USER MANUAL
MI 405
Ammonia Medium
Range Meter
Dear Customer,
Thank you for choosing a Martini product. This
manual will provide you with the necessary infor-
mation for the correct use of the instrument.
Please read it carefully before using the meter.
This instrument is in compliance with directives.
Range 0.00 to 9.99 mg/L (NH3-N)
Resolution 0.01 mg/L
Precision ±0.10 mg/L @ 5.00 mg/L
LightSource Blue LED 466 nm
LightDetector Silicon Photocell and 466 nm
narrowbandinterferencefilter
Method Adaptation of Nessler method
Environment 0 to 50°C (32 to 122°F);
100% RH max.
Battery Type 1 x 9 volt
Auto-Shutoff After 10' of non-use
Dimensions 192 x 104 x 52 mm
(7.5 x 4.1 x 2”)
Weight 380 g
SPECIFICATIONS:
ISTMI405 03/05
MEASUREMENT PROCEDURE:
1• Turn the meter on by pressing ON/OFF.
2• When the LCD displays “- - -”,
the meter is ready.
3• Fill the cuvet with 10 mL of
sample, up to the mark, and
replace the cap.
4• Place the cuvet into the holder
and ensure that the notch on
the cap is positioned securely
into the groove.
5• Press ZERO and “SIP” will blink
on the display.
6• After a few seconds the
display will show “-0.0-”. The
meter is now zeroed and ready
for measurement.
7• Remove the cuvet. Open it.
8• Add 4 drops of NH3-1 (10 drops in case of
seawater analysis) and swirl gently.
9• Add 4 drops of NH3-2 (10 drops in case of
seawater analysis). Replace the cap and
swirl gently.
10• Immediately reinsert the cuvet
into the holder and ensure that
the notch on the cap is posi-
tioned securely into the groove.
11• Press and hold READ for 3
seconds and the display will
show the countdown prior to
the measurement.
Alternatively, wait for 3 minutes
and 30 seconds and just press
READ. In both cases “SIP” will
blink during measurement.
12• The instrument directly displays the concen-
tration in mg/L of ammonia nitrogen (NH3-N).
13• To convert the reading to mg/L of ammonia
(NH3), multiply by a factor of 1.216.
Interferences
• Organic compounds like: chloramines, vari-
ous aliphatic and aromatic amines, glycine,
(positive error).
To eliminate these interferences distillation
is required.
• Organic compounds like: aldehydes, alcohols
(e.g. ethanol) or acetone (negative error).
To eliminate these interferences distillation
is required.
• Sulfide (S2-): may cause turbidity.
• Hardness above 1 g/L as Calcium Carbonate
(CaCO3).
GUIDE TO DISPLAY CODES:
Thispromptappearsfor1 second
each time the instrument is
turned on.
The dashes “- - -” indicates
that the meter is in a ready
state and zeroing can be per-
formed.
Sampling In Progress. Flash-
ing “SIP” prompt appears each
time the meter is performing a
measurement.
“-0.0-”, the meter is in a zeroed
state and measurement can
be performed.
The blinking "BAT" indicates
that the battery voltage is get-
ting low and the battery
needs to be replaced.
“-bA-”, the battery is dead and
must be replaced. Once this
indication is displayed, the
meter will lock up. Change the
battery and restart the meter.
“Conf”, the meter has lost its
configuration. Contact your
dealer or the nearest Martini
Customer Service Center.
ERROR MESSAGES
On zero reading
•Blinking “-0.0-” indicates
that the zeroing procedure
failed due to a low signal-
to-noise ratio. In this case
press ZERO again.
•“no L”, the instrument can not
adjust the light level. Please
check that the sample does
not contain any debris.
•“L Lo”, there is not enough
light to perform a measure-
ment. Please check the
preparation of the zero
cuvet.
•“L Hi”, there is too much
light to perform a measure-
ment. Please check the
preparation of the zero
cuvet.
On sample reading
•“-SA-”, there is too much
light for the sample mea-
surement. Please check if
the right sample cuvet is
inserted.
•“Inv”, the sample and the
zero cuvet are inverted.
•“ZErO”, a zero reading was
not taken. Follow the in-
struction in the measure-
ment procedure for zeroing
the meter.
BATTERY REPLACEMENT
Battery replacement must only take place in a
non-hazardous environment.
Simply rotate the battery cover on the back of
the meter.
Detach the battery from the termi-
nals and attach a fresh 9V
battery while paying
attention to the
correct polarity.
Insert the battery
and replace the
cover.
•Under range. A blinking
“0.00” indicates that the
sample absorbs less light
than the zero reference.
Check the procedure and
make sure you use the
same cuvet for reference
(zero) and measurement.
•A flashing value of the
maximum concentration in-
dicates an over range con-
dition. The concentration of
the sample is beyond the
programmed range: dilute
the sample and re-run the
test.
ACCESSORIES:
MI505-100 Ammonia MR Reagent
(100 tests)
MI0001 Glass cuvets (2 pcs)
MI0002 Caps for cuvets (2 pcs)
MI0003 Stoppers for cuvets (2 pcs)
MI0004 Tissue for wipping cuvets
(4 pcs)
MI0005 9V battery (1 pc)
WARRANTY
This instrument is warranted against defects in mate-
rials and manufacturing for a period of two years
from the date of purchase.
If during this period the repair or replacement of parts
is required, where the damage is not due to negli-
gence or erroneous operation by the user, please
return the meter to either distributor or our office in
the original packing and the repair will be free of
charge.
Damages due to accidents, misuse, tampering or
lack of prescribed maintenance are not covered.
ISTMI405 03/05

Other Martini Instruments Measuring Instrument manuals

Martini Instruments Mi 106 User manual

Martini Instruments

Martini Instruments Mi 106 User manual

Martini Instruments MI 605 User manual

Martini Instruments

Martini Instruments MI 605 User manual

Martini Instruments MI 406 User manual

Martini Instruments

Martini Instruments MI 406 User manual

Martini Instruments pH 55 User manual

Martini Instruments

Martini Instruments pH 55 User manual

Martini Instruments MI 805 User manual

Martini Instruments

Martini Instruments MI 805 User manual

Martini Instruments MI 415 User manual

Martini Instruments

Martini Instruments MI 415 User manual

Martini Instruments pH 58 User manual

Martini Instruments

Martini Instruments pH 58 User manual

Martini Instruments Mi 105 User manual

Martini Instruments

Martini Instruments Mi 105 User manual

Martini Instruments MI 413 User manual

Martini Instruments

Martini Instruments MI 413 User manual

Martini Instruments MI 408 User manual

Martini Instruments

Martini Instruments MI 408 User manual

Martini Instruments MI 170 User manual

Martini Instruments

Martini Instruments MI 170 User manual

Martini Instruments MI 415 User manual

Martini Instruments

Martini Instruments MI 415 User manual

Martini Instruments pH 56 User manual

Martini Instruments

Martini Instruments pH 56 User manual

Martini Instruments MI 404 User manual

Martini Instruments

Martini Instruments MI 404 User manual

Martini Instruments MI 411 User manual

Martini Instruments

Martini Instruments MI 411 User manual

Martini Instruments MI 306 User manual

Martini Instruments

Martini Instruments MI 306 User manual

Martini Instruments Mi 160 User manual

Martini Instruments

Martini Instruments Mi 160 User manual

Martini Instruments MI 806 User manual

Martini Instruments

Martini Instruments MI 806 User manual

Popular Measuring Instrument manuals by other brands

Somogyi Elektronic Home MVT 808ACE instruction manual

Somogyi Elektronic

Somogyi Elektronic Home MVT 808ACE instruction manual

Stanley Tabs 25222 User instructions

Stanley

Stanley Tabs 25222 User instructions

LaMotte Tracer 1766 manual

LaMotte

LaMotte Tracer 1766 manual

Tektronix P6209 instruction manual

Tektronix

Tektronix P6209 instruction manual

Siemens SICAM Q200 7KG97 manual

Siemens

Siemens SICAM Q200 7KG97 manual

Keysight N9010AK-MTU Installation note

Keysight

Keysight N9010AK-MTU Installation note

Vaisala SHM40 user guide

Vaisala

Vaisala SHM40 user guide

Galvanic Applied Sciences 943-TGS-CE Operation manual

Galvanic Applied Sciences

Galvanic Applied Sciences 943-TGS-CE Operation manual

Nieaf-Smitt EazyAmpPLUS manual

Nieaf-Smitt

Nieaf-Smitt EazyAmpPLUS manual

Agilent Technologies Cary 60 user guide

Agilent Technologies

Agilent Technologies Cary 60 user guide

ABB Relion RES670 Operator's manual

ABB

ABB Relion RES670 Operator's manual

HENNING MSM12 V3 manual

HENNING

HENNING MSM12 V3 manual

Ambient Weather WS-25 user manual

Ambient Weather

Ambient Weather WS-25 user manual

TSI Instruments AIRASSURE 8144 Operation and maintenance manual

TSI Instruments

TSI Instruments AIRASSURE 8144 Operation and maintenance manual

Tektronix 1L10 instruction manual

Tektronix

Tektronix 1L10 instruction manual

AIR SYSTEMS INTERNATIONAL AQT-02 operating manual

AIR SYSTEMS INTERNATIONAL

AIR SYSTEMS INTERNATIONAL AQT-02 operating manual

Ahlborn ALMEMO 2390-5 operating instructions

Ahlborn

Ahlborn ALMEMO 2390-5 operating instructions

Inepro PRO1 Series manual

Inepro

Inepro PRO1 Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.