondeangaerthe‘Down’buonis
released,readyforwhenthecushionisnext
used.
NOTE:Iftheairhoseisdisconnected,theRaiser
LiingCushionwilldeate.
3
2
English
UP DOWN

Healthcare solutions designed for life
7
Care and Maintenance
Disinfecon
•TheRaiserLiingCushionshouldbefullyinatedandpre-cleanedbywashingwithdetergent
andwater,thoroughlyrinsedandthendisinfectedusinga1:10soluonofhouseholdliquid
bleachandwater(1partbleachto10partscoldwater).LeavethesoluonontheRaiser
LiingCushionforapproximately10minutesbeforethoroughlyrinsingowithcleancold
water.
WARNING:Nevermixbleachwithanyothercleaningproductasdoingsocanresultinthe
formaonofharmfulacidsandpoisonousgaseswhichcancauseseriousbreathingproblems.
Maintenance
Otherthanrounecleaninganddisinfecng,theRaiserLiingCushionismaintenancefree.
Mangar Health recommends that your Raiser Liing Cushion is inspected annually by either
your supplier or other suitably qualied person. If required, Mangar Health or our authorised
representave,canprovideaninspeconwithinanannualservicecontract.Pleasecontactour
CustomerServiceDepartmentforfurtherdetails.
Transportaon / Storage
DisconnecttheAiro12compressorfromtheRaiserLiingCushionbeforetransporngsoasto
avoidaccidentalinaonofthecushion.
EnsurethattheRaiserLiingCushioniscleanandthoroughlydrybeforestoring.Failuretothoroughly
drythecushionbeforestoragemayresultinabuild-upofmouldonthesurfaceoftheproduct
leadingtoaweakeningofthefabricandconsequenalinvalidaonoftheproductwarranty.Store
inadryenvironment.
TomaintaintheAirobaerywhenbeingstoredforlongperiods,puttheAiroonchargefor16
hoursevery3months.
Disposal / Recycling
WhentheRaiserLiingCushionhasreachedtheendofitsworkinglife,disposeofitatyourlocal
householdwasterecyclingcentre(civicamenitysite).
WhentheAirohasreachedtheendofitsworkinglife,removethebaeryforsafedisposalin
accordancewithyourlocalcouncilguidelines,anddisposeoftheAiroatyourlocalhousehold
wasterecyclingcentre(civicamenitysite).
English

8
Care and Maintenance
= 2m
Specicaons
Max.userweight: 190kg(30st)
Inatedheight: 23cm
Inatedwidth: 43cm
Inatedlength: 43cm
Productweight: 0.60kg
Max.inletpressure: 0,35bar(5psi)
Max/Mintemperature: +50ºC/-15ºC
43cm
43cm
23cm
English
Trouble shoong guide
Problem Remedy
•Compressor does not run when ‘up’ is
selected.
•Ensure that the air hose from the product
being inated is connected to the Airo.
•Check that there are no kinks in the air hose.
•Compressor keeps stopping when trying to
inate the liing aid. •Check that there are no kinks in the air hose.
•Boom Baery Status Indicator light solid
‘Red’ and product will not deate.
•Low baery capacity, recharge for a
minimum of 2 hours.
•Boom Baery Status Indicator ashing red
every 2 seconds.
•Internal pump temperature too high - allow a
cool down period of 60-90 minutes.
•Boom Baery status indicator ashing Red
every ½ second.
•Current overload. Check there are no kinks in
in the air hose.
•Compressor causes electrical interference
with another piece of electrical equipment.
•Move either the compressor or other item
further away from each other unl the
interference stops.

Healthcare solutions designed for life
9
Appendices
RaiserLiingCushionserialnumber:..............................
Dateofpurchase: ..............................
Invoice/Deliverynotenumber: ...............................
Warranty
Thewarrantyisgivenagainstdefectsinmaterialandworkmanshipandcomprisespiece,partsand
labour.Thewarrantyisnotvalidinthecaseoffairwearandtear,wilfuldamage,commonneglect,
misuseorunauthorisedalteraonorrepairbyunqualiedpersons.
Thefollowingstatementsdonotaecttheconsumer’sstatutoryrights.Thisproductissoldonthe
understandingthatinthe eventof anydefect of manufactureor materialappearing within the
warrantyperiod,thedefectwillberecedfreeofchargeprovidingthat:
(a) Reasonableevidenceisprovided(e.g.purchaseinvoice,deliverynote)thattheclaimisbeing
madewithinthewarrantyperiod.
(b) Thedefectisnotaributabletoaccidentaldamage(eitherintransitorotherwise),misuse
orunauthorisedrepair.
Intheeventofawarrantyclaim,pleasecontactyoursupplier.Afullwarrantystatementcanbe
obtainedbycontacngMangarHealthon+44(0)1544267674oremail[email protected]om
Spare Parts
English
Connector
PartCode:CA0446
MangarInternaonal,tradingasMangarHealth,reservestherighttoalterproductspecicaonsand/oranyoftheinformaon
containedwithinthisdocumentwithoutnoce.

10
Inhaltsverzeichnis
Sicherheitshinweise............................................................................................... 11
Warnhinweise............................................................................................................... 11
Vorsichtshinweise......................................................................................................... 11
Produktbeschreibung ............................................................................................ 12
Verwendungszweck ..................................................................................................... 12
Auau .......................................................................................................................... 12
Standard-Lieferumfang................................................................................................. 12
Vorbereitung und Verwendung ............................................................................ 13
ErsteSchrie ................................................................................................................ 13
KontrollleuchtefürAkkuladestand............................................................................... 13
Anschlüsse .................................................................................................................... 13
Betrieb .......................................................................................................................... 14
Pege und Wartung............................................................................................... 14
Reinigung ...................................................................................................................... 14
Wartung........................................................................................................................ 15
Transport/Lagerung...................................................................................................... 15
Entsorgung/Recycling................................................................................................... 15
Fehlerbehebung ........................................................................................................... 16
TechnischeDaten ......................................................................................................... 16
Anhänge.................................................................................................................. 17
Ersatzteile ..................................................................................................................... 17
Garane ........................................................................................................................ 17
Konformitätserklärung ................................................................................................. 18
Deutsch

Healthcare solutions designed for life
11
Sicherheitshinweise
Lesen Sie sich diese Bedienungsanleitung vor Gebrauch dieses Produkts durch.
Bei Nichtbeachtung der Anweisungen und Sicherheitshinweise in dieser
Anleitung kann es zu Schäden und/oder schweren Verletzungen kommen.
Bewahren Sie diese Anleitung zur späteren Verwendung an einem sicheren Ort auf.
WARNHINWEISE (Gefahr einer möglichen Verletzung oder von anderen schweren Neben-
wirkungen)
•VerwendenSiedenAiro12KompressornichtinGegenwartvonbrennbarenAnästhekagemischenmit
Lu,SauerstooderDisckstooxid,dadieseGemischeleichtenlammbarsindundzuBrandgefahr
oderauchExplosionsgefahrdurchFunkenugführenkönnen.
•Verwenden Sie das Raiser Hebekissen nicht unter Alkoholeinuss oder wenn Sie Medikamenten
einnehmen,dieIhrUrteilsvermögen,IhreKoordinaonoderIhremotorischenFähigkeiteneinschränken.
•VerwendenSiedasRaiserHebekissenNIEalsTri,StänderoderzumHebenvonGegenständen.
•DasRaiserHebekissensolltenurfürdenvorgesehenenZweckverwendetwerdenunddarfinkeinster
Weisemodiziertwerden.
•AchtenSiedarauf,dassbeiVerwendungdesAiro12KompressorsdasKabelzurHandbedienungund
derLuschlauchsogeführtwerden,dasskeineKipp-oderStrangulaonsgefahrbesteht.
•LassenSieKindernichtmitdemRaiserHebekissenoderdemAiro12spielen,dadieunkontrollierte
undunbeaufsichgteAnwendungdesProduktszuPersonen-und/oderSachschädenführenkann.
•UmVerletzungenwährenddesGebrauchsund/oderSchädenamGerätzuvermeiden,haltenSieTiere
vomRaiserHebekissenundAiroKompressorfern.
•PrüfenSiedasRaiserHebekissenregelmäßigaufoensichtlicheAnzeichenfürSchäden.ImZweifelsfall
verwendenSiedasHebekissennicht,sondernbienSieIhrenFachhändlerumRat.
•SolldasRaiserHebekissenaufeinemStuhlohneArmlehnenverwendetwerden,MUSSderBenutzer
prüfen,obderStuhlbeimAulasenundAbsenkendesKissensausreichendeStabilitätaufweist.
•UmdieGefahreineselektrischenSchlagszuvermeiden,ladenSiedenAkkudesAiroNIEimBadezimmer,
imFreienoderineinerfeuchtenUmgebungauf.
•VerwendenSiezumAulasendesRaiserHebekissenskeineandereLuzufuhr.
•Achten Sie darauf, dass das Raiser Hebekissen vor spitzen und/oder scharfen Gegenständen
geschütztwird.
VORSICHTSHINWEISE (Gefahr des Auretens von Problemen wie Fehlfunkonen, Geräteaus-
fall, Schäden am Gerät oder anderen Sachschäden)
•LadenSiedenAkkunurmitdemMangarHealthLadegerätauf,welchesimLieferumfangdesAiro12
Kompressorsenthaltenist.
•VerwendenSiezumTrocknendesRaiserHebekissensnachderReinigungnieHeißlu,dadies
dieSchweißnähteunddasGewebedesKissensschädigenunddieLebensdauerdesKissens
verkürzenkann.
•TrennenSiedenAiroKompressorvordemTransportvomRaiserHebekissen,umeinversehentliches
AulasendesKissenszuvermeiden.
Weitere Unterstützung und Informaonen erhalten Sie bei Ihrem Fachhändler.
Deutsch

12
Produktbeschreibung
Verwendungszweck
DasRaiserHebekissendientausschließlichalsHebehilfebeimHinsetzenundAufstehen.
DieBenutzersolltenüberausreichendKraimOberkörperverfügen,umsichbeiBedarfan
Armlehnenzusätzlichabstützenzukönnen.WARNUNG:SolldasRaiserHebekissenaufeinem
StuhlohneArmlehnenverwendetwerden,MUSSderBenutzerprüfen,obderStuhlbeim
AulasenundAbsenkendesKissensausreichendeStabilitätaufweist.DasRaiserHebekissenist
fürkeinenanderenVerwendungszweckvorgesehenundsollteniealsTrioderzumHebenvon
Gegenständenverwendetwerden.BeiordnungsgemäßerPegekanndasRaiserHebekissenviele
Jahrestörungsfreiverwendetwerden.
Aufbau
DasRaiserHebekissenbestehtauseinemsehrfesten,mitPolyurethanbeschichteten
Nylonmaterial,welchesdurchPräzisionsschneideninSegmenteunterteiltwurde.DieSegmente
wurdenanschließenddurchHochfrequenzschweißenwiederzusammengefügt.Dadurchentsteht
einesehrhaltbare,leichteundludichteKonstrukon.DasRaiserHebekissenumfasstein
Schnellentlüungsvenl,überdasdieLuvollständigausdemKissenentweicht,ohnedassdie
TastezumAblassenderLuanderHandbedienunggedrücktgehaltenwerdenmuss.
DieStromversorgungfürdasRaiserHebekissen
erfolgtüberdenvomMangarHealthAiro12
AkkugespeistenKompressor.BITTELESENSIE
sichvorGebrauchdesRaiserHebekissensdie
separateBedienungsanleitungzumAiro12
Kompressordurch.
Standard-Lieferumfang
1xRaiserHebekissen
1xBedienungsanleitung
Deutsch

Healthcare solutions designed for life
13
Vorbereitung und Verwendung
Anschlüsse
•LegenSiedasRaiserHebekissensoaufden
Sessel/Stuhl,dassderAnschlussfürden
Luschlauchnachhintenweist.
•SchließenSiedenLuschlauch(A Abb.1)
unddasKabelzurHandbedienung(B) an
denAiroan.
•LegenSiedieHandbedienunggriereit
beiseite.
Deutsch
Erste Schrie
DerAiro12verfügtüberkeinenEin/Aus-Schalter.
ZumBetriebdesKompressorsdrückenSiedieTaste
“Auf“aufdemAirooderderHandbedienung.
‘Auf’‘Ab’
A
B
1

14
Pege und Wartung
Reinigung
Regelmäßige Reinigung
• BlasenSiedasRaiserHebekissenzurReinigungvollständigauf.
• AlleTeilelassensichmiteinemnichtscheuerndenmildenundüssigenMarkenreinigungs-oder
Desinfekonsmielreinigen.WendenSiedasjeweiligemildeReinigungsmielstetsnachden
AnweisungenaufderVerpackungan.
HINWEIS: TestenSieMarkenreinigungsmielvorderAnwendungstetsaneinerunauälligen
Stelle.
• VerwendenSiezumReinigeneinweichesTuch.
• WaschenSiedasProduktnichtinkochendemWasser.
WICHTIG:SpülenSiedasProduktnachderReinigunggründlichmitsauberemWasserab,umalle
Seifenrückständezuenernen.TrocknenSieesaboderlassenSieesanderLutrocknen.LagernSie
dasRaiserHebekissennieimnassenoderfeuchtenZustand.LassenSiedasKissennichtlängereZeit
inprallerSonneliegen.Trocknen Sie das Kissen nicht mit Heißlu.
Betrieb - (Abb. 2 und 3)
WARNUNG:SolldasRaiserHebekissenaufeinem
StuhlohneArmlehnenverwendetwerden,MUSS
derBenutzerprüfen,obderStuhlbeimAulasen
undAbsenkendesKissensausreichendeStabilität
aufweist.
• Stellen Sie die Füße mit etwas Abstand
zueinander möglichst dicht vor dem Sessel/
StuhlfestaufdenBoden.
• Halten Sie sich mit den Händen an den
ArmlehnenfestundlehnenSiesichnachvorne,
umdasGewichtaufdenvorderenBereichder
Sitzächezuverlagern.
• ZumAufstehenhaltenSiedieTaste“Auf“ander
Handbedienung gedrückt. Der Anhebevorgang
stoppt,sobaldSiedieTasteloslassen.
• Zum Hinsetzen drücken Sie “Ab“ an der
Handbedienung. Den Absenkvorgang können
Sie jederzeit abbrechen, indem Sie kurz die
Taste“Auf“drücken.
• Nachdem Sie vom Sessel/Stuhl aufgestanden
sind, halten Sie die Taste “Ab“ gedrückt, bis
die Lu zu entweichen beginnt. Das Raiser
Hebekissen lässt die Lu auch nach Loslassen
der Taste “Ab“ weiter ab und ist anschließend
bereitfürdennächstenGebrauch.
HINWEIS: Wird der Luschlauch vom Kissen
getrennt, entweicht die Lu aus dem Raiser
Hebekissen.
Deutsch
3
2
AUF AB

Healthcare solutions designed for life
15
Pege und Wartung
Desinfekon
•DasRaiserHebekissensolltevollständigaufgeblasenunddurchAbwaschenmitReinigungsmiel
undWasservorgereinigtwerden.Anschließendsollteesgründlichabgespültunddannmiteiner
haushaltsüblichenFlüssigbleichmiellösungimVerhältnis1:10(1TeilBleichmielauf10Teile
kaltesWasser)desinziertwerden.LassenSiedieLösungamRaiserHebekissenetwa10Minuten
langeinwirken,bevorSiesiemitsauberemkaltenWassergründlichabspülen.
WARNUNG:MischenSieBleichmielniemitanderenReinigungsprodukten,dadadurchschädliche
SäurenodergiigeGaseentstehenkönnen,diezuschwerenAtemproblemenführenkönnen.
Wartung
AbgesehenvonderregelmäßigenReinigungundDesinfekonistdasRaiserHebekissenwartungsfrei.
MangarHealthempehlt,dasRaiserHebekissenjährlichentwedervoneinemFachhändlerodereiner
anderenadäquatqualiziertenPersonüberprüfenzulassen.
Transport/Lagerung
TrennenSiedenAiro12KompressorvordemTransportvomRaiserHebekissen,umeinversehentliches
AulasendesKissenszuvermeiden.
Stellen Sie sicher, dass das Raiser Hebekissen vor der Lagerung sauber und vollständig trocken ist.
WurdedasKissenvorderLagerungnichtgründlichabgetrocknet,kannsichaufderProduktoberäche
Schimmelbilden.DadurchwirddasGewebegeschwächtunddieProduktgaraneerlischt.LagernSie
dasKissentrocken.
LadenSiefüreinenopmalenUmgangmitdemAkkudenAiro12Akkubeieinerlängerfrisgen
Lagerungalle3Monatefür16Stunden.
Entsorgung/Recycling
WenndasRaiserHebekissendasEndeseinerNutzdauererreichthat,entsorgenSieesbeiIhrer
örtlichenHaushaltsmüll-Recyclingstaon(Wertstoof).
WennderAirodasEndeseinerNutzdauererreichthat,entnehmenSiedieAkkus,umdiesesicher
undgemäßdenkommunalenRichtlinienzuentsorgen,undentsorgenSiedenAirobeiIhrer
örtlichenHaushaltsmüll-Recyclingstaon(Wertstoof).
Deutsch

16
Pege und Wartung
= 2m
Technische Daten
Max.Benutzergewicht: 190kg
Höhe(aufgeblasen): 23cm
Breite(aufgeblasen): 43cm
Länge(aufgeblasen): 43cm
GewichtdesKissens: 0,60kg
Max.Einlassdruck: 0,35bar
ZulässigeHöchst-/
Tiefsemperatur: +50°C/-15°C
43cm
43cm
23cm
Deutsch
Fehlerbehebung
Problem Abhilfemaßnahme
•Der Kompressor läu nicht, wenn die Taste
„Auf” akviert wird.
•Stellen Sie sicher, dass der Luschlauch
des aufzublasenden Produkts am Airo 12
angeschlossen ist.
•Stellen Sie sicher, dass der Luschlauch nicht
abgeknickt ist.
•Der Kompressor stoppt immer wieder bei
dem Versuch, die Hebehilfe aufzublasen.
•Stellen Sie sicher, dass der Luschlauch nicht
abgeknickt ist.
•Die Akkuladstandsanzeige zeigt eine
dauerha leuchtende rote LED und die
Lu kann nicht aus der Hebehilfe gelassen
werden.
•Niedriger Akkuladestand – Laden Sie das
Gerät mindestens 2 Stunden auf.
• Die unterste Leuchte der
Akkuladestandsanzeige blinkt alle 2 Sekunden
rot.
•Interne Pumpentemperatur zu hoch – Lassen
Sie den Airo 60-90 Minuten abkühlen.
• Die unterste Leuchte der
Akkuladestandsanzeige blinkt alle 0,5
Sekunden rot.
•Stromüberlastung. Stellen Sie sicher, dass der
Luschlauch nicht abgeknickt ist.
•Der Kompressor verursacht elektrische
Störungen bei einem anderen Elektrogerät.
•Versetzen Sie entweder den Kompressor oder
das andere Elektrogerät, bis der Abstand groß
genug ist, dass die Interferenzen auören.

Healthcare solutions designed for life
17
Anhänge
SeriennummerdesRaiser
Hebekissens: ..............................
Kaufdatum: ..............................
Rechnungs-/Lieferscheinnummer: ...............................
Garane
Die Garane wird in Bezug auf Materialfehler und Herstellungsmängel gewährt und umfasst
das Zubehör, die Komponenten und die Arbeit. Die Garane gilt nicht bei üblichem Verschleiß,
mutwilligerBeschädigung,Nachlässigkeit, Missbrauchoder unautorisiertenModikaonenoder
ReparaturendurchunqualiziertePersonen.
Die folgenden Aussagen haben keinen Einuss auf die gesetzlichen Rechte des Kunden. Dieses
ProduktwirdunterderPrämisseverkau,dasseinMaterialfehleroderHerstellungsmangel,der
innerhalb des Garanezeitraums auri, unter folgenden Voraussetzungen kostenfrei behoben
wird:
(a) EswirdeinadäquaterNachweiserbracht(z.B.Kaueleg,Lieferschein),dassdieBeanstandung
innerhalbdesGaranezeitraumserfolgt.
(b) DerDefektistnichtaufeinenUnfallschaden(wederwährenddesVersandsnochanderweig),
MissbrauchoderunautorisierteReparaturzurückzuführen.
WendenSiesichbeieinemGaraneanspruchanIhrenFachhändler.
Ersatzteile
Anschlussfüreinen
Art.-Nr.:CA0446
Deutsch

18
Appendices
MangarInternaonalLtdbehältsichunterdemHandelsnamenMangarHealthdasRechtvor,Produktspezikaonenund/oderjegliche
InformaonenindiesemDokumentohnevorherigeAnkündigungzuändern.
DECLARATION OF CONFORMITY
This is to cerfy that:-
The
Raiser Liing Cushion - HMA0100
complies with:-
The requirements for Class 1 devices according to Annex VII of the Medical
Devices Direcve 93/42/EEC as amended by 2007/47/EC
Mangar Internaonal Ltd
Presteigne, Powys, Wales,UK. LD8 2UF
tel: +44 (0)1544 267674
fax: +44 (0)1544 260287
heado[email protected]
www.mangarhealth.com
Signed:
Date: April 2017
C. Butcher (Finance Director)
Deutsch

Healthcare solutions designed for life
19
Appendices
Deutsch

Healthcare solutions designed for life
Mangar Internaonal Ltd
Presteigne, Powys, Wales, LD8 2UF
United Kingdom
Tel: +44 (0)1544 267674
Fax: +44 (0)1544 260287
E-mail: sales@mangarhealth.com
www.mangarhealth.com MI0364 issue 5
(11/20)
Table of contents
Languages:
Other Mangar Health Personal Care Product manuals
Popular Personal Care Product manuals by other brands

Philips
Philips HP4676 user manual

Orliman
Orliman SOFY-PLANT.gel Use and maintenance instructions

Kleine Wolke
Kleine Wolke LADY MIRROR operating instructions

Advanced Wireless Communications
Advanced Wireless Communications AW-NCB4100 user manual

Paingone
Paingone Paingone Plus manual

Radiancy
Radiancy FSD+ user manual