Martin-Till SmartClean User manual

Martin Industries LLC
206 Elk Fork Road
Elkton, KY 42220
Telephone: 270-265-5817
E-Mail: martin@martintill.com
www.martintill.com VERSION 05-02-19
Installation Instructions

1
LIST OF CONTENTS:
Components introduction
1.1. Standard components
1.2. Optional components
2. Air cylinders installation
2.1. SmartClean bracket sets for different bundles
2.2. Top brackets installed on row cleaner mounts
2.3. Bottom brackets installed on row cleaner Frames
3. Plumbing box
3.1 Plumbing box overview
3.2 Plumbing box installation
4. Tubing
4.1 From plumbing box to air cylinders
4.2 Inside the pluming box ( Standard factory plumbing)
4.3 Plumbing box retubing for Bi-Directional Control
5. Wiring
6. Smart Clean app
6.1 Download the App
6.2 Connect to your Martin-Till SmartClean
6.3 Configure your Martin-Till SmartClean
6.4 Single Valve Bank ( No Air Bag)
6.5 Single Valve Bank ( Air Bag)
6.6 Bi-directional Control
6.7 Dual Valve Bank
7. Troubleshooting
Appendix :
Base Plate Drilling Template

2
1. COMPONENTS INTRODUCTION
1.1. Standard components
The following standard components are included in your Smart Clean purchase:
1. Plumbing box (SC-ASSEMBLY-1)
2. Air preparation filter/regulator (SC-FILTER)
3. Signal converter box (JCA00-015001)
4. ORIOLE controller box (JCA00-009001)
5. Planter harness (JCA86-000012)
6. Power harness (JCA86-000011)
1.2. Optional components
The following optional components to be ordered separately:
1. Air Cylinders (SC-CYL-2x2)
2. Double valve plumbing box (With additional airbag valve)(SC-ASSEMBLY-2)
3. Top and bottom cylinder brackets (Specific to your order)
4. Hardware kit
5. Pneumatic lines and fitting kits
6. VIair heavy duty Compressor (SC-AC-12V )
7. Compressor harness
2. CYLINDER INSTALLATION
The stationary end of the cylinder connects to the row cleaner’s mount (or the planter in some
cases) using top brackets and the moving end of the cylinder connects to the row cleaner’s
frame using the bottom brackets. Top brackets are specific to the row cleaner’s mount model
and bottom brackets are specific to the row cleaner’s frame model .
Cylinder’s top air inlet
The moving end connects to the row
cleaner frame using 3/8 ” Pin
The stationary end connects
to the mount using 7/16” Pin
Cylinder’s bottom air inlet

3
2.1. Smartclean bracket sets for different bundles:
SC-BD1360SC-BD1345SC-BKW1360
SC-BKW1345
SC-1360-UMOR
SC-1360-UMOLSC-1345-UMOL SC-1345-UMOR
SC-BDC1360

Right UMO-100 and Left SmartClean
Cylinder top bracket set are shown
SmartClean Bracket Set (SC-CUB-2L)
3/8” X 1 1/4” FLANGE BOLTS (B5F38NC114)
3/8” FLANGE NUTS (N38CFL)
SmartClean BOTTOM BRACKETS ( SC-1345-FR-MT)
2.2. Top bracket installation on row cleaner mount:
The top brackets are installed directly on the mount using the same hole patterns as the row
cleaner mount ( Left Picture). The UMO top brackets are designed for all single or dual UMO at-
tachments , and are installed as shown in the right picture. They come in right and left sets and
are used with their opposite side UMO.
2.3. Bottom bracket installation on row cleaner Frame:
• WA1345 Frame:
4

5/16” NUT
(N516CH)
5/16” x 1 1/4” BOLT AND FLAT
WASHER(B5m516NC114 &W516)
5/8” BUSHING
(SC-FR-SPACER)
5/16” NUT &
FLAT WASHER
(N516 &W516)
5/8” x 1 3/4” FLANGE
PATCH BOLT
(B5F58NC134)
5/16” x 1/2” BOLT
(B5m516NC12)
Smartclean Anchor
(SC-1360FR-MT-R)
IMPORTANT NOTE:
It is very important to limit the row cleaner down travel by adjusting the cam ad-
juster or the stop bolt to prevent the air cylinder from extending or retracting ful-
ly by setting stop bolt or cam to catch the row cleaner just before the cylinder
reaches the end of its stroke. Failure to do so will destroy the cylinder prema-
turely.
• WA1360 frame:
Install the bottom bracket as shown in the picture.
• Use 5/8” x 1 3/4” bolt
• Use 5/16” x 1 1/4 ” bolt, 5/16” flat washer , 5/8” bushing & 5/16” nut (N516CH)
5
If installing the wheel in rear hole, use 5/16” x 1 1/4 ” bolt, two 5/16” flat washers, 5/8” bush-
ing and 5/16” nut (N516CH) in front hole as shown in the below picture to prevent bottom
anchor from rotating and use 5/16” x 1/2” bolt and 5/16” nut (N516CH) in the top hole of the D
-LOCK DEFLECTOR .
5/16” x 1 1/4” BOLT AND FLAT
WASHER (B5m516NC114 &W516)
5/16” NUT and
Washer(N516
&W516)
5/8” x 1 3/4” FLANGE
PATCH BOLT
(B5F58NC134)
5/8” BUSHING
(SC-FR-SPACER)
Smartclean Anchor
(SC-1360FR-MT -R)

3. PLUMBING BOX
3.1 Plumbing box overview
The plumbing box (SC-ASSEMBLY-1) connects wirelessly to your smart phone and allows you to
control the row cleaner’s downforce by controlling the cylinder’s air pressure . The control box
includes one pressure regulator valve (SC-QB1), one directional valve (SC-DIR-VALVE), signal
converter box (JCA00-015001), ORIOLE controller box (JCA00-009001)), and an external air
filter/regulator (SC-FILTER). The plumbing box (SC-ASSEMBLY-2) includes an extra pressure
regulator valve (SC-QB1).
3.2 Plumbing box installation
Since the plumbing box is connected to your smartphone wirelessly , it doesn’t have to be in-
stalled inside the cab. However, for better Bluetooth connectivity, It is recommended to install
it within the line of sight of the cab in a central location. Open the plumbing box cover loosen-
ing the 3/8” locknuts on the top of the box and use the 3/8” holes under the box to attach and
secure the plumbing box on the planter. Use the template on page 20 for possible mounting
hole locations.
(Air Bag control option )
“Up” air outlet
“Down” air outlet
Air inlet
Planter cable inlet
6
4. TUBING
4.1 From plumbing box to air cylinders
According to the picture, connect the box’s “Up” air outlet to the bottom air inlets of the cylin-
ders using the 1/4” tubing and tee fittings provided.
Smart Clean Assembly 1 single valve up/down/oat
conguraon
See addendum for other conguraons/Opons

•
Use different colored tubing for the up and down circuits. Connect
the box’s “Down” air out-
let to either the extend or retract end of the cylinder and use the other color for the opposite
end.
Filtered dirt container
Pressure adjustment knob
Pressure gage
7
• Connect the air preparation filter/regulator’s outlet port to the air inlet of the control box us-
ing the provided black 1/4” tubing.
• Turn on the air supply, then lift up the top knob on the filter/regulator and rotate it to adjust
the air pressure shown on the gage to 120 PSI max.
• If your planter is equipped with airbags and you ordered the double valve plumbing box with
additional airbag valve(SC-ASSEMBLY-2), connect the box’s “Airbag” outlet to the airbags
circuit using the 1/4” tubing and tee fittings provided.
• Use the provided zip ties to secure the tubes.
• Make sure that the tubes will not be stretched or sharply bent during planter movement or
folding/unfolding. It is highly recommended to follow the possible existing wiring harnesses
or airbag tubing routes.
• To make tubing easier, you can start by connecting the very first air cylinder to the very last
air cylinder ( for both inlets) , then cut the tube at any conjunction and take branches for
middle air cylinders and plumbing box by adding Tee connections.
• Connect the air preparation filter/regulator (SC-FILTER) to your air supply. You can use your
own air compressor or buy the optional compressor (SC-AC-12). Look at the air flow arrow
shown on the filter/regulator and connect the air supply to the inlet port of the filter/
regulator.

4.2 Inside the pluming box ( Standard factory plumbing)
Although you may have received a complete box , the standard factory plumbing of the
valves inside the box is described here for future reference.
The standard plumbing box (SC-ASSEMBLY-1), includes one pressure regulator valve ( Bank-1)
and one Directional Valve, while the Double valve plumbing box (SC-ASSEMBLY-2) includes an
extra pressure regulator valve ( Bank-2). All the valves are shown in the picture.
There are four tubing routes as follows:
Route1 : Tubing from air inlet to pressure regulators and directional valve pilot inlets
Bank-1 pressure regulator
connector
Bank-2 pressure
regulator for plant-
ers equipped with
airbags or for Bi-
Directional Control
Bank-1 has a Tee connection fitting
when Bank-2 is available
Directional valve
Directional valve pilot air inlets
Bank-1 pressure regulator
Air inlet
Bank-2 pressure regulator
Air inlet
Route 1
Plumbing Box’s Air inlet
8

Route2 : Tubing from Bank-1 pressure regulator outlet to directional valves main inlet
Route 4 : Tubing from Bank-2 pressure regulator outlet to Airbag outlet
Route 3: Tubing from Directional valves outlets to Up and Down outlets
Bank-1 pressure regulator
outlet
Directional Valve main inlet
Route 2
Must include at least 2 loops
Directional Valve extraction outlet
Directional Valve retraction outlet
Plumbing Box’s Up Outlet
Plumbing Box’s Down Outlet
Plumbing Box’s Airbag Outlet
Bank-2 pressure regulator
outlet
9

10
Point 2: Down Outlet
Point 1: Up Outlet
Point 4: Directional valve Inlet
Point 3 : Airbag outlet
4.3 Plumbing box retubing for Bi-Directional Control
The bi-directional control configuration requires a 2-valve system (Part No: SC-ASSEMBLY-2).
The plumbing box valve connection needs to be reconfigured as described bellow for bi-
directional control.
Step 1: Disconnect the tube ends only at the points shown in the picture. Don’t disconnect the
other ends of the tubes.
Point 1: Up outlet
Point 2: Down outlet
Point 3: Airbag Outlet
Point 4: Directional valve inlet
Complete plumbed box is shown from left and right views in bellow pictures.
Check for any
leaks before closing the plumbing box cover.

Step 3 : Connect the Bank-2 pressure regulator outlet to the Down Outlet as shown in the pic-
ture.
Down Outlet
Bank-2 pressure regulator outlet
Step 4 : The retubing process is complete. You can leave the tubes with one open ends inside
the box. Plug the three open ends ( two hoses connected to the directional valve and direction-
al valve main inlet).
Follow the instruction in section 6.6 to test the Bi-Directional control configuration. Check for
any leaks before closing the plumbing box cover.
11
Step 2 : Connect the Bank-1 pressure regulator outlet to the Up Outlet as shown in the picture.
Bank-1 pressure regulator outlet
Up Outlet

12
5. WIRING:
Identify the two harnesses provided for the control box wiring:
•
Planters harness (JCA86-000012 ) with 9 connectors.
•
Power harness (JCA86-000011) with one connector and two ring wire-ends
Start with the planters harness.
• Locate the connector labeled “CONVERTER BOX” and connect it to the provided Signal con-
verter box (JCA00-015001) shown in the picture.
• Locate the connectors labeled “ORL-A” and “ORL-B” and connect them to the provided ORI-
OLE controller box (JCA00-009001) shown in the picture.
• Locate the connector labeled “PRES-REG BANK-1” and connect it to the bank-1 pressure
regulator in the box. The bank-1 pressure regulator is the one farther from the air inlet/
outlets and has a tee connection fitting. Secure the connector to the valve using the center
bolt provided in the small plastic bag attached to the planter harness .
Bank-1 pressure regulator
connector
Bank-2 pressure regulator
connector
Tee connection fitting

• Locate the connector labeled “EXT-VLV” and connect it to the extraction side of the direc-
tional valve as shown in the picture. Secure the connector to the valve using the center bolt
provided in the small plastic bag attached to the planter harness .
Continue with the power harness.
• Locate the connector labeled “POWER” and connect it to its mated connector on the planters
harness.
• Connect the two ring wire-ends (Labeled RT-1 and RT-2) of the power harness to 12 Volts
power supply on your tractor. Make sure that the red wire (RT-1) is connected to switch-on
positive and the black wire (RT-2) is connected to negative. Incorrect connecting of the
power wires can damage the electronics components.
• Close the box cover.
• Secure the harnesses, converter box, and ORIOLE controller box to the planter using the
provided zip ties.
Directional valve retraction
connector
Directional valve extraction
connector
Tee connection fitting
Directional valve
• If you ordered the double valve plumbing box with additional airbag valve(SC-ASSEMBLY-2),
locate the connector labeled “PRES-REG BANK-2” and connect it to the bank-2 pressure reg-
ulator in the box. The bank-2 pressure regulator is the one closer to the air inlets/outlets
and doesn’t have a tee connection fitting. Secure the connector to the valve using the center
bolt provided in the small plastic bag attached to the planter harness .
• Locate the connector labeled “RET-VLV” and connect it to retraction side of the directional
valve as shown in the picture. Secure the connector to the valve using the center bolt pro-
vided in the small plastic bag attached to the planter harness.
13

6. SMART CLEAN APP
The Martin-Till SmartClean system is controlled via an app that can be installed on iOS and An-
droid devices. The app controls the system over a wireless Bluetooth connection.
6.1 Download the App
Installing the Martin-Till Smart C lean V2 app on an iOS or Android mobile device is the first
step.
•
Go to the Google Play Store or the iOS App Store
•
Search for Martin-Till Smart Clean V2
•
Install the app titled Martin-Till Smart Clean V2
6.2 Connect to your Martin-Till SmartClean
Follow the below steps to connect to the Martin-Till SmartClean system.
15
1. Noce the Bluetooth:Not Connected
message. Click on the gear
2. Click on the Bluetooth label 3. If Bluetooth is disabled, ENABLE will
have black font. Click ENABLE

1. Click on the gear 2. Click on System Conguraon 3. Select the appropriate congura-
on 16
4. When Bluetooth is enabled, ENABLE
will have grey font and available de-
vices will be listed. Click SmartClean in
the list of Available Devices.
5. A vericaon prompt will be dis-
played. Click OK
6. Aer the device is successfully con-
nected, a green Connected To Control-
ler message will be displayed momen-
tarily and the SmartClean device will
be in the list of Connected Devices.
6.3 Configure your Martin-Till SmartClean
The Martin-Till SmartClean can have several different configurations. The operator must se-
lect the proper configuration within the app by launching the Smart Clean V2 app following
the instructions below.

6.4 Single Valve Bank (No Air Bag)
Not Connected State (Bluetooth:
Not Connected and UP/FLOAT/
DOWN buons are all blue)
Connected State
Select the direcon pressure is applied.
Select the target pressure applied by clicking
the up and down buons, or the actual num-
ber to manually enter a value.
Actual pressure value.
6.5 Single Valve Bank (Air Bag)
NOTE: To run this configuration the Part SC-Assembly-2 (2-Valves) must be installed
Not Connected State (Bluetooth:
Not Connected and UP/FLOAT/
DOWN buons are all blue)
Connected State
Select the direcon pressure is applied.
Actual pressure value.
Select the target pressure applied by clicking
the up and down buons, or the actual num-
ber to manually enter a value.
17

6.6 Bi-Directional Control
The bi-directional control configuration requires a 2 -valve system (Part No: SC-ASSEMBLY-2).
The plumbing box valve connection needs to be reconfigured for bi-directional control as was
described in section 4.3.
Not Connected State (Bluetooth:
Not Connected)
Connected State
Actual pressure value.
Select the target pressure applied by clicking
the up and down buons, or the actual num-
ber to manually enter a value.
6.7 Dual Valve Bank * Not Currently Supported *
The bi-directional control configuration requires a 2 -valve system (Part No: SC-ASSEMBLY-2),
and is not currently supported.
Not Connected State (Bluetooth:
Not Connected and UP/FLOAT/
DOWN buons are all blue)
Connected State
Select the direcon pressure is applied.
Actual pressure value.
Select the target pressure applied by clicking
the up and down buons, or the actual num-
ber to manually enter a value.
18

7. TROUBLESHOOTING:
Please make sure that your phone’s Bluetooth is working. All the buttons in the app get faded or
their colors are changed when you touch them. Verify that your phone’s touchscreen works
properly, and If you use a case or screen protector for your phone, take them off temporarily be-
fore troubleshooting.
19
Problem Soluon
The app doesn’t nd the Smart Clean aer search-
ing.
1– check to see if the operang status light on the ORIOLE controller box
(JCA00-009001) is on. If the light is o :
• Disconnect the connector between the power harness and the planters
harness and check the voltage at the power harness’s end to be 12V.
The power harness has an in-line fuse . Check the fuse and your tractor
power supply if you don’t see any voltage .
• If there is voltage at the end of the power harness, then check the polar-
ity of the voltage. Make sure that the red wire is connected to posive
and the black wire is connected to negave.
2– If the operang status light is on, then reset the circuit by turning o the
power supply or disconnecng the connector between the power and plant-
ers harnesses.
3– Close the app, and reopen it.
4– Update your device’s Operang System (OS) version to ensure it uses
latest Bluetooth drivers.
The app nds the Smart Clean, but it doesn’t con-
nect.
This happens when another phone has been paired with the system. Reset
the circuit by turning o the power supply or disconnecng the connector
between power and planters harnesses to unpair the other phone.
The compressor works connuously and doesn’t
build up pressure.
Check all the tubing and connecons for air leaks .
The compressor works connuously and does build
up pressure.
Verify the compressor automac switch is wired correctly and works proper-
ly according to the compressor manufacturer’s instrucon included with the
compressor.
Air is leaking from the direconal valve muers. This happens when one or more air cylinders are defecve and have internal
leaks. To nd the defecve cylinders, adjust to 100% pressure and select the
Down posion on the main page of the app. Then test each individual cylin-
der by unplugging the cylinder’s boom air inlet. If air leaks out from the
cylinder boom air inlet, the cylinder has an internal leak and needs to be
replaced.
The “Down” seng li the row units and the “Up”
seng lower them.
It happens In some of the bracket designs, where the staonery end of the
cylinder is located under the row cleaner pivot point. Switching the air outlet
tubes on the plumbing box will x the problem.
App doesn’t respond and appears frozen. Check OS version . Smart Clean requires iOS 11 or later or the latest version
of Android . Some older device's may not be compable. Remove phone
case to verify it is not prohibing your touch screen.

• This template is full scale. Use it to mark drilling points.
• Plumbing box dimensions are 11.5” X 6.25” X 6.25”
• Use 3/8” bolts or U-bolts to install the plumbing box. (Bolts
are not supplied)
20
Table of contents
Popular Farm Equipment manuals by other brands

FPM Agromehanika
FPM Agromehanika 627 152 ASSEMBLY / OPERATION/ MAINTENANCE, SPARE PARTS LIST

Standen
Standen TSP 1900 Operator's handbook

Suevia
Suevia KRAZZMAXX IV Mounting and operation instructions

Land Pride
Land Pride AFM4214 Series Operator's manual

IntelligentAg
IntelligentAg Engage Zone Control Maintenance manual

Toro
Toro E-Z Vac Z Master Z400 Series Operator's manual