Massage Therapy Concepts VPOD TUW20 User manual

MASSAGE
THERAPY
CONCEPTS
®
V
USER MANUAL FOR
VPOD Wireless TENS, EMS & NMES Unit

Table of Contents
Introduction
Safety Instructions
Intended Use
Contraindication
Important Safety Precautions
Battery Handling and Usage
Cautions
Adverse Reactions
Package Contents
Part Names and Functions on the Device
Dening TENS, EMS and NMES
VPOD Key Benets
04
05
05
05
06
10
11
13
14
15
17
19

Operating Instructions
Starting Your Treatment
Screen Functionality
Storing and Removing
Cleaning
VPOD Modes
Troubleshooting
Specications
Limited Warranty
20
24
27
33
34
37
50
54
56

4
INTRODUCTION
Thank you for purchasing the VPOD Wireless Tens Unit.
The VPOD tens unit can work with one or two VPODS at the same time. This wearable electrotherapy
device is designed to alleviate chronic muscle and joint pain on multiple body locations. It delivers TENS
(Transcutaneous Electrical Nerve Stimulation) technology and EMS therapy through the simple, convenient
control of the VPOD iOS or Andriod app. Premium, contouring pads allow for discreet and convenient
placement on multiple pain locations on the body.
Tens is a safe and drug-free treatment for pain that has been used for over 30 years by medical professionals
such as physical therapists and chiropractors.
Notes:
•Keep this instructional manual in a convenient place or store it with the device for future reference
•Register your product online at www.massagetherapyconcepts.com/warranty

5
SAFETY INSTRUCTIONS
This instruction manual provides you with important information about this device. To ensure the safe and
proper use of this device, read and understand all of the safety and operating instructions.
INTENDED USE
The VPOD is intended for the relief of pain associated with sore and aching muscles of the lower back, arms,
legs, shoulders and feet due to strain from exercise or normal every day and work activities.
CONTRAINDICATIONS
Do not use this device if you have a cardiac pacemaker, implanted debrillator or other implanted metallic or
electronic devices. Such use could cause electric shock, burns, electrical interference or death.

6
IMPORTANT SAFETY PRECAUTIONS
• Use under the guidance of your medical practitioner
• Do not use this unit near shortwave therapy equipment
• Do not place electrode pads near your heart
• Stop using the VPOD immediately if you feel any abnormality in your body or if you suspect the VPOD
is not operating normally
• Treatment time should not exceed 60 minutes
• Turn o the VPOD before you do vigorous movements, remove, or change positions of the electrode
pads
• Consult with your physician before using this device. If you have had medical or physical treatment
for your pain, consult with your physician before using this device.
• If your pain does not improve, becomes more than mild, or continues for more than ve days, stop
using the device and consult with your physician

7
•Do not use the device if you have any of the following medical conditions:
•Implanted cardiac pacemaker, defibrillator or other implanted metallic or electronic devices
•If you are pregnant
•If you have epilepsy
•Consult your medical practitioner if you have the following conditions:
•Diagnosed with cancer
•Have suffered acute trauma or recently have had a surgical procedure
•Have cardiac problems or cardiac disease
•Have an abdominal hernia
•Have venous thrombosis
•This device is intended for use by adults. Consult with your doctor if planning on using the unit on
children. It should only occur under adult supervision.
•Electrode pads should not be applied near your heart because the introduction of electrical current
into the chest may cause rhythm disturbances to your heart which can be lethal.

8
Also,do not place the electrode pads on the head, temples, eyes, mouth, throat (especially the
carotid sinus) or placed on the thorax and the upper back or passing through the heart.
•Do not use on genitals, skin lesions, infected areas, open wounds, rashes, swollen, red, infected or
inamed areas of skin eruptions such as phlebitis, thrombophlebitis and varicose veins
•Do not place the pads over your throat because this could cause severe muscle spasms resulting in
closure of your airway, diculty in breathing, or adverse eects on heart rhythm or blood pressure
•Never use the device while driving, operating machinery or during activities in which involuntary
muscle contractions may endanger others
•Do not use the device when bathing, showering, sleeping, during exercise, while sweating or in high
humidity
•Do not apply stimulation while driving, operating machinery, or during any activity in which electrical
stimulation can put you at risk or injury
•Do not use this device while using another TENS device
•Never immerse the device in any liquid

9
• Do not apply stimulation in the presence of electric monitoring equipment such as cardiac monitors
and ECG alarms because the equipment may not operate properly when the device is in use
• Keep away from other electronic equipment
• Never bend or fold the pads
• Apply the pads only to normal, intact, clean, healthy skin of adult patients
• For hospitals and clinics: Operation in close proximity (ex 1m) to shortwave or microwave therapy ME
equipment may produce instability to the stimulator output

10
BATTERY HANDLING AND USAGE
• To prevent the risk of overheating, re or explosion:
• Do not puncture, crush, disassemble or modify the device
• Do not throw the device into re
• Do not recharge, use or leave the device in any high temperature environment such as in a
location near a re or in direct sunlight
• The device contains a build-in rechargeable Lithium-ion battery which must be disposed of properly.
Dispose of the device according to applicable local government regulations.
• Do not disassemble the device by yourself

11
CAUTIONS
•If you suspect or have been diagnosed with heart issues, use only under the recommendation of
your doctor
•If you suspect or have been diagnosed with epilepsy, you should follow precautions recommended
by your physician
•Consult with your physician prior to using the device after recent surgical procedures because
stimulation may disrupt the healing process
•Use caution if stimulation is applied over the menstruating uterus
•Use caution if stimulation is applied over areas of skin that lack normal sensation
•Use the device only with components provided by VPOD packaging and accessories recommended
by the manufacturer
•Place the pads at least 1 inch apart. Do not place the adhesive surface of the pads directly on the
spine
•Do not apply the pads with wet hands and do not apply the pads that are wet
•Pads are for single patient use only. Never share the pads with another person.

12
• Do not overlap or put the pads on top of each other because therapy may weaken or stop
• Do not leave the pads placed on the skin after treatment
• Do not apply any lotion, cream or ointment to the pads
• Never attempt to modify the device
• The pads should not touch any metal object such as a belt buckle or necklace
• To avoid damage to the adhesive surface of the pads, only put the pads on the skin or the plastic pad
holder
• Always place clean pads in accordance with illustrations provided
• If the device is not functioning properly or you feel discomfort, immediately stop using the device
• Clean or change the pad when it loses adhesion
• Do not put any metal objects, such as coins, clips or other metal on the charger
• Do not put the pad on your body where it cannot be reached by your own hand

13
ADVERSE REACTIONS
• If you experience skin irritations, headaches or other painful sensations during or following the
application of electrical stimulation, consult with your physician prior to continuing using the device

14
PACKAGE CONTENTS
• VPOD TENS/EMS Unit with a rechargeable lithium-ion battery
• 1 Large Pre-gelled single-sided electrode pad
• 2 Medium Pre-gelled single-sided electrode pads
• Electrode pad holder
• Hard-cover travel case organizer for your VPOD and accessories
• USB to micro-USB adapter charging cable
• Wall AC adapter
• User Manual and Warranty Card
• Acupuncture Chart

15
PART NAMES and FUNCTIONS ON THE DEVICE
Front
Light Indicator
Power Button
Charging Port
Color indicator
Blue Light Blinking – Waiting to be paired with a
smartphone
Red Light Blinking – Device A is paired and in use
Green Light Blinking – Device B is paired and in use
Solid Blue – Device is charging
No Light – When device is fully charged the light
will shut o

16
Back
Connection Holes: These holes are used to attach the VPOD to the pad

17
DEFINING TENS, EMS and NMES
What is TENS?
The term TENS means Transcutaneous Electrical Nerve Stimulation is a weak electrical current applied to the
surface of the skin to stimulate the nerves beneath. TENS devices are available without a prescription and are
used as a non-invasive nerve stimulation method intended to reduce both acute and chronic pain. Electrodes
are placed on the skin on your pain points. The VPOD has sixteen TENS modes. Refer to the VPOD Modes
section for the list. ( Modes: 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 16, 17, 18, 23)
What is EMS?
The term EMS stands for Electrical Muscle Stimulation. Similar to TENS, weak electrical current is applied
to the surface of the skin, but to stimulate muscle contractions. It is used for strength training for athletes,
and rehabilitation for immobilized patients, among other uses. Electrode pads are placed on the skin near
the muscles that are to be stimulated. The impulses mimic the signals that comes from the central nervous
system, causing the muscles to contract. The VPOD has seventeen EMS modes. Refer to the VPOD Modes
section for the list. (Modes: 1, 4, 5, 6, 7, 9, 10, 11, 13, 14, 15, 17, 19, 20, 21, 22, 23)

18
What is NMES?
The Term NMES is Neuromuscular Electrical Stimulation. It is a safe, low-frequency current that sends small
electrical impulses to nerves causing contractions, blocks pain pathways & reduces swelling and edema. The
electrical stimulation can increase strength and range of motion and oset the eects of disuse. It is often
used to “re-train” or “re-educate” a muscle to function and to build strength after a surgery or period of
disuse. It is also used for weak or paralyzed muscles. It helps to increase muscle strength, blood circulation,
and range of motion and to lessen muscle spasms. (Mode 24)

19
VPOD KEY BENEFITS
•TENS, EMS, NMES – 3 Therapies in one device
•Wireless – User friendly app for iPhone and Andriod
•24 Modes – for pain relief and muscle recovery
•Full Body – muscle, nerve, join relief and recovery for back, shoulders, hips, legs, elbows, knees and
more
•Portable – Light-weight VPODS are designed for on the go and at home treatment
•Safe – non-invasive wireless device provides eective relief for a drug free pain solution. Lock
functionality protects against accidental therapy changes
•Treatment time – Up to 60 minutes
•Eective Relief - The unit provides eective results. The advanced technology sends out multiple
preset electrical therapeutic waves through the electrodes. These waves stimulate the combination
of deep tissue pain relief techniques and various muscle movements, while relieving muscle tension.

20
OPERATING INSTRUCTIONS
PREPARING FOR USE
Before using the device, inspect these items and ensure that the pads are not damaged, and that the device
is intact and working
FIRST TIME USE
STEP 1 - CHARGING VPOD
1. To charge your VPOD, insert the micro-USB plug of the adapter cable into the VPOD
2. Plug the other end of the cable with the USB plug into the wall adapter or computer
3. When charging is complete, remove the plugs and the charger. It will take about 2 hours
to fully charge.
Table of contents
Other Massage Therapy Concepts Fitness Equipment manuals