POWER DISTRIBUTION UNIT
Before you begin
Check to ensure the existence of earth wire before power supply.
Connect the power cord in the right way, keep an eye on power
consumption.
Power consumption
Read the followings carefully before the installation or operation
of this product
1.
This Power Distribution Unit (PDU) is for indoors use only.
2.
Check to ensure that the marked nominal voltage is same as the service
voltage in the country or region. Any in conformity of such voltages is
strictly forbidden.
3.
For safety power consumption, check to ensure that the supply line is
grounded. Power cord, plug and socket shall be in good conditions.
4.
For safety power consumption of devices in a cabinet, check to ensure
that the maximum power of such electronics or electrical equipment is
less that the maximum output power of this PDU. Any over-load
operation is forbidden.
5.
Never install PDU where excessive moisture is present.
6.
Never install any electrical equipment or distribution unit during a
lightning storm.
7.
This PDU is compatible with a power plug with the same socket only,
connection to any other type of plugs may result in an unexpected event.
8.
Only use supplied brackets for mounting.
9.
To reduce the risk of electrical shock when grounding cannot be
verified in good conditions, disconnect the product from power outlet
before installing or connecting any equipment, reconnect to the power
outlet only after making all connections.
INSTALLATION & OPERATION MANUAL
10.
Any unauthorized dismantling of the product is not permitted. The
Company shall not be responsible for any damages resulting from
unauthorized dismantling.
11.
Occurrence of any disorders during the operation shall be the case to
stop the power supply immediately, the case to disconnect the plug and
to call a local authorized dealer for their professional service.
Read the followings carefully after power supply:
1.
When the PDU with 10KA/1800 Joules surge
+
module
When the green LED indicator lights, the surge protection function of
this unit is normal; If not, the surge protection function of this unit is
invalidation, here need you draw out the surge protection module, and
plug in a new one, the surge protection function will come back.
2.
When equipped with a fast-fused protective system
When a fuse is blew out without power output, disconnect the connected
equipment from the power supply, turn the screw on the over-load
protective device in a count-clockwise direction and remove the fuse.
Use a new fuse with the same specification when failures are eliminated,
put the new fuse in the protective device, turn the screw in a clockwise
direction. A tight securing of the screw ensures a normal operation.
2 3

POWER DISTRIBUTION UNIT INSTALLATION & OPERATION MANUAL
4. When equipped with an over-load automatic protective switch:
A disconnected switch shall be the case to disconnect the connected
equipment. A push on the reset button on the switch when failures are
eliminated ensures a normal operation.
2. The removable brackets of horizontal type PDU can be installed
according your choice.
5. When PDU with minimum circuit breaker
When the minimum circuit breaker cut off the circuit loop, please switch
off the power supply. After obviate failure, switch on the circuit breaker,
then can connect the power supply.
Frontal installation
Inverse installation
Mounting
Mounting option
PDU is compatible with standard cabinet (482.6mm / 19 ) or non-standard
cabinet.
1.
PDU can be mounted on the frame in a horizontal way or on both sides
of the cabinet in a vertical direction.
PDU
Frontal side installation
PDU
Inverse side installation
2.
PDU can be mounted on the front or rear side of the frame in a
horizontal way.
Mounting bracket
1. Before the product leave factory, the brackets are installed at the two
ends of PDU
Mounting methods
Sample
1.
Choose a proper location for mounting, install two caged nuts (supplied),
align the nuts with the holes in the frame
Mounting bracket Mounting bracket
Caged nuts
Caged nuts
4 5
PDU

POWER DISTRIBUTION UNIT INSTALLATION & OPERATION MANUAL
2.
Align the mounting holes on the bracket with the installed caged nuts,
insert and turn a screw in the tightened position
Warranty and service
Warranty
The Company warrants PDU to be free from any defects in material and
workmanship for a period of two years from the date of purchase. Its
obligation under this warranty is limited to repairing or replacing, at its
sole option, any such defective products
This warranty does not apply to equipment that has been damaged by
accident, negligence or misapplication or has been altered or modified in
any way
Technical service
For your defective PDU, you can
1.
Contact your local dealer for technical support
2.
Note the specification, batch number, serial number and date of purchase
3.
Call Customer Support or authorized sales and service center on the
phone, the technician will be there at the first time to handle the defects
General policies
Reproduction in whole or in part without permission is prohibited. Logos
and patents herein mentioned are registered within respective jurisdictions.
All other trademarks, product names and corporate names are the property
of their respective owners and are used for informational purpose only
Accessory listing (Optional fittings)
Caged nuts M6
2 PCS
Turn
M6
2
PCS
6 7
This manual suits for next models
1
Table of contents
Other Maruson Power Distribution Unit manuals