Mars Air Systems BD22 Series User manual

BD22 Submittal Package
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ● www.marsair.com
© Copyright Mars Air Systems, LLC 2014
NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
for previously purchased equipment.
MARS AIR SYSTEMS, LLC ● GARDENA, CA ● USA
BD22 Unheated Series
Belt Drive 22
Industrial Air Curtain
Submittal Package
Submitted by:
Mars Air Systems, LLC
14716 S. Broadway
Gardena, CA 90248
P.O.#
S.Q.
Company
Print Name
Signature
Date
Company Seal or Stamp
(Electronic Signature Preferred)

BD22 Submittal Package
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ● www.marsair.com
© Copyright Mars Air Systems, LLC 2014
NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
for previously purchased equipment.
MARS AIR SYSTEMS, LLC ● GARDENA, CA ● USA
Table of Contents
Page # Content
3-4 BD22 Unheated Submittals
5 Typical Motor Control Panel Wiring Diagram
6-7 Accessory Installation Supplement
8-11 Installation, Operation and Maintenance
12-13 Troubleshooting Guide
14 Warranty
15-24 CSI Spec
25 Reference Links


BD22 (Belt Driven 22) Series
Unheated
Model Lengths 96” – 192”
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)532-3030 ● www.marsair.com
© Copyright Mars Air Systems, LLC 2014
NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
for previously purchased equipment.
MARS AIR SYSTEMS, LLC ● GARDENA, CA ● USA AR, 8/16/21
208/230v
(G)
460v
(H)
575v
(I)
BD2296-1U*-TS
28.0/26.0 14.0 10.3
BD22120-1U*-TS
42.0/40.0 20.0 15.6
BD22144-1U*-TS
42.0/40.0 20.0 15.6
BD22168-1U*-TS
55.0/51.0 25.5 20.2
BD22192-1U*-TS
55.0/51.0 25.5 20.2
* - Use corresponding letters in"Electrical Data" columns to complete the model numbers.
Alternate voltage codes with FLA (Full Load Amp) data:
380-415V/3Ø/50Hz (W) – 11.5A per motor (10HP), 15.5A per motor (15HP), 22.5A per motor (20HP)
Ampacity (MCA) = total FLA X 1.25
Electrical Data
(FLA)
Unit Voltage
(Voltage Code)
BD22
Series: BD22
96 1UHTS
LENGTH OF UNIT
# OF MOTORS
U = UNHEATED
VOLTAGE CODE
COLOR
EXAMPLE
Unheated Data Sheet
Applications: Environmental Separation: Max Height 24’ / Insect Control: Max Height 22’
Features:
10 to 20 HP continuous duty premium efficiency industrial motors
Motor shall be inverter rated totally enclosed fan cooled suitable for
continuous heavy-duty operation
Sleek self-contained one-piece heavy gauge corrosion proof paint lock metal
design
For Indoor/Outdoor Use
Heavy duty cabinet 16 gauge, 1 ½” square galvanized tube, cased with a
minimum 14-gauge galvanized steel panels
Belt drive unit for heavy duty industrial projects
Top mounting holes provided (3/4”)
Cabinet has sufficient strength for fastening to wall on both ends without
intermediate support.
Motor shall be internally mounted in the cabinet to prevent damage and to
eliminate the need for a belt guard, complying with OSHA requirements
Adjustable air discharge nozzle with 40° sweep front to back
Discharge nozzle shall be 5 inches wide and shall distribute a uniform outlet air
velocity pattern without the use of baffles or diverters
Adjustable perforated volume dampers capable of reducing air velocity up to 50%
Blower wheel shall be forward curved cold rolled steel, direct coupled, dynamically
balanced and furnished complete with blower wheel housing
Variable pitch sheaves adjustable to suit field conditions
Standard color is Titanium Silver
Rust preventative electrostatic polyurethane powder coating
12-month parts warranty
Freight Not Included (FOB Factory)
Proudly Made in the USA
Mars Recommended Accessories (See Submittals for additional details):
Door Limit Switches
o99-125, Industrial surface mounted magnetic switch (controller required)
Controllers
oMCP*-†U‡, Motor Control Panel, 120V control voltage (* = HP Code, † = # of Motors, ‡ = Voltage Code)
Note: possible HP Codes = H (10 HP), I (15 HP), J (20 HP)
oMCP-TD, Adjustable time delay, 1sec-100hr (panel required)
oMCP-24V, Low voltage control option (panel required)
oBMS-303, BMS for monitor and control (panel required with MCP-24V)
Note: Dry contact provided in panel for monitoring motor. 24Vac signal provided from panel for controlling motor
Sound Levels: (measured at 10’ in an open field)
10 HP Motor Unit = 75 dBA, 15 HP Motor Unit = 76 dBA, 20 HP Motor Unit = 77 dBA
BD22 (WindGuard)
Model Number
Nozzle Length
(in)
Length
(in)
Depth
(in)
Height
(in)
Motor
(hp)
Weight
(lbs)
Max Velocity
(fpm)
Max Volume
(cfm)
BD2296-1U*-T S 96 107 36 28 10 700 6000 16250
BD22120-1U*-T S 120 131 36 28 15 800 6000 20300
BD22144-1U*-T S 144 155 36 28 15 900 6000 24350
BD22168-1U*-T S 168 179 36 28 20 1000 6000 28400
BD22192-1U*-T S 192 203 36 28 20 1100 6000 32500
* - Use corresponding letters in "Electrical Data" columns to complete the
model numbers.
Note: Data above is for 60 Hz, 17% reduction in the performance data with 50 Hz.
Mechanical Data
Lab Data


Document No: ACC-IOM
Date: 04/13/2013
ACCESSORY INSTALLATION SUPPLEMENT
Door Limit and Magnetic Reed Switches
1. Mars door limit and magnetic reed switches are
available with NEMA 1, 4X and 7 ratings. Contact the
factory for additional ratings and details. (See FIG. 1
for typical single swing, hinged door type, door limit
switch installation)
FIG. 1
2. Use light gauge materials when field fabricating
brackets to activate and deactivate the door limit
switch(s). (FIG. 2) Figure 2 also shows the typical
installation of the combination plunger/roller type
NEMA 1 door limit switch, for all non-hinged style
doors.
FIG. 2
3. All wiring must be per local and NEC (National Electric
Code) codes.
4. Panels or controllers may be required. Refer to wiring
diagram inside the control panel box.
FIG. 3
FIG. 4

Document No: ACC-IOM
Date: 04/13/2013
Bracket Installation
1. Side Extension Plates: For doorways wider than the air
curtain, use combination of Side Extension Plates and
Adjustable Mounting Brackets. (FIG. 5)
FIG. 5 (LPV SHOWN)
2. Adjustable Mounting Brackets: For installation of air
curtain over drum-style roll-up door, use Extended
Wall Mounting Brackets. (FIG. 6)
FIG. 6 (STD SHOWN)
3. Extended Wall Mounting: For Tandem Mounting of air
curtain over sectional style door, use either wall
mounting angle brackets or threaded rods.
4. Top Mounting Brackets: For overhead installation of
units, use in conjunction with the threaded holes
provided on top of unit.
Note: Angle brackets, threaded rods and I Beams are
provided by others. (FIGS. 7 & 8) All optional brackets
are not available for WMI/WMH and BD Series.
FIG. 7 (WMI/WMH Shown)
FIG. 8 (BD Shown)
14716 S. Broadway St., Gardena, CA 90248
(310) 532–1555 ● (800) 421-1266
Fax: (310) 324-3030
www.marsair.com

Document No: BD-IOM
Date: 08/25/20
WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES
Installation, Operation and Maintenance Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate, or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with these
instructions could result in personal injury and/or property damage. Retain these instructions for future reference.
OVERVIEW
Mars Air Curtains are
designed to cover door
openings, providing
both temperature
control/environmental
separation and flying
insect control when the
building’s doors are
opened. Typical
installation heights are:
BD-14 Series
(Environmental Separation up 16’ and Flying Insect
Control 14’), BD-18 Series (Environmental
Separation up 20’ and Flying Insect Control 18’),
BD-22 Series (Environmental Separation up 24’
and Flying Insect Control 22’), BD-26 Series
(Environmental Separation up 28’ and Flying Insect
Control 26’) and BD-30 Series (Environmental
Separation up 32’ and Flying Insect Control 30’).
The units are typically overhead mounted
horizontally above the door opening. They can also
be vertically mounted alongside the opening.
Heated units must be mounted on the inside or the
protected side of the opening. The motors used in
the BD Series range from 5 HP to 30 HP (see
submittal for details).
All the BD Series come standard with an expanded
metal air intake grille(s). The BD Series can be
configured with Flat Bank or V-Bank Sections, as
options.
GENERAL SAFETY
INFORMATION
Use this product only in
the manner intended
by the manufacturer. If
you have any
questions, contact the
manufacturer. Only
qualified personnel
should install this
product. Installing
personnel should have
a clear understanding
of these instructions
and should be aware of general safety precautions.
Improper installation can result in electric shock,
possible injury due to coming in contact with
moving parts, as well as other potential hazards.
WARNING
When servicing the product, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.
WARNING
To reduce the risk of fire, electric shock, or injury to
persons, observe the following.
A. Always disconnect, lock and tag power source before
installing or servicing product.
B. Installation work or electrical wiring must be done by
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated
construction.
C. The combustion airflow needed for safe operation of
fuel burning equipment in the area may be affected
by the product’s operation. Follow
the heating
equipment manufacturer’s guideline and safety
standards, such as those published by the National
Fire Protection Agency (NFPA), the American
Society of Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE) and local code authorities.
D.
When cutting or drilling into a wall or ceiling, be
careful not to damage electrical wiring and other
hidden utilities.

RECEIVING AND INSPECTION
Upon receiving the product, check to make sure all
items are accounted for by referencing the Bill of
Lading to ensure all items were received. Inspect
each carton for shipping damage before accepting
delivery. Notify the freight carrier if any damage is
noticed. The carrier will make notification on the
delivery receipt acknowledging any damage to the
product. All damage should be noted on all copies of
the Bill of Lading which is countersigned by the
delivering carrier. A Carrier Inspection Report
should be filled out by the carrier upon arrival
damaged upon arrival, file a claim immediately with
the carrier. Any physical damage to the unit after
acceptance is not the responsibility of Mars Air
Systems.
UNPACKING
Verify that all parts, components and accessories,
and the correct quantities of each have been
received. If any items are missing, report shortages
to Mars Air Systems directly to arrange for obtaining
the missing items. Again, verify quantities received
against those on the Bill of Lading only, as multiple
shipments may be involved.
INSTALLATION
Typical Mounting – Wall or Ceiling Mounted
Horizontally Above the Door Opening
1. Overhead installation is recommended to
prevent the possibility of the unit falling if the wall
to which the unit is mounted is hit by a truck or
material handling device. If, however, wall or
bracket mounting is preferred, additional holes
may be drilled in the side panels of the housing.
Note: Bracket/Support mounting is not generally
recommended for Air Curtains equipped with
steam or hot water coils. Overhead installation
using threaded rods with independent
suspension of coils is recommended.
2. Center the unit over the opening. The air curtain
shall be equal to or greater than the width of the
opening.
3. Four pre-punched 1/2” mounting holes on the top
of the unit are provided for your convenience.
These holes must be utilized to secure the
product overhead. All hardware is field provided
by others.
4. Mount the product such that the discharge is 1”
above the opening and all obstacles. (FIG. 1)
Note: If the product is installed higher than the
recommended 1” above the opening, then it
must be moved 3/8” away from the wall for every
1” that it is moved up. Any void between the wall
and the product must be sealed, by others, to
optimize performance.
FIG. 1
5. Use four (4) threaded rods for overhead
installation or four (4) threaded bolts for wall
installation. All hardware is field provided by
others. (FIG. 1)
6. If applicable, for tandem installation or products
mounted side by side, allow no more than 6”
between the two products. For overhead
installation using threaded rods, the products
may require a beam, by others, to span the full
distance of the mounting length. (Reference
Accessory Installation Supplement)
7. All wires must be connected to the external
junction box(s) of the unit.
8. The unit must be wired per NEC and local codes.
Electrical Field Wiring
The unit and any optional accessories must be wired
with the proper voltage to the junction box per the
wiring diagram. (FIG. 2, unheated products only)
WARNING
Precaution should be taken in explosive atmospheres.

FIG. 2
START-UP
This product has been assembled and tested at the
factory prior to shipping. The following procedures
should be performed to assure its performance. Before
continuing with the start-up, it is important to recognize
the safety controls furnished with the unit.
NOTE
For accessory installation, reference Accessory
Installation Supplement.
For heated products, reference Heated Products
Supplement.
WARNING
Prevent hazard of electrical shock. More than one
disconnect switch may be required to de-energize this
product.
WARNING
The following items must all be completed by a qualified
installer and checked off when completed
A. Re-
check that the product has been installed
properly and is level and secure.
B. Check all terminal screws are tight and field wiring
is connected in accordance to National Electrical
Code and wired per the enclosed wiring diagram.
For electric heated models, ensure that the coils
are secured and not touching each other on any
metal surface.
C. Verify proper voltage prior to powering the product.
(See product label for reference).
D. Check all field wired components “if supplied” are
wired correctly.
E. Check that the inlet air supply and the discharge air
supply are free of obstructions.
F. Check that all air filter(s) and/or air intake grille(s) are
in place and installed properly, as originally shipped.
G.
Verify voltage to the product once more and turn
power on.
H. Regardless of whether the product is mounted on the
inside or outs
ide of the door opening, set the air
directional vanes in the discharge nozzle slightly
outward to approximately 10-15° towards the outside,
or the wind load. (FIG. 3).
I. For products with control panels, turn the HOA (Hand-
On-Auto) selector switch to “On” position and open the
door to energize the product. For products without a
control panel or an On/Off switch, open the door to
energize the product.
J. If heated products are installed, reference Heated
Products Supplement.
K. For three phase units, verify direction of rotation of
blower wheels (note direction arrows on the blower
wheel housing). Correct if needed by changing
polarity of three phase power.
L. VERY IMPORTANT Using a clamp meter, measure
the amperage to each motor and ensure that they do
not exceed the amperage listed on the product label.
M. If applicable, adjust the air intake grille(s) such that the
output air stream reaches the floor. For temperature
control and environmental separation applications, the
air stream should reach the floor with sufficient
strength to create an air seal around the door opening
without creating turbulent mixing of the inside and
outside air. For flying insect control applications, the
air stream should reach the floor with maximum
strength. If after proper installation and adjustment,
the product appears to be producing too little or too
much air for the application, contact the manufacturer.
FIG. 3

MAINTENANCE
Routine maintenance is required to keep this product
operating at its peak performance and efficiency. Over
time, the housing, air intake grille, air intake filter,
blower wheels and motor(s) will accumulate a build up
of dust, debris and other residue. It is imperative to
keep these components clean. Failure to do so will not
only lower operational efficiency and performance, but
also reduce the useful life of the product. The time
between cleanings depends on the application,
location and daily hours of use. On average, under
normal use conditions, the product should require a
thorough cleaning once every six (6) months.
To clean the product, perform the following:
1. Verify the product has been disconnected from the
power source.
2. Use a damp cloth and either a warm mild soapy water
solution or bio-degradable degreaser, to wipe down
the exterior components of the housing.
3. To access the interior of the product, remove the air
intake grille(s) and/or air intake filter(s). This is
accomplished by removing the screws on the face of
the air intake grille(s)/filter(s) or top access panels.
4. Thoroughly clean the air intake grille(s)/filter(s) or top
access panels.
5. Thoroughly wipe down the motor, blower wheels and
blower wheel housings. Be careful not to spray the
motor with a water hose.
6. The motor(s) may require additional lubrication. The
cartridge bearings for blowers are permanently
lubricated double sealed ball bearings and do not
require additional lubrication. The pillow block
bearings require periodic greasing depending on use.
The Zerk fittings are provided on bearing.
7. To re-install the product, reverse the procedures
above.
8. Reconnect the power source to the product.
9. If you have any questions regarding the maintenance
of the product, contact the manufacturer.
SPECIAL APPLICATIONS
Outdoor Installation
For outdoor unit special consideration may be required
for enclosure, motor, wheel, and other components to
minimize damage caused by exposure to the outdoor
elements. Contact factory for special construction and
costing.
Freezer and Cooler Installation
Air curtain must be mounted on the warm side for
optimal performance. Variable Frequency Drive (VFD)
is strongly recommended to control the air curtain air
flow velocity at the floor level.
High humid areas may require de-humidifier or
additional defrost cycle to minimize condensation and
freezing for freezer applications. We recommend the air
curtain unit to not replace doors but work in conjunction
with door opening sequence cycle. Contact factory for
details.
DISCLAIMER
Mars reserves the right to change specifications and
product design without notice. Such revisions do not
entitle the buyer to corresponding changes,
improvements, additions, or replacements for
previously purchased equipment.
WARNING
To reduce the risk of fire, electrical shock or injury to
persons, observe the following:
A. Maintenance is to be performed only by qualified
personnel who are familiar with local codes and
regulations and are experienced with this type of
product.
B. Before servicing or cleaning the product switch
power off at service panel and lock service panel to
prevent power from being switched “ON”
accidentally.

TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
NO AIR BLOWING
OUT OF DISCHARGE
NOZZLE
- No power being supplied to the unit
from the electrical power source - Confirm power source / check if in on position
- Circuit breaker is tripped
- Reset circuit breaker
- Blown fuses on power supply
- Replace fuses
- Motor overload is open or tripped
- Allow the motor to cool down; motor has auto reset
internal overload; if unit is panel equipped, press
reset button on overload inside panel, or replace
motor overload if overload remains tripped
- Motor contactor / relay defective
(if applicable)
- Check voltage to coil; check contacts to see if they
are pulling in
- Failed switch
- Replace or repair limit switch
MOTOR IS RUNNING
BUT FANS ARE NOT
SPINNING
- Loose or broken coupling (belt drive) - Replace or tighten coupling
- Loose set screws on wheel hubs
- Tighten set screws on motor shaft flats
- Fan spinning inside fan housing
- Tighten fan on shaft or replace fan
- Broken fan hub
- Replace fan wheels
ELECTRICAL
CONTROLS NOT
WORKING WHEN
DOOR IS OPEN
- Switch is in off position - Turn unit's switch to the on position
- Door limit switch is not operating
- Repair or replace door limit switch
UNIT WILL NOT TURN
OFF
- Door limit switch is permanently
closed or energized
- Position the door switch in a manner that turns off the
unit when the door closes and turns on the unit when
the door opens. Only light pressure required.
LOW AIR FLOW
- Discharge air vanes out of
adjustment
- Adjust vanes to proper position
(Refer to Start-Up Section in this manual)
- Obstruction on intake or discharge
- Remove obstruction or move air curtain
-
Power leads out of polarity
- Switch power leads to correct polarity
(3 phase models only)
- Blower motor rotating below normal
speed
- Apply proper voltage per unit requirement
(see unit label) / Adjust adjustable motor speed knob
(if applicable)
- Fan rubbing against housing
- Free fan from housing
- Blower wheels clogged with dirt
- Clean and remove dirt from blower wheels
EXCESSIVE AIR
VELOCITY AT DOOR
OPENING
- Nozzle out of adjustment and not
angled far out enough (BD only) - Adjust nozzle angle to outside
- Air temperature too cold
- Add auxiliary heat to overcome wind chill
- Air stream pushing air outside of the
building
- Adjust discharge angle back into building
AIR NOT HITTING
THE FLOOR
- Low air velocity
- Adjust vanes to proper position or check installation
height (Refer to Start-Up Section in this manual)
- Obstruction in the direction of air flow
- Remove obstruction or move air curtain
(Move out 3/8" for every 1" up from the door)
- Negative building pressure
- Provide a make-up air system to relieve negative
building pressure
UNEVEN AIR
- Shaft rotating inside fan
- Replace fan or tighten fan on shaft
- One motor not functioning
- Replace or repair motor
EXCESSIVE NOISE
AND OR VIBRATION
- Loose or broken coupling (belt drive) - Replace or tighten coupling
- Loose set screws on wheel hubs
- Tighten set screws on motor shaft flats
- Fan spinning inside fan housing
- Tighten fan on shaft or replace fan
- Broken fan hub
- Replace fan wheels
- Bearing end caps worn
- Replace Bearing end caps
- Damaged blower wheel
- Replace Blower Wheel
- Bearing end caps worn
- Pillow block bearings make noise
- Replace Bearing end caps
- Grease Bearing
- Balancing clips missing
- Replace Blower Wheel

TROUBLESHOOTING MOTOR
To determine if the motor is in good operating condition, compare measured motor resistance at the motor
terminals to the values shown below.
HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450)
Applicable
Air Curtain
Series
Mars Part # Manufacturer Part # Brand Motor Rating HP Voltage Phase
Black Motor Wire & White
Motor Wire
--
03-001 7190-1682 Fasco Nema 1 1/6 115 111.5 - -
03-002 7190-1903 Fasco Nema 1 1/6 115 18.4 - -
03-003 7190-1825 Fasco Nema 1 1/6 230 164 - -
03-004 7190-1904 Fasco Nema 1 1/6 230 144.6 - -
Applicable
Air Curtain
Series
Mars Part # Manufacturer Part # Brand Motor Rating HP Voltage Phase
White Motor Wire (T1)
&
Black Motor Wire (T3)
White Motor Wire (T1)
&
Black Motor Wire (T5)
White Motor Wire (T1)
&
Black Motor Wire (T2)
03-010 34G928X169 Baldor Washdown (IP54) 1/2 115 11.2 - -
03-010 34G928X169 Baldor Washdown (IP54) 1/2 208/230 14.6 - -
03-005 7124-1175 Genteq Nema 1 1/2 115 12.6 3.8 5.2
03-006 7124-1560 Genteq Nema 1 1/2 208/230 19.9 15.9 22.5
03-007 48S17T439 Marathon Nema 1 1/2 277 17.7 - -
03-005 K055PWM1736C13H Nidec Nema 1 1/2 115 12.1 3.7 5.2
03-005 K055PWM1736C13H US Nema 1 1/2 115 15.3 3.7 5.4
03-006 US Nema 1 1/2 208/230 18.7 18.2 24.2
Applicable
Air Curtain
Series
Mars Part # Manufacturer Part # Brand Motor Rating HP Voltage Phase
White Motor Wire (T1)
&
Black Motor Wire (T2)
White Motor Wire (T1)
&
Black Motor Wire (T3)
-
03-021 35T276R025G1 Baldor Washdown (IP54) 1115 10.7 - -
03-015-Baldor 35M316S174 Baldor Nema 1 1115 10.6 - -
03-015-Baldor 35M316S174 Baldor Nema 1 1208/230 12.2 - -
03-021 35T276R025G1 Baldor Washdown (IP54) 1208/230 12.8 - -
03-014 7124-0985 Genteq Nema 1 1115 11.6 2.4 -
03-015 7124-1096 Genteq Nema 1 1208/230 16.5 9.2 -
03-015 -Nidec Nema 1 1208/230 14.3 6.5 -
03-014 K55BWJZB-2362 US Nema 1 1115 1 1 2.1 -
03-015 -US Nema 1 1208/230 13.2 6.3 -
Black Motor Wire (L1)
&
Red Motor Wire (L2)
Black Motor Wire (L1)
&
White Motor Wire (L3)
Red Motor Wire (L2)
&
White Motor Wire (L3)
03-008 P55YYDHB-1527 US Nema 1 1/2 208-230 316.1 16.1 16.1
03-008 P55YYDHB-1527 US Nema 1 1/2 460 363.6 63.6 63.6
03-009 48T17T135 Marathon Nema 1 1/2 575 3136 136 136
03-017 56T17T5541 Marathon Nema 1 1208-230 34.3 4.3 4.3
03-017 56T17T5541 Marathon Nema 1 1460 316.5 16.5 16.5
03-018 56T17T5544 Marathon Nema 1 1575 326.6 26.6 26.6
03-022 35N127S902 Baldor Washdown (IP54) 1208-230 35.1 5.1 5.1
03-022 35N127S902 Baldor Washdown (IP54) 1460 319.8 19.8 19.8
03-026 165716 Century Nema 1 3208-230 31.5 1.5 1.5
03-026 165716 Century Nema 1 3460 35.7 5.7 5.7
03-028 35E92Y26 Baldor Nema 1 3575 39.2 9.2 9.2
03-110 36H110-2211G1 Baldor Nema 1 1,2,3 208-230 33.5 3.5 3.5
03-110 36H110-2211G1 Baldor Nema 1 1,2,3 460 313.5 13.5 13.5
03-055 37F932W828G1 Baldor Nema 1 5230 30.7 0.7 0.7
03-055 37F932W828G1 Baldor Nema 1 5460 32.4 2.4 2.4
03-046 37F909X889G1 Baldor Nema 1 7230 30.6 0.6 0.6
03-046 37F909X889G1 Baldor Nema 1 7460 31.6 1.6 1.6
03-033 U639A - 215TTFC6027 Marathon Nema 1 10 208-230 30.4 0.4 0.4
03-033 U639A - 215TTFC6027 Marathon Nema 1 10 460 31.2 1.2 1.2
03-074 GT1128A 170118.60 Marathon Nema 1 25 575 30.5 0.5 0.5
BD
HV2, NH2,
PH12
EP2
WMI
WMH
STD2, N2,
PH10, QP10
Applicable
Air Curtain
Series
Mars Part #
HP
Voltage
Brand
Motor Rating
Manufacturer Part #
Phase
LEAD WIRE OHM READINGS
MOTOR WIRES OR TERMINAL (T) OHM READINGS
Single Phase Motors
MARS MOTOR RESISTANCE READINGS
Three Phase Motors
LPV2, LPN2
STD2, N2,
PH10, QP10
HV2, NH2,
PH12

WARRANTY
Mars’ warranty coverage, period, extent, and
limitations apply to the product only. It does not apply
to labor. Mars warrants that the Mars product 1) is
free from defects in materials and workmanship, and
2) conforms to Mars’ published specifications. The
warranty period for Mars products (except for heated
models, custom models, or WMI, WMH and BD
models) is a five (5) year period commencing on the
date of shipment. The warranty for heated models is
an eighteen (18) month period, the warranty for
custom models and for accessories is a twelve (12)
month period, and the warranty for WMI, WMH, and
BD models is a twelve (12) month period. The date
on the customer’s invoice is the date of shipment
unless Mars or your reseller informs you and Mars
otherwise. Mars will provide free replacement of any
part that fails as a result of a defect in material or
manufacturer’s workmanship. Changes in
operational specification parameters that differ from
those provided on the original purchase order are not
covered. Mars products are inspected and tested
before packaging and are shipped in working
condition. The warranty for Mars products only
covers free-of-charge replacement of failed parts.
The warranty does not cover labor and transportation
expenses that may be required to deliver and to
install replacement parts. Because in many
instances it is impossible to determine the cause of
failure, the customer may be responsible for
transportation charges associated with replacement
of failed part. Mars does not warrant uninterrupted or
error-free operation of Mars product. Under no
circumstance is Mars liable for any of the following:
1) third-party claims against you for damages, 2)
special, incidental, or indirect damages, or 3) any
economic consequential damages (including lost
profits and savings), regardless of whether Mars, its
suppliers, or its resellers were informed of the
possibility of damages. The warranty does not cover
repair or exchange of Mars products resulting from
misuse, accidental damage, modification, unsuitable
physical or operating environment, improper
maintenance or installation by customer, or failure
caused by a product for which Mars is not
responsible. The warranty does not cover damages
caused by mishandling during transportation. The
warranty is voided by removal or alteration of Mars
product or parts identification labels, and by improper
installation of product and resulting non-compliance
with federal, state, and local codes and regulations.
Additionally, Mars reserves the right to void the
warranty for non-payment of invoice.
CONTACT FACTORY FOR COMPLETE PARTS
LIST FOR ALL MODELS.
KEEP THIS MANUAL FOR YOUR RECORDS.
Model Number:______________________________
Serial Number: ______________________________
Date Purchased: ____________________________
Dealer Purchased From: ______________________
14716 S. Broadway St., Gardena, CA 90248
(310) 532–1555 ● (800) 421-1266
Fax: (310) 324-3030
Please go to our website at www.marsair.com for a
downloadable version of this document.

Mars WindGuard BD22-CSI-Spec Revised 2/3/2021
MARS AIR SYSTEMS, LLC
23 34 33 – 1
SECTION 23 34 33
AIR CURTAINS
Important Note: This specification contains hidden text appearing in red. To show or remove hidden text
in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select
“Display,” and check or uncheck the box marked “Hidden Text.”
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Air curtains for pedestrian entrances.
B. Air curtains for vehicular entrances.
C. Air curtains for large loading dock doors.
1.2 RELATED SECTIONS
A. Section 05 50 00 – Metal Fabrications: Concealed steel support members.
B. Section 06 10 00 – Rough Carpentry.
C. Section 05 41 00 – Structural Metal Studs.
D. Section 07 62 00 – Sheet metal flashing.
E. Section 07 92 00 – Joint Sealants.
F. Section 08 10 00 – Metal Doors and Frames.
G. Section 08 33 00 – Overhead Coiling Doors.
H. Section 08 42 00 – Entrance Doors.
I. Section 22 10 00 – Plumbing Piping:
J. Section 23 21 00 – Hydronic Piping: Hot water heating piping to units.

Mars WindGuard BD22-CSI-Spec Revised 2/3/2021
MARS AIR SYSTEMS, LLC
23 34 33 – 2
K. Section 23 22 13- Steam and Condensate Piping: Steam heating piping to units.
L. Section 26 05 00 – Equipment Wiring: Connections to building power distribution.
1.3 REFERENCES
A. ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium.
B. ASTM A591 / A591M -98 – Standard Specification for Steel Sheet, Electrolytic Zinc-
Coated, for Light Coating Weight (Mass) Application (Withdrawn in 2005, replaced by
A879/A879M).
C. ASTM A879 / A879M -06 – Standard Specification for Steel Sheet, Zinc Coated by the
Electrolytic Process for Application Requiring Designation of the Coating Mass on Each
Surface.
D. ASTM A653 / A653M -09a – Standard Specification for Steel Sheet, Zinc Coated
(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
E. AHRI 410-2001 – Standard for Forced-Circulation Air-cooling and Air-Heating Coils.
F. CRN – Canadian Registration Number Coil.
G. ANSI Z223-NFPA 54 – National Fuel Gas Code/
H. NEC – National Electric Code.
I. U.S. Green Building Council, LEED Building Design and Construction (BD+C) Version
4.0 Rating System. (LEED v4.0)
1.4 SUBMITTALS
A. Submit under provisions of Section 01 33 00.
B. Product Data: Manufacturer's data sheets on each product to be used, including:
1. Preparation instructions and recommendations.
2. Storage and handling requirements and recommendations.
3. Installation methods.
C. Shop Drawings: Include plans, elevations, sections, and details, indicating dimensions,
tolerances, materials, fasteners, hardware, finish, piping, electrical wiring diagrams,
options, and accessories.
D. LEED Submittals: Provide documentation of how the requirements of Credit will be met:
1. List of proposed materials with recycled content. Indicate post-consumer
recycled content and pre-consumer recycled content for each product having
recycled content.

Mars WindGuard BD22-CSI-Spec Revised 2/3/2021
MARS AIR SYSTEMS, LLC
23 34 33 – 3
2. Product data and certification letter indicating percentages by weight of post-
consumer and pre-consumer recycled content for products having recycled
content.
E. Selection Samples: For each finish product specified, two complete sets of color chips
representing manufacturer's full range of available colors and patterns.
F. Verification Samples: For each finish product specified, two samples, minimum size 6.25
inches (160 mm) square, representing actual product, color, and patterns.
G. Manufacturer's Certificates: Certify products meet or exceed specified requirements.
H. Operation and Maintenance Manual: Submit manufacturer's operation and maintenance
manual, including operation, maintenance, adjustment, and cleaning instructions,
troubleshooting guide, parts list, and electrical wiring diagrams.
1.5 QUALITY ASSURANCE
A. Manufacturer Qualifications: Minimum ten years documented experience producing the
products specified in this Section
B. Installer Qualifications: Minimum five years documented experience installing products
specified in this Section
1.6 DELIVERY, STORAGE, AND HANDLING
A. Store products in manufacturer's unopened packaging until ready for installation.
B. Store in a dry, heated storage area until installation of products.
C. Protect materials and finish from damage during handling and installation.
1.7 SEQUENCING
A. Ensure that locating templates and other information required for installation of products
of this section are furnished to affected trades in time to prevent interruption of
construction progress.
B. Coordinate the installation of wiring and control switches for air curtains with the
openings and the hardware provided for such openings.
C. Install after doors, walls, ceilings, and other adjacent surfaces are finished and painted.
1.8 WARRANTY
A. Standard one-year limited parts warranty for unheated units against defects in
workmanship and material.

Mars WindGuard BD22-CSI-Spec Revised 2/3/2021
MARS AIR SYSTEMS, LLC
23 34 33 – 4
B. Standard one-year limited parts warranty for heated units against defects in workmanship
and materials.
PART 2 PRODUCTS
2.1 MANUFACTURER
A. Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena,
CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email:
info@marsair.com. Web: www.marsair.com.
B. Delete one of the following two paragraphs: coordinate with requirements of Division 1
section on product options and substitutions.
C. Requests for substitutions will be considered in accordance with provisions of Section 01
33 00.
2.2 AIR CURTAIN ASSEMBLIES
A. Motor Fan Assembly: Design for easy removal, assembly, repair, and maintenance.
1. Motor: Totally enclosed fan cooled (TEFC) motor with sealed lifetime pre-
lubricated ball bearings.
a. Wired for single speed operation, but inverter rated.
b. Provide wash down type motors, NEC IP-54 for the locations indicated.
c. Provide explosion proof type motors, NEC Class 1, Division 1, Group D
for the locations indicated.
a. Electrical Characteristics: 208/230V AC, three-phase; 28.0/26.0 Amp
full load per motor/fan for units up to 96 inches wide.
b. Electrical Characteristics: 208/230V AC, three-phase; 42.0/40.0 Amp
full load per motor for units 120 inches to 144 inches wide.
c. Electrical Characteristics: 208/230V AC, three-phase; 55.0/55.0 Amp
full load per motor for units 168 inches to 192 inches wide.
d. Electrical Characteristics: 460V AC, three-phase; 14 Amp full load per
motor/fan for units up to 96 inches wide.
e. Electrical Characteristics: 460V AC, three-phase; 20.0 Amp full load per
motor for units 120 inches to 144 inches wide.
f. Electrical Characteristics: 460V AC, three-phase; 25.0 Amp full load per
motor/fan for units 168 inches to 192 inches wide.
g. Electrical Characteristics: 575V AC, three-phase; 10.3 Amp full load per
motor/fan for units up to 96 inches wide.
h. Electrical Characteristics: 575V AC, three-phase; 15.6 Amp full load per
motor for units 120 inches to 144 inches wide.
2. Electrical Characteristics: 575V AC, three-phase; 20.2 Amp full load per
motor/fan for units 168 inches to 192 inches wide. Fans: Forward curved
centrifugal type, double width, and double inlet design, directly driven to an
electric motor.
a. Provide rigid mounted base between motor and frame.
b. Factory balanced blower wheel assembly statically and dynamically.

Mars WindGuard BD22-CSI-Spec Revised 2/3/2021
MARS AIR SYSTEMS, LLC
23 34 33 – 5
B. Housing: Self-contained one-piece type with sufficient strength for mounting from pre-
punched mounting holes at both ends to adjacent walls or ceiling without intermediate
support.
1. Size:
a. Unheated: 36 inches deep by 28 inches high by width of unit.
b. Electric Heated: 42 inches deep by 28 inches high by width of unit.
c. Hot Water/Steam Heated: Depth 42 inches single row and 44 inches
double row by 28 inches high by width of unit plus 10 inches for
manifolds.
d. Indirect Fired Gas Heated: 82 1/2 inches deep (including transition and
furnace) by 33 inches high by width of unit.
2. Mounting:
a. Unheated Inside Mount.
b. Heated Inside Mount.
c. Unheated Outside Mount.
d. Mount Location Indicated.
3. Material:
a. Provide 10-, 12-, and 14-gauge electro or hot dipped galvanized steel
sheet housing conforming to ASTM A 591 and/or ASTM A 653.
b. Provide type 304 stainless steel housing with brushed finish. ASTM A
240/A 240M.
4. Air Inlet Grille and/or Filters: Provide air inlet grille and/or filters specified.
5. Discharge: Provide integral discharge nozzle specified.
6. Finish and Color: Provide with, no VOC, corrosion resistant polyurethane
powder coated finish for sheet metal housings.
a. Titanium Silver.
b. Obsidian Black.
c. Pearl White.
d. Stainless Steel.
C. Environmental and Flying Insect Control Air Curtains: Models for Heights up to 24 feet
(7315 mm) for Environmental Separation and Temperature Control and up to 22 feet
(6706 mm) for Flying Insect Control.
1. Discharge Nozzle: Adjustable air foil vanes with a plus/minus 40-degree sweep
front to back.
2. Air Velocity at Nozzle:
a. BD 22 96-1: 107 Inch (2720 mm) Wide Units: 6000 feet/min (30.5 m/s)
single 10HP motor/fan assemblies.
b. BD 22 120-1: 131 Inch (3329 mm) Wide Units: 6000 feet/min (30.5 m/s)
single 15HP motor/fan assemblies.
c. BD 22 144-1: 155 Inch (3939 mm) Wide Units: 6000 feet/min (30.5 m/s)
single 15HP motor/fan assemblies.
d. BD 22 168-1: 179 Inch (4549 mm) Wide Units: 6000 feet/min (30.5 m/s)
single 20HP motor/fan assemblies.
e. BD 22 192-1: 203 Inch (5159 mm) Wide Units: 6000 feet/min (30.5 m/s)
single 20HP motor/fan assemblies.
3. Air Speed at Floor: Minimum of 400 fpm (2m/s) at 3 feet (914 mm) from the
floor.

Mars WindGuard BD22-CSI-Spec Revised 2/3/2021
MARS AIR SYSTEMS, LLC
23 34 33 – 6
4. Air Inlet Grille and Filters:
a. Location: Front.
b. Type: Fixed air intake grille.
1) Expanded Metal: 85% open area.
c. Type: Filter Only as follows:
1) Filter: Flat bank 2-inch, disposable.
2) Filter: V-bank 2-inch disposable.
3) Filter: V-bank 2-inch aluminum washable.
5. Sound Pressure Level At 10 feet (3 m) From Nozzle:
a. Single Motor/Fan, 10HP Units: 75 dBA.
b. Single Motor/Fan, 15HP Units: 76 dBA.
c. Single Motor/Fan, 20HP Units: 77 dBA.
2.3 COMPONENTS
A. Electric Heaters: Provide complete with motor control panel factory mounted to air
curtain housing, and thermostat to be field installed.
1. Temperature limit controller.
2. Thermostat: Wall-mounted, 24-Volt operation, with heater on/off selection.
3. Heating Coils: UL approved. Factory mounted on the intake side of the air
curtain.
B. Steam Heaters: Provide finned tube steam coils for field mounting on air intake side of
the air curtain cabinet with opposite end connections.
1. Output: Air curtain manufacturer's standard, one-row coils.
2. Output: Air curtain manufacturer's standard, two-row coils.
3. Coils: Certified in accordance with AHRI 410.
4. Connections: Opposite end, horizontal.
5. Connections: Same end, right hand, horizontal.
6. Connections: Same end, left hand, horizontal.
7. Connections: Opposite end, vertical.
8. Connections: Same end, right hand, vertical.
9. Connections: Same end, left hand, vertical.
10. Casing: One-piece unpainted galvanized steel, bolted to air curtain housing.
C. Hot Water Heaters: Provide finned tube water coils for field mounting on air intake side
of the air curtain cabinet with opposite end connections.
1. Output: Air curtain manufacturer's standard, one-row coils.
2. Output: Air curtain manufacturer's standard, two-row coils.
3. Coils: Certified in accordance with AHRI 410.
4. Connections: Opposite end, horizontal.
5. Connections: Same end, right hand, horizontal.
6. Connections: Same end, left hand, horizontal.
7. Connections: Opposite end, vertical.
8. Connections: Same end, right hand, vertical.
9. Connections: Same end, left hand, vertical.
10. Casing: One-piece unpainted galvanized steel, bolted to air curtain housing.
11. Supply and return fittings on top of casing.
This manual suits for next models
5
Table of contents
Other Mars Air Systems Heater manuals
Popular Heater manuals by other brands

Toyostove
Toyostove LR-450 Type D Operation and maintenance instructions

HOM
HOM Xilo L Installation instruction

EUROM
EUROM 352160 instruction manual

ahlsell
ahlsell aLight Office LED Tec instruction manual

Greenlee
Greenlee 849 Operation, service and parts instruction manual

Juliana
Juliana F04453 Assembly instruction