Marel M2200 User manual

User’s Guide
M2200
P02 1013 Application
Marel hf.
Austurhraun 9 iIS-210 Gardabaer iICELAND
Tel: +354 563 8000 iFax: +354 563 8001
Version 1.00

Information in this document is subject to change without further notice, and does not
represent a commitment by Marel hf. No part of this document may be reproduced,
stored in a retrieval system, or transmitted in any form or by any means, electronic,
mechanical, photocopying or otherwise, without the prior
written permission of Marel hf.
Marelis a registered trademark of Marel hf.
Printed in Iceland, February 2003.
Copyright 2003, Marel hf. All rights reserved.
030224ENG

Contents
P02 1013 Application 1
IN GENERAL ...........................................................................................................1
ABOUT P02 1013 ....................................................................................................1
USING P02 1013 .....................................................................................................1
Starting Up.................................................................................................................. 1
The Scale page ............................................................................................................ 3
The Application Page.................................................................................................. 3
HOST INTERFACE ..................................................................................................4
Specific Interface ........................................................................................................ 4
Packing Scale Contents •i

ii •Contents M2200 P02

P02 1013 Application
In General
This is a technical description of the M2200-P02 1013 application.
The application’s Lua source code is available from Marel hf free of
charge but subject to conditions. For more information please contact
The “Programming” chapter of the M2200 P02 & M02 Packing Scale
User’s Guide contains more information on Lua scripts and M2200
programming.
About P02 1013
P02 1013 is an application for a stand-alone M2200 packing scale
without any controls.
Using P02 1013
Starting Up
To start using the P02 1013 application for the first time you must start
by setting the application parameters.
Packing Scale P02 1013 Application •1

To set the application parameters
Figure 1 The Top Level Menu
p
age.
1 Press and hold the PAGE key for ca. three seconds to display
the Top Level Menu page.
2 Select 4–System Setup ÆSettings ÆSystem parameters A.
Figure 2 Parameter list A.
3 Select a line in the parameter list, press the CHECK key to
enter a value for the parameter, and then confirm by pressing
again.
4 Press to return to the parameter list.
Note: You must scroll down with the arrow keys to see all
parameters in the list.
5 When you have finished setting all system parameters, press
once and select the Parameters option on the Settings
menu to create a new product.
To create a new product
For details on how to create products, see instructions in
“Creating Products” on page 12 in the M2200 P02 & M02
Packing Scale, User’s Guide.
♦
Available parameters:
Parameter: Description:
Accept all weights If this option is selected, the application will record
packs without regard to packing limits.
Send weight
messages to port 1
If this option is selected, the application will send
weight messages to serial port 1.
Send weight
messages to
pqueue
If this option is selected, the application will send
weight messages to the persistent output queue.
2 •P02 1013 Application M2200 P02

The Scale page
The Scale page in P02 1013 shows the current product name (1), the
calculated/selected nominal weight (2), the packing bar (3), and the
weight display (4).
You can use the arrow keys to select the previous or the next product.
2
3
4
1
Figure 3 The P02 1013 application, Scale page.
The Application Page
From the Scale page press to display the Application display, which
gives access to two pages, the Data page and the Debug page.
Use the DEBUG and DATA keys to switch between pages.
1
2
3
Figure 4 The Application display, Data page.
46
5
Packing Scale P02 1013 Application •3

Data page On the Data page you can see the product identification (1), the total number
of packs (2), nominal and target weights, and the total weight for the product
(3).
• Use the arrow key to select another product to view its details.
• Press the CLEAR key (4) to clear data for the displayed product.
• Press the REPORT key (5) to generate a weight report to the scale’s
serial port 1.
• Press the DEBUG key (6) to switch to the Debug page.
Figure 5 The Application display, the Debug page.
Debug page The Debug page shows the currently active application’s name and version
number (1), the current weight on the platform (2), and the current state (3)
and emergency number (4).
5
4
3
2
1
Connection status
indicators
• The first character in the connection status string is “+” if there is an
active connection on the message port, otherwise the flag is set to “-”.
• The second character shows the same for the terminal port.
• The third character is “+” if the CAN unit is online, otherwise the flag is
set to “-”.
Press the DATA key (5) to switch to the Data page.
Host Interface
Specific Interface
Weight message from device
Depending on the weight message options specified (see page 2) a
message can be sent to serial port 1 and the persistent output queue every
time a pack is recorded.
The message format is:
4 •P02 1013 Application M2200 P02

W<TAB><Product name><TAB><Product ID><TAB><nominal weight>
<TAB><real weight><unit>
Example:
W Size B fillets 9 2.000kg 2.235kg
Packing Scale P02 1013 Application •5

6 •P02 1013 Application M2200 P02
Other manuals for M2200
1
Table of contents
Other Marel Scale manuals