Description:
Quick Start Guide
HMC3043A-M
Specifications:
The HMC3043A-M is a combination operator-based HMI (Human
Machine Interface) with built-in PLC (Programmable Logic
Controller) operation. It communicates with external PLCs over
serial communications ports to read/write data. One I/O
expansion module can be attached.
Power: 24VDC +/- 15%, 8W (with 1
expansion)
Display: 4.3” TFT (480 x 272 pixels)
Color graphics display
Bezel: NEMA 4X (IP 66) rated
Touchscreen: 4-wire analog resistive
LEDs: One Power LED
CPU: 32-bit RISC, 454 MHz
Port Details (COM1 and COM2):
DE9S (Female) Connector
Note: This model has one physical connector that can be used as
COM1 (RS232) and COM2 (RS485/422) simultaneously, when a
HMC3043A-M 480x272 pixels, 4.3” color TFT, with one expansion
slot, an Ethernet port, and two serial ports* (see note under
pinout).
Memory: 45 MB Max. Application Memory
Ethernet (RJ45): One 10/100 Mbps port
Serial ports (DE9S): Two serial ports
“Y” adapter cable is used. Connect shell to shield of cable.
Grounding:
USB Slave (Micro Type B): (RS232/RS485/RS422) The HMC3043 should have a good electrical connection to earth
Contents: Upload/download projects
USB Host (Standard Type A): ground via the power connector for safety and to reduce electrical
—1 HMC3043A-M (in plastic bag with protective cover sheet
on the screen) SD card:
Expansion ports:
Data storage
Micro SD (high capacity: 4-32 GB)
HMC3 I/O
noise. The HMC unit should be grounded separately from other
high-power systems.
—1 plastic bag containing 4 mounting clamps (each clamp
consisting of cap nut, bolt, and clamp)
—1 three prong green power plug*
—Cardboard package inserts
One for optional
modules
Operating temp: 0 to 60° C
Humidity: 10% to 90% (non-condensing)
Dimensions (WxHxD): 4.72 x 3.50 x 1.24 inches
—Quick Start Guide
*Note: Connector manufacturer may vary.
Programming software (MAPware-7000), cables, and power
supply purchased separately.
Panel Mounting and Panel Cutout:
Panel cutout:
Mounting Unit to Panel:
[120 x 89 x 31.5mm]
4.37 x 3.14 inches [111 x 80mm]
Note: Do not use a ground connection that has potential
impedance (such as painted screws) or is subject to vibration.
Expansion I/O Modules:
The HMC3043A-M has one expansion slot that you can use to
connect I/O modules. Below is a listing of modules currently
available (consult Maple Systems website for additional
information).
HMC3-M1616P: 16 digital input, 16 PNP-type digital
output
Tighten the mounting screws evenly to a torque between 0.4 and 0.5
Nm to maintain water and dust resistance. Make sure the panel is not
dirty and warped and that it is strong enough to hold the unit.
Note: Maximum panel thickness (on which unit is to be mounted)
should be 6.0 mm (Tolerance: +/-0.2 mm).
Step 1: Place unit into cutout of panel and position mounting
clamps (4) into the side slots of HMC3043 enclosure as shown.
Step 2: Tighten clamps evenly to prevent warping. Continue to
tighten until a torque force of 0.4-0.5 Nm is obtained.
Step 3: HMC3043 should be aligned evenly with the cutout with
no warping present after clamps are tightened.
HMC3-M1614Y: 16 digital input, 14 digital output
(12 relay, 2 PNP-type)
HMC3-M1212P0200: 12 digital input, 12 PNP-type digital
output, 2 analog input
HMC3-M1212Y0200: 12 digital input, 12 digital output
(10 relay, 2 PNP-type), 2 analog
input
HMC3-M1210P0201: 12 digital input, 10 PNP-type digital
output, 2 analog input and 1 analog
output.
HMC3-M1210Y0201: 12 digital input, 10 digital output (8
relay, 2 PNP-type), 2 analog input,
and 1 analog output.
HMC3-M0808P0401T: 8 digital input, 8 PNP-type digital
output, 4 analog input and 1 analog
output.
HMC3-M0808Y0401T: 8 digital input, 8 digital output (6
relay, 2 PNP-type), 4 analog input,
and 1 analog output.
Doc. No. 1011-0301 Maple Systems, Inc. 808 134th St SW, Suite 120, Everett, WA 98204-7333 www.maplesystems.com Rev 02, 11/29/2018
Getting Started:
Perform the following steps to configure and use the HMC3000
Series unit:
1.
Install MAPware-7000 software.
2.
Create your project.
3.
Connect a programming cable (USB or Ethernet).
4.
Save your project.
5.
Download project to HMC3043 (note: you must select the
Download Firmware option for the initial download).
6.
The HMC3000 unit is ready to use in the system.
PC Requirements for MAPware-7000:
Processor: 1 GHz Pentium-based processor or equivalent
Operating System: Microsoft Windows 7 or 10
RAM: 1 GB
Hard Disk: 800 MB (including 200 MB for the .NET Framework
Redistributable)
Display: 1024x768 high color 16-bit
Mouse/Keyboard: Required
USB or Ethernet port: for project downloads
Installing the Software:
1.
Insert MAPware-7000 CD into CD-ROM drive and follow
instructions.
2.
If software installation does not automatically start, click
\SETUP.EXE from CD directory.
PLC Connecting Cables:
Contact Maple Systems to order any PLC Communications
Cables or to download a cable pinout diagram.
Additional Resources:
Detailed instructions on the operation and installation of the
HMC3000 Series are available in the HMC3000 Programming
Manual that is included with the MAPware-7000 configuration
software. MAPware-7000 also includes help files that provide
detailed information on using the configuration software.
Other Sources (visit Maple Systems Support Center website):
—Controller Information Sheets- specific information on
connecting a particular manufacturer's PLC to the HMC3000
—Cable Drawings- wiring diagrams to particular PLCs
—Technical Notes- Provides additional information and examples
not covered in the operations manual
—Software Upgrades- Upgrades to the MAPware-7000 software
Class I Division 2 Wiring Considerations:
Capacitance and inductance of the field wiring from the
nonincendive equipment to the associated apparatus shall be
calculated and must be included in the system calculations as
shown in Table 1.
Where the cable capacitance and inductance per foot are not
known, the following values shall be used: Ccable = 60 pF/ft,
Lcable = 0.2 µH/ft.
TABLE 1:
Wiring method must be in accordance with ANSI/NFPA70.
This equipment is suitable for use in Class I, Division 2, Groups A,
B, C and D or non-hazardous locations only.
WARNING – EXPLOSION HAZARD – Do not disconnect
equipment unless power has been removed or the area is known
to be non-hazardous.
WARNING – EXPLOSION HAZARD - Substitution of
components may impair suitability for Class I, Division 2.
WARNING - CAUTION, battery may explode if mistreated. Do
not recharge, disassemble or dispose of in fire.
It is recommended that the user periodically inspect the sealed
devices used, check for any degradation of properties, and
replace as necessary.
For Technical Support:
Please contact Maple Systems if you have any questions
regarding this product. We ask that you provide us with the unit
serial number and firmware revision number written on the
product label of the unit.
Maple Systems Inc.
808 134th St. SW, STE 120
Everett, WA 98204
Tel: 425-745-3229
Fax: 425-745-3429
Email: support@maplesystems.com
Website: www.maplesystems.com
Doc. No. 1011-0301 Maple Systems, Inc. 808 134th St SW, Suite 120, Everett, WA 98204-7333 www.maplesystems.com Rev 02, 11/29/2018

Other Maple Systems Touchscreen manuals

Maple Systems HMC3102A-M User manual

Maple Systems

Maple Systems HMC3102A-M User manual

Maple Systems Silver Series User manual

Maple Systems

Maple Systems Silver Series User manual

Maple Systems HMC3070A-M User manual

Maple Systems

Maple Systems HMC3070A-M User manual

Popular Touchscreen manuals by other brands

Advantech IDP31-215W Series user manual

Advantech

Advantech IDP31-215W Series user manual

Crestron TSW-550 Configuration guide

Crestron

Crestron TSW-550 Configuration guide

Elo TouchSystems 2639L Product dimensions

Elo TouchSystems

Elo TouchSystems 2639L Product dimensions

Edge Products CS user guide

Edge Products

Edge Products CS user guide

Elo TouchSystems 1515L Technische Daten

Elo TouchSystems

Elo TouchSystems 1515L Technische Daten

Elo TouchSystems 1928LM Guide

Elo TouchSystems

Elo TouchSystems 1928LM Guide

Spring Air Systems Truflow-TC Installation and operation manual

Spring Air Systems

Spring Air Systems Truflow-TC Installation and operation manual

Furuno TZT9F Operator's guide

Furuno

Furuno TZT9F Operator's guide

Crestron TSW-750 quick start guide

Crestron

Crestron TSW-750 quick start guide

HORNER XL7 quick start guide

HORNER

HORNER XL7 quick start guide

Magenta Mondo TC Quick reference & setup guide

Magenta

Magenta Mondo TC Quick reference & setup guide

Matrix Orbital HTT Series Firmware Guide

Matrix Orbital

Matrix Orbital HTT Series Firmware Guide

Elo TouchSystems 1930L user manual

Elo TouchSystems

Elo TouchSystems 1930L user manual

Phonak Roger Touchscreen How to connect

Phonak

Phonak Roger Touchscreen How to connect

AIS OF15T100-A1-PCT user guide

AIS

AIS OF15T100-A1-PCT user guide

Avalue Technology HID-2100 user manual

Avalue Technology

Avalue Technology HID-2100 user manual

Elo TouchSystems ET1724L-7SWR-1-NL, ET1724L-8SW user guide

Elo TouchSystems

Elo TouchSystems ET1724L-7SWR-1-NL, ET1724L-8SW user guide

Tyco Electronics 1525L Series user guide

Tyco Electronics

Tyco Electronics 1525L Series user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.