manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Massoth
  6. •
  7. Control Unit
  8. •
  9. Massoth eMOTION 8242060 User manual

Massoth eMOTION 8242060 User manual

Other Massoth Control Unit manuals

Massoth 8157001 User manual

Massoth

Massoth 8157001 User manual

Massoth DiMAX 1210Z User manual

Massoth

Massoth DiMAX 1210Z User manual

Massoth DiMAX 280R User manual

Massoth

Massoth DiMAX 280R User manual

Massoth DiMAX 8175201 User manual

Massoth

Massoth DiMAX 8175201 User manual

Massoth DiMAX 100A User manual

Massoth

Massoth DiMAX 100A User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

eMOTION Kesselfeuermodul
eMOTION Firebox Light Module
8242060
2
1. Einleitende Information
Das Kesselfeuermodul sorgt mit 2
LED‘s (orange und rot) für ein rea-
listisches Flackern eines Kohle- oder
Holzfeuers. Das Modul kann direkt
in den Stehkessel einer Dampok
eingebaut werden. Es eignet sich
aber auch als Lagerfeuer- oder
Kaminsimulation. Der Anschluss
erfolgt über Lötanschlüsse.
1.1 Lieferumfang
• Kesselfeuer-Platine
• Bedienungsanleitung
2. Wichtige Informationen zur
Inbetriebnahme
Das Kesselfeuer kann direkt am
Gleis mit Gleich- , Wechsel- oder
Digitalspannung betrieben werden.
Eine Polarität ist nicht zu beachten.
2.1 Anschluss
Die Beschaltung des Kesselfeuers
sehen Sie in Abbildung 1. Weitere
Anschlusshinweise nden sie in
Kapitel 3 dieser Anleitung.
1. General Information
Using only two LEDs (orange and red)
the eMOTION rebox light simulates
realistically the ickering light of a
wood or coal re. This module may be
installed directly behind the re door
of a steam locomotive. The eMOTION
rebox light may also serve as a camp
re or replace simulation. Two solder
pads are provided for the hook-up.
1.1 Scope of Supply
- rebox light module
- Instruction manual
2. Important information
The eMOTION rebox light may be oper-
ated with AC, DC or DCC power. The
module is not polarity sensitive.
2.1 Hook-up
Please nd the wiring diagram in
illustration 1 below. Additional wiring
diagrams are shown in chapter 3.
3
2.2 Einbau
Das Kesselfeuer sollte mit 2 Schrau-
ben oder doppelseitigem Klebeband
sicher befestigt werden. Achten Sie
darauf, dass es keinen Kurzschluss
mit Metallteilen in der Lok gibt.
Wenn nötig, können die Befesti-
gungslaschen entfernt werden.
Für einen noch besseren Flacker-
effekt kann man den beiliegenden
Reektor ankleben. Vor der Montage
des Reektors müssen die schwar-
zen Distanzröhrchen an den LEDs
mit einem Seitenschneider entfernt
werden. Danach können Sie den Re-
ektor mit etwas Sekundenkleber auf
der Unterseite des Reektors mittig
zwischen den 2 LEDs befestigen.
2.2 Installation
The rebox light is installed with either
two screws or double-sided tape. Make
sure to avoid any short circuits caused
by metal parts of the locomotive. The
mounting straps may be removed if
necessary. For an even better icker
effect you can stick on the enclosed
reector. Before mounting the reector,
the black spacer tubes on the LEDs
must be removed with a side cutter.
Then you can x the reector with
some superglue on the underside of
the reector in the middle between the
2 LEDs.
Abbildung 1: Allgemeine Anschlussbelegung
Illustration 1: General hook-up
4
3. Erweiterte Möglichkeiten
3.1 Anschluss eines Puffers
Das Kesselfeuer verfügt nicht
über interne Pufferkondensatoren.
Um eine stabilere Spannung zu
erzeugen, können Sie an „+“ und „-“
Kondensatoren (z.B. 470µF / mind.
25V) anschließen. Wenn Sie den
Massoth-Spannungspuffer verwen-
den, verbinden sie „Rot“ mit „+“
sowie „Schwarz+Weiß“ mit „-“.
Achten Sie beim Anschluß von Puf-
ferkondensatoren unbedingt auf die
Polarität, bei Verpolung besteht
Explosionsgefahr!
3. Additional applications
3.1 Hook-up of an additional buffer
The eMOTION rebox light does not
come with a power buffer (capacitor).
You may connect capacitors (e.g. 470µF
/ min. 25Volts) to “+” and “-“to improve
the power stabilization. In case you use
the Massoth power buffer connect the
red wire to “+” and the black and white
wires to “-“.
Warning: You must connect the capaci-
tors in the correct polarity. Danger of
explosion if connected with inverted
polarity!
oder / or
Entfernen / Remove
Abbildung 2: Einbau Reektor
Illustration 2: General hook-up
5
Abbildung 3: Anschluss eines Pufferkondensators
Illustration 3: Hook-up of a power buffer
4. Technische Daten
Versorgungsspannung
0 .. 24V AC / DC / DCC
Maximale Stromaufnahme
20mA bei 24V
4.1Gewährleistung & Kundendienst
MASSOTH gewährt die Fehlerfreiheit
dieses Produkts im Rahmen der
gesetzlichen Vorgaben, mindestens
jedoch für 1 Jahr ab Kaufdatum. Um
Reparatur- oder Serviceleistungen in
Anspruch zu nehmen, übergeben Sie
das Produkt bitte Ihrem Fachhändler
oder senden es direkt an den Her-
steller. Unfreie Sendungen werden
4. Technical Data
Power supply
0 .. 24Volts AC / DC / DCC
Maximum Current
20mAmps at 24Volt
4.1 Warranty, Service, Support
MASSOTH warrants this product against
defects in materials and workmanship
for one year from the original date of
purchase. Other countries may have dif-
ferent legal warranty situations. Normal
wear and tear, consumer modications
as well as improper use or installation
are not covered. Peripheral component
damage is not covered by this warranty.
6
nicht angenommen. Eine Kopie des
Kaufbelegs sowie ein einwandfreies
Prüfetikett auf dem Produkt werden
vorausgesetzt. Für Schäden durch
unsachgemäße Behandlung oder
Fremdeingriff oder Veränderung des
Produkts besteht kein Gewährlei-
stungsanspruch. Der Anspruch auf
Serviceleistungen erlischt unwider-
ruich. Verschleißteile sind von der
Gewährleistung ausgeschlossen.
Auf unserer Internetseite nden Sie
die jeweils aktuellen Broschüren,
Produktinformationen, Dokumenta-
tion und Softwareprodukte rund um
MASSOTH Produkte. Irrtümer und
Änderungen vorbehalten.
4.2 Hotline
Gerne stehen wir Ihnen für
Rückfragen zu diesem Produkt zur
Verfügung. Sie erreichen uns per
eMail unter: [email protected]
Die telefonische Hotline ist unter
+49 (0)6151-35077-38
zu bestimmten Zeiten geschaltet.
Die Telefonzeiten werden angesagt.
Valid warranty claims will be serviced
without charge within the warranty
period. For warranty service please
return the product to you dealer or send
it directly to the manufacturer. Return
shipping charges are not covered by
MASSOTH. Please include your proof of
purchase with the returned goods.
Please check our web site for up to
date brochures, product information,
documentation and software updates.
Errors and changes excepted.
4.2 Hotline
We will be happy to answer your ques-
tions about this product.
You may reach us via eMail at:
[email protected]
The phone hotline is available at
+49 (0)6151-35077-38
at specic operational hours.
Operational hours are announced.
7
QUALITY
MADE IN
GERMANY
991047 BDA 8242060
2019.05
032377o
RoHS
COMPLIANT
Massoth Elektronik GmbH
Frankensteiner Str. 28 · D-64342 Seeheim · Germany
FON: +49 (0)6151-35077-0 · FAX: +49 (0)6151-35077-44