2Product Information & Specifications
Note: Other types of plug are also available, please check with our sales engineers directly.
This manual describes the installation and connection of the product and also describes how to
use the product. Mounting and installing of the Octopus Series LEDs may only be executed by
certified service personnel. Please read and understand this manual completely before using the
product. Only use the product as specified in this manual.
2.1 General Information
Product Name Octopus Series LED Grow Lights
Manufacturer
Version US EU UK AUS
Plug Type US plug 120-277V EU plug 230V UK plug 240V AUS/NZS plug 240V
Input Voltage 120-277VAC 100-230VAC 100-240VAC 100-240VAC
Shenzhen VANQ Technology Co., Ltd.
AUS/NZS
plug 240V
US 5-15P US 6-15P US L7-15P EU plug 230V UK plug 240V
!
Octopus 800 Octopus 640 Octopus 200
TM

2.2 Technical specifications
SMD2835
+
SMD2835
+
SMD2835
+
800W ±5% 640W ±5% 200W ±5%
100-277VAC 100-277VAC 100-277VAC
277-480VAC 277-480VAC
OSRAM OSRAM OSRAM
0.82W ±5%
(250mA x 3.3V)
0.82W ±5%
(250mA x 3.3V)
0.82W ±5%
(250mA x 3.3V)
0.2W ±5% 0.2W ±5% 0.2W ±5%
Octopus 800 Octopus 640 Octopus 200
Input Power
Input Voltage(Standard)
HighInput Voltage(Optional)
Supplier
Model
LED Diodes - White
LED Diodes
- Single Color
Actual Working
Power per LED Diode
Rated Max Power per
LED Diode
Model
Total LED Diodes Number
Rated Max Power of all LED
Diodes per LED Fixture
(NOT ACTUAL POWER OF LED FIXTURE)
Actual Working Power per
LED Fixture / Rated Max
Power of all LED Diodes per LED Fixture
Relative Radiation Intensity
PPF(Photosynthetic Photon Flux)
Efficacy (100%-50% power)
Indoor Vertical Farming
Recommended Growing Area
(Indoor Vertical Farming)
Recommended Hanging Height From Canopy
(Indoor Vertical Farming)
Indoor Grow Tent
Recommended Growing Area
(Indoor Grow Tent)
Recommended Hanging Height From Canopy
(Indoor Grow Tent)
LED Fixture Weight
Dimensions
Working Temperature
Dimming
IP Rating
Supplier
Rated Max Power per
LED Diode
Actual Working
Power per LED Diode
2048pcs
0.66W ±5%
(300mA x 2.6V)
0.66W ±5%
(300mA x 2.6V)
0.66W ±5%
(300mA x 2.6V)
0.28W ±5% 0.28W ±5% 0.28W ±5%
1408pcs
3456pcs
2608W ±5%
31%
2160 μmol/s 1728 μmol/s 540 μmol/s
2.7-2.8 μmol/J 2.7-2.8 μmol/J 2.7-2.8 μmol/J
4ft x 4ft
1.2m x 1.2m
4ft x 4ft
1.2m x 1.2m
0.5-1.5ft
15cm-45cm
0.5-1.5ft
15cm-45cm
1ft-1.5ft
30cm-45cm
1ft-1.5ft
30cm-45cm
1ft-1.5ft
30cm-45cm
17 kg, 37.4 lbs 14 kg, 30.8 lbs
111.5cm L x 110cm W x 8.7cm D
43.9in L x 43.7in W x 3.42in D
111.5cm L x 110cm W x 8.7cm D
43.9in L x 43.7in W x 3.42in D
-20°C ~ 40°C | -4°F ~ 104°F
0-10V
IP43
5ft x 5ft
1.5m x 1.5m
4ft x 4ft
1.2m x 1.2m
2ft x 2ft
0.6m x 0.6m
32% 30%
1956W ±5% 652W ±5%
2592pcs 864pcs
1056pcs 352pcs
1536pcs 512pcs
Power
Light Source Details
Spectrum
PAR (Photosynthetically Active Radiation)
Recommended Applications
Physical
Certificates
_
_
_
_
4.1 kg, 9.02 lbs
57.5cm L x 54.5cm W x 8.5cm D
22.64in L x 21.46in W x 3.35in D
SMD3030
BLUE RED
+
SANAN
SMD3030
BLUE RED
+
SANAN
SMD3030
BLUE RED
+
SANAN
LED Diodes Qty per
LED Fixture
LED Diodes Qty per
LED Fixture

2.3 Compatible products and accessories
NOMINAL ELECTRICAL AC INPUT
Octopus 640
Dimming cables
Light Hanger
Power cord
Controller
Product
T-shape daisy chain connection dimming cable, 2m/6.5ft
Product Name Part Number
MG-VD100
MG-PC-US515
MG-PC-US615
MG-PC-USL715
MG-PC-EU230
MG-PC-UK240
MG-PC-AU240
MG-DCC-T01
MG-RH-01
MG-WR-01
0-10V dimming controller
Power cord with US plug 5-15P, 1.5m/5ft
Power cord with US plug 6-15P, 1.5m/5ft
Power cord with US plug L7-15P, 1.5m/5ft
Power cord with EU plug 230V, 1.5m/5ft
Power cord with UK plug 240V, 1.5m/5ft
Power cord with AUS/NZS plug 240V, 1.5m/5ft
1/8" Adjustable Ratchet Hangers 1.8m/6ft (Set of 2 - Holds
150 lbs/100Kg)
Steel Wire Rope Hanger 30cm/1ft (Set of 4 - Holds
150 lbs/100Kg)
Octopus 800
AC Voltage 120V 208V 230V 277V 347V 380V 400V 480V
5.37A 3.08A 2.78A 2.3A 1.85A 1.7A 1.6A 1.33A
644W 642W 641W 638W 641W 645W 642W 641W
0.98 0.98 0.98 0.98 0.98 0.98 0.97 0.97
AC Current
AC Power
Power Factor
* Octopus 200 is only available with 100-277VAC version.
AC Voltage 120V 208V 230V 277V 347V 380V 400V 480V
6.7A 3.85A 3.48A 2.89A 2.31A 2.11A 2.01A 1.67A
804W 802W 801W 798W 800W 803W 803W 801W
0.98 0.98 0.98 0.98 0.98 0.98 0.97 0.97
AC Current
AC Power
Power Factor
ORDERING CODE MATRIX FOR LIGHT FIXTURE
FAMILY MODEL INPUT VOLTAGE PLUG TYPE
Octopus 800 800W S
H
100-277VAC
277-480VAC
NEMA 5-15P
NEMA 6-15P
NEMA L7-15P
EU 230V
UK 240V
AUS/NZS 240V
Pigtail
640 640W
200 200W
US5
US6
USL7
EU
UK
AUS
P
* H is only available with
pigtail power cord.

The product is intended to be used in indoor growing environments. The product can be used in
wet environments.
The product may not be used outdoors. The Octopus Series LEDs light functions optimal when the
max ambient temperature is between 20~40°C.
2.4 Environment
2.5 Legal
CE LVD approval according to: EN 60598-2-1&EN 62471&EN 62493&EN 62778
CE EMC approval according to: EN 55015&EN 61547&EN 61000-3-2/-3
FCC
3Packing List
Please follow the content of the list and carefully check whether the purchased equipment and
accessories are complete. If you find that the actual product does not match the list, or the product
is damaged, please contact us immediately and provide photos or videos!
1.LED Fixture X 1
2.1/8" Adjustable
Ratchet Hangers X 2
4.Power Cord X 1 5.Dimming Cabie
(optional) X 1
6.VD-100 Controller
(optional, buy
separately) X 1
OFF
Just for
0-10V 100%
30%
60%
90%
20%
50%
80%
10%
40%
70%
VQ-VD100
Power Output Controller
888 %
3.Steel Wire
Rope Hanger X 2

4Safety Precautions & Warnings
Warning!
Carefully read the warnings below before using or working with the product!
5Installation
Warning!
Always adhere to the local rules and regulations when installing or using the LED light.
!
DO NOT connect to live power until installation is complete.
!
Do not open or disassemble the LED light. Opening or modifying the LED light can be dangerous
and will void the warranty.
Do not use the LED light when either the LED light or its power cord are damaged. Replace the
power cord only with original certified cords.
!
!
Modifications to the cords can lead to unwanted electromagnetic effects, which makes the product
not comply with legal requirements.
!
Do not expose the LED light to:
- (ambient) temperatures outside the specified range;
- dust and contamination;
- direct sunlight during use or HID light that could heat up the ballast.
!
Always disconnect the LED light from mains before performing any maintenance.
!
Always allow for a cool down period of at least 30 minutes before touching the LED bars. Touching
the LED bars when the light is lit or immediately afterwards can result in severe burns!
!
Do not use the LED light near flammable, explosive or reactive substances. Do not use sulfur
vaporizers or water misters.
!
The installation and use of the LED light is the responsibility of the end user. Incorrect use or
installation can lead to failure and damage to the LED light. Damage to the LED light and
electronic circuitry as a result of incorrect installation and use revokes the warranty.
!
!Mounting and installing of the LED light may only be executed by certified service personnel, in
accordance with the applicable local laws and regulations.
*All the LED fixtures in this series can be installed according to the same instructions.
!The installer is responsible for correct and safe installation.
!Ensure the local cabling can support the voltage and current requirements of the LED light.
!Avoid coiled cords and keep mains leads separated. This prevents electromagnetic interference.
!Do not connect or disconnect the LED light under load.
!Mount the system to something that can hold the weight of the LED light.
No.
1
2
3
4
5
6
2
1
2
1
1
Product Name Model Quantity
1.8m/6ft
1.5m
30cm/1ft
T-Shape
0-10V Dimming
Power Cord
Steel Wire Rope Hanger
1/8" Adjustable Ratchet Hangers
Octopus 800/640/200 800W/640W/200W 1
Dimming Cable(optional)
VD100 Controller(optional, buy separately)

The suggested height from the plant canopy to the LED light is:
During vegetative stage, 1ft - 1.5ft/30cm - 45cm
During flowering stage, 0.6ft - 1ft/15cm - 30cm
Below is the PPFD map of 5ft x 5ft/1.5m x 1.5m at 3 different hanging heights.
5.1 Mounting the LED driver onto the light fixture
5.2 Hanging the light fixture

Octopus 640Octopus 200 Octopus 800
Hanging Height: 6" (15cm)
4ft/1.2m
4ft/1.2m
5ft/1.5m
5ft/1.5m
Average PPFD of 5ft x 5ft footprint: 884 µmol/m²/s
Average PPFD of 4ft x 4ft footprint: 1195 µmol/m²/s
114 260 328 351 373 365 349 326 311 164
322 846 1123 1156 1248 1221 1145 884 356
370 978 1206 1266 1343 1338 1258 1205 975 404
382 988 1214 1270 1370 1366 1286 1201 968 416
388 982 1275 1308 1428 1401 1230 966 402
410 1004 1271 1338 1424 1397 1347 1288 985 396
360 992 1236 1313 1432 1413 1238 987 370
346 985 1275 1310 1333 1341 1234 978 388
254 815 1126 1168 1280 1243 1203 1101 878 296
138 332 349 357 371 374 345 334 318 146
1068
1337
1326
1424
Hanging Height: 12" (30cm)
4ft/1.2m
4ft/1.2m
5ft/1.5m
5ft/1.5m
Average PPFD of 5ft x 5ft footprint: 817 µmol/m²/s
Average PPFD of 4ft x 4ft footprint: 1002 µmol/m²/s
244 377 405 447 535 573 532 484 448 256
396 599 700 834 913 920 887 647 426
538 803 958 1078 1132 1159 1104 961 819 550
572 859 1025 1153 1221 1233 1176 1036 874 582
628 878 1050 1206 1278 1277 1090 898 638
616 896 1078 1173 1282 1281 1217 1083 917 654
590 887 1034 1188 1269 1274 1206 1055 900 616
554 829 979 1132 1186 1188 986 819 566
440 625 785 891 914 881 797 649 438
280 434 472 487 520 552 513 477 455 294
769
1211
1145
885
Hanging Height: 18" (45cm)
4ft/1.2m
4ft/1.2m
5ft/1.5m
5ft/1.5m
Average PPFD of 5ft x 5ft footprint: 724 µmol/m²/s
Average PPFD of 4ft x 4ft footprint: 834 µmol/m²/s
346 425 465 517 523 516 510 484 443 340
470 520 592 730 737 754 723 516 508
576 662 764 905 955 946 911 781 670 602
652 724 850 998 1052 1059 997 847 727 656
680 761 875 1032 1090 1090 883 754 710
702 757 857 1020 1068 1087 1025 871 779 694
658 716 846 997 1058 1067 1007 866 768 700
580 657 773 897 962 975 800 689 630
492 563 622 742 760 739 652 562 512
352 441 453 515 523 509 493 464 438 384
610
1032
915
790
95
216
273
292
311
304
291
272
259
137
268 705 936 964 1040 1018 954 737 297
308 815 1005 1055 1119 1115 1048 1004 813 337
318 823 1011 1058 1142 1139 1071 1001 806 347
323 819 1062 1090 1190 1167 1025 805 335
342 837 1059 1115 1187 1164 1122 1074 821 330
300 827 1030 1094 1194 1177 1032 822 308
288 821 1062 1092 1111 1117 1029 815 323
212 679 938 974 1066 1036 1002 918 732 247
115 277 291 298 309 312 288 279 265 122
890
1114
1105
1187
Hanging Height: 6" (15cm)
4ft/1.2m
4ft/1.2m
5ft/1.5m
5ft/1.5m
Average PPFD of 5ft x 5ft footprint: 736 µmol/m²/sAverage PPFD of 3ft x 3ft footprint: 631 µmol/m²/s
Average PPFD of 4ft x 4ft footprint: 996 µmol/m²/s
Hanging Height: 12" (30cm)
4ft/1.2m
4ft/1.2m
5ft/1.5m
5ft/1.5m
Average PPFD of 5ft x 5ft footprint: 681 µmol/m²/sAverage PPFD of 3ft x 3ft footprint: 537 µmol/m²/s
Average PPFD of 3ft x 3ft footprint: 482 µmol/m²/s
Average PPFD of 4ft x 4ft footprint: 835 µmol/m²/s
203 314 338 372 446 478 443 403 373 213
330 500 584 695 761 767 739 539 355
448 669 799 898 943 966 920 801 683 458
477 716 855 960 1018 1028 980 864 728 485
523 732 875 1005 1065 1064 909 749 532
513 746 898 978 1068 1067 1014 902 764 545
492 739 862 990 1057 1061 1005 879 750 513
462 691 816 943 988 990 822 683 472
367 521 654 743 762 734 664 540 365
233 361 393 406 433 460 428 398 379 245
641
1009
954
737
Hanging Height: 18" (45cm)
4ft/1.2m
4ft/1.2m
5ft/1.5m
5ft/1.5m
Average PPFD of 5ft x 5ft footprint: 603 µmol/m²/s
Average PPFD of 4ft x 4ft footprint: 695 µmol/m²/s
288 354 388 431 436 430 425 403
369
283
392 433 493 608 614 628 603 430 423
480 551 637 754 795 788 759 651 559 502
543 603 708 832 876 883 831 706 605 547
567 634 729 860 908 908 736 628 592
585 631 714 850 890 906 854 726 649 578
548 597 705 831 882 889 839 722 640 583
483 548 644 748 802 812 667 574 525
410 469 519 619 634 615 543 468 427
293 368 378 429 436 424 411 387 365 320
508
860
762
658
Hanging Height: 6" (15cm)
3ft/0.9m
3ft/0.9m
224 539 603 606 531 207
279 756 972 968 749 269
322 908 1117 1065 319
323 904 1115 1124 907 331
265 752 990 989 267
218 529 586 524 214
919
755
601
Hanging Height: 12" (30cm)
3ft/0.9m
3ft/0.9m
292 441 461 463 439 299
376 632 687 679 641 386
391 714 847 836 394
386 712 851 849 716 387
373 624 689 685 385
285 437 459 442 296
709
630
460
Hanging Height: 18" (45cm)
3ft/0.9m
3ft/0.9m
292 406 441 436 407 301
351 531 632 642 542 362
403 572 714 715 407
404 567 710 710 580 411
345 529 630 633 352
293 403 433 401 296
579
521
429

6Connecting LED Light To A Controller
5.3 Connecting the LED light to the mains
Warning!
!Make sure mains power is switched off.
Warning!
!Do not connect or disconnect the controller with LED light under load.
!Ensure the power cord and the controller cables do not touch any of the LED bars.
Using a daisy chain setup, a maximum of 50pcs LED lights can be connected to one controller.
The controller can dim the LED light from 0 to 100%.
• Connect the dimming cable to the dimming port on the first LED light.
• Use dimming cable (T-shape) to connect the dimming port of the following LED light.
• Repeat these steps to connect up to 50pcs LED lights.
!Ensure the cord is not coiled and does not touch any hot surfaces.
!Connect the cables according to local rules, safety regulations and electrical code.
!Ensure external switching gear can cope with the inrush current of the LED fixture. Always use a
double pole contactor suitable for switching a capacitive load. Never use household timers to
switch the LED fixture!
VD-100 0-10V
Dimming Controller
OFF
Just for
0-10V 100%
30%
60%
90%
20%
50%
80%
10%
40%
70%
VQ-VD100
Power Output Controller
888 %

8Storage and disposal
Inspection, maintenance and repair
!PLEASE NOTE: greater than 15% of the diodes must be non-functional before
the unit can be considered defective.
!Caution! Do not clean the LED fixture with detergents, abrasives or other aggressive substances.
9Warranty service
• Store the LED fixture in a dry and clean environment, with an ambient temperature of-20~85° C.
VANQ technology warrants the mechanical and electronic components of their product to be free
of defects in material and workmanship if used under normal operating conditions for a period of
three(3) years from the original date of purchase. If the product shows any defects within this
period and that defect is not due to user error or improper use, VANQ technology shall, at its
discretion, either replace or repair the product using suitable new or reconditioned products or
parts. In case VANQ technology decides to replace the entire product, this limited warranty shall
apply to the replacement product for the remaining initial warranty period, i.e. three(3) years from
the date of purchase of the original product. For service, return the LED light to your shop with the
original sales receipt.
• The product must not be discarded as unsorted municipal waste, but must be collected
separately for the purpose of treatment, recovery and environmentally sound disposal.
• Regularly check the LED fixture for dust or dirt buildup. Clean if necessary. Contamination may
cause overheating and decreased performance. Clean the outside of the LED fixture using a dry
or damp cloth.
• Regularly check the cables of the LED fixture to ensure it is undamaged.
Manual: Octopus 800/640/200
LED Grow Lights Manual
Changes reserved - Version 01/21
T. + 86 755 2904 2099
F. + 86 755 2904 2092
W. www.MasterGrowerLED.com
Shenzhen VANQ Technology Co., Ltd.
3#, BLDG B, Debaoli lndustrial park, NO.312, Jihua Road
Bantian, Longgang, Shenzhen, Guangdong China
Manufacturer
7
This manual suits for next models
3
Table of contents
Other Master Grower Lighting Equipment manuals