Matki MATKI ONE MOPR Series User manual

0947AF 05/19
13
Matki PLC, Churchward Road, Yate,
Bristol BS37 5PL
EN 14428:2008+A1
MATKI ONE
MOPR - RECESS INLINE PIVOT
INSTALLATION
PARTS LIST
MATKI PLC, CHURCHWARD ROAD, YATE, BRISTOL, BS37 5PL
Please pass the
Guarantee Card
to the customer.

2000
B
D
Before disposing of carton and/or commencing assembly, please check all the parts to ascertain that none are missing and they are all
undamaged. No claim for missing/damaged parts will be accepted once the packing carton has been disposed of and/or assembly has
commenced.
In case of query contact your Stockist with details of model number and details of serial number.
PREPARATION IMPORTANT
1. Please read complete installation instructions before fitting for Enclosure and Tray (if fitting).
2. We recommend the use of Safety glasses and Non slip gloves when handling the glass panels.
3. Ensure that the product can be fixed to a solid masonry wall or suitable timber stud work grade C16/C24 in the area behind the
Wall frames.
4. Shower trays or tiled floors must be absolutely level where enclosures are fitted
5. If fitting a tray we recommend a drainage test is carried out before the tray is tiled in position.
6. The assembly should be installed onto a waterproof wall covering and installed after the Tray and wall coverings are in place. Where
Tiling lips are provided Trays should be let into the Wall with the Tiling lip flush with the wall to allow the Tiling to overlap the Tiling lip.
7. Seal between tray and tiles. Remove any excess sealant from the area/joint between the tray and the tiles where the Wall Mount is
to be fitted. This will ensure the Wall mount fits correctly to the wall and tray/or tiled floor.
CAUTION: TEMPERED GLASS CANNOT BE CUT, POLISHED METAL AND CHROME CAN BE SCRATCHED. CAREFULLY
REMOVE ASSEMBLY FROM CARTON, DO NOT PLACE GLASS ON HARD FLOOR OR EXPOSE EDGES TO IMPACT.
IMPORTANT TOOLS REQUIRED
Masonry Drill bit 6mm, Tape Measure, Screw Drivers, Safety Glasses, Electric Drill, Level, Pencil,
Adjustable Spanners, Non Slip Gloves, 2mm/3mm/4mm Allen Keys
Dimensions are approximate
DIMENSIONS
LH OPENING
(AS FACTORY ASSEMBLED)
RECESS INLINE PIVOT
1000/1100/1200
RH OPENING
C - DOOR OPENING
A - OVERALL WIDTH
Model A B C D
MOPR1000 960-1000 80-100 482 329-349
MOPR1100 1060-1100 80-100 522 389-409
MOPR1200 1160-1200 80-100 622 389-409

x 3
x 3
x 3
b
a
2.5mm
Ø6
SILICON
x 3
x 3
STAGE 1
TOP VIEW FIXED PANEL
WALL MOUNT
THRESHOLD
This stage is describing the fitting of the Fixed panel wall mounts
Before fitting the enclosure please check that your product will fit the finished aperture size.(See dimensions)
a. Remove and set aside the threshold cover from the horizontal threshold. Place the horizontal threshold into position on tray. (If fitting
close to the front edge of the tray take into account that the front face of the fixed panel wall mount sits 2.5mm in front of the threshold). The
Pivot point in the threshold determines the handing of the door, for a door pivoting from the LH side, pivot point should be on the LH side, and
right for RH pivoting. Position the closure fixed panel wall mount on to the wall over threshold (wall mount has a top and bottom, Wall mount
cut-out with socket set screw is the top of the wall mount). Ensure the threshold adjuster fits up into the back of the wall mount extrusion in the
recess as shown. Adjust position of threshold adjuster as required, to adjust loosen screw 1 full turn, re-tighten after adjustment, do not over
tighten. Plumb the wall mount for upright and mark the fixing holes in the centre of the slots.
b. Drill 3 x fixing holes in the wall and insert wall plugs. Clean area and apply silicon sealant to the area behind the wall mount between the
tray and tiles and 100mm up the wall, central to the width of the wall mount. Fit the wall mount using the No.8 x 32mm Pan Head Screws.
c. Repeat as above for fixed panel wall mount on the pivot block side.
THRESHOLD
ADJUSTER
WALL
MOUNT
THRESHOLD
TOP
SEE DIMENSIONS
PIVOT POINT
(IMAGE SHOWS A
LH PIVOTING DOOR.
ROTATE THRESHOLD
BY 180° FOR RH
PIVOTING DOOR)

x 2
b
e
SILICON
a
c
1
1
2
2
STAGE 2
OUTSIDE
FACE
FOR BOTH PANELS
This stage is describing the fitting of both fixed panels. Before fitting the fixed glass panels adjust the threshold extrusion so that it
is equally positioned between the two wall mounts. Loosen the threshold adjusters at each end and lightly tighten in position as
required.
a. Apply a bead of silicon along the outer inside edge of the threshold extrusion in the recess provided up to the cut-out where both fixed
panels will be fitted.
b. Remove and set aside the panel stop fixing screws from the threshold extrusion.
c. Make sure the wall mount glass guard is pushed up fully to allow the glass to easily slot into the wall mount.
d. Lightly wet the edge of the fixed panel with soapy water and gently lower the panel down into the threshold extrusion first then along into
the wall mount.
e. As a guide the end of the edge of the fixed panel glass and extrusion should be positioned inline with the start of the cut out in the
threshold track (d) further slight adjustments may be required during the fitting of the door. Fix into position using the previously removed
screw.
f. Repeat as above (c-d) for the opposite panel.
WALL MOUNT
GLASS GUARD
SOAPY
WATER
SOAPY
WATER

x 2
x 2
a
b
c
3mm
d
STAGE 3
IMPORTANT
x 2
THIS IMAGE SHOWS THE
ASSEMBLY OF THE HEADRAIL
FOR A LH DOOR. ROTATE
HEADRAIL 180° FOR RH DOOR.
This stage is describing the fitting of the Top Track.
a. Loosen the fixings in the headrail adjusters to allow the adjusters to move freely in and out. Lower the top track into position,
ensuring the tongues on the headrail adjusters fit down into the back of the wall mounts. Using a long spirit level align the upper and
lower pivot points by adjusting the headrail left or right. Re-tighten the fixings in the headrail adjusters to fix in position.
b. Important - tighten the top track locking screws underneath the top track on both wall mounts to fix the top track to the wall
mounts.
c. Fit both the wall mount top caps (supplied in the kit of parts) to the top of the wall mounts.
d. Tighten the inline panel clamp to the headrail.

b
a
c
3mm
d
STAGE 4
HANDLE
GROOVES
ON UNDERSIDE
This stage is describing the fitting of the Door.
a. Lift the door and carefully guide the lower pivot block pin into the pivot block fitted to the threshold track.
b. From behind guide the upper pivot block pin fixed to the headrail into the cup in the pivot block fitted to the top of the door.
c. Rotate the pivot block disc with the socket csk screw 180° so that it secures the door in position. Tighten the socket csk screw.
d. Disassemble the handle by unscrewing the 2 x M5 x 12 Csk socket screws. Place the glass washers either side of the 2 holes in the
door glass. Re-assemble the handle to the glass and tighten into position with the grooved surfaces on the handle on the underside.

a
b
c
d
2mm
IN/OUTWARD
OPENING DOOR SEAL
(DOOR SHOWN IN OUTWARD
OPEN POSITION)
FIXED
PANEL
STAGE 5
DOOR
ADJUST
UNLOCK
IMPORTANT
LOCK
This stage is describing the Door adjustment.
a. Fit the door closure seal to the back of the door. The door closure seal can be adjusted away from the edge of the door to improve sealing
with the fixed panel or the fixed panel can be adjusted at the top to the seal. Important. The inward/outward seal requires sufficient
compression to the fixed panel glass. When initially opening the door both inwards and outwards the seal may deform unevenly and can
catch the fixed panel. Allow the seal to take a set in the closed position for 12 -24 hrs. Open the door inwards and outwards adjust as required
ensuring the seals works effectively for both directions of movement.
b. Fit the magnetic closure panel seal to the edge of the closure panel. Check the polarity of the magnet is correct with the magnet on the
edge of the door. This seal can be adjusted away from the edge of the fixed panel to meet the door magnetic seal or the fixed panel can be
adjusted at the top to the door. Check there are no gaps between the door and magnetic closure panel seal.
c. To adjust the door left to right at the upper pivot point, loosen the socket cap screw in the top of the headrail by one turn only and adjust
the door as required.
d. To adjust the door up and down at the lower pivot point, firstly loosen the locking screw in the lower pivot block. Then using the spanner
(supplied in the kit of parts) wind the nut at the base of the pivot block anti-clockwise to raise the door upwards. Important - Re-tighten
locking screw
CLOSURE
PANEL
FIXED
PANEL

SILICON
SILICON
SILICON
SILICON
a
b
c
d
e
x 2
SILICON
f
STAGE 6
INSIDE
CAP
This stage is describing the fitting of the covers and caps.
a. Apply a continuous bead of silicon all around the inside of the troughs in the threshold track between the edge of the fixed panel
and the lower pivot block and between the other side of the lower pivot block and edge of the closure fixed panel, as shown above.
b. Fit the two covers either side of the lower pivot block into the threshold track, so that the face of the covers is firmly pressed
against the face of the lower pivot block and ensure the slope on the cover is facing inward.
c. Apply a bead of silicon all around the inside of the recess in the threshold track where the threshold cover caps are to be fitted,
from the edge of the threshold cover all the way around to the edge of the fixed glass panel. Fit the threshold cover caps (supplied in
the kit of parts), with the slope facing inwards.
d. Fit the upper pivot block covers with colour detail disks over both sides of the upper pivot block and inline panel clamp. The inline
panel clamp covers are factory fitted on the panel for silver, black and white units. Remove and refit with the colour disks. The Inline
clamp covers are not fitted on bronze products or with optional copper and brass handle variants. These are included in the parts kit.
f. Fit the handle cover caps, press firmly into the ends of the handle.
SLOPE
INWARDS
SLOPE
INWARDS
FIXED
PANEL

SILICON
SILICON
100mm
SILICON
SILICON
ab
c
dd
e
SILICON
SILICON
100mm
SILICON
SILICON
SILICON
SILICON
SILICON
SILICON
STAGE 7
This stage is describing the final fitting of the Seals and Silicon
a. Fit the door horizontal seals to the bottom of the door, ensuring that the ends of the seal are firmly pressed up
against the side of the lower pivot block on both sides. The horizontal seal deflector faces inwards.Adjust the Horizon-
tal door seals down as required to meet the threshold. Pull off the vertical seal at the bottom on the pivot side and
apply a bead of silicon sealant at the end of the horizontal seal, refit the vertical seal. Apply a small bead of silicon to
the joints where the horizontal seals meet the inside pivot block cap.
b. The end of the horizontal seal must be flush with the edge of the door. Apply a bead of silicon sealant between the
bottom of the door and the horizontal seal, clean the silicon flush with the door edge.
c. Pull off the closure panel vertical magnetic seal at the bottom.Apply a bead of silicon along the top of the threshold
cover cap and vertical edge of the glass panel and refit the magnetic seal to the edge of the glass.
d. Apply a thin bead of silicon along the bottom edge of both the wall mounts and all the way up the outside of both
the wall mounts and the tiles. Apply a thin bead all the way along the threshold between the extrusion and finished
floor surface/tray. Continue around the joint where the threshold joins the wall mounts and also 100mm up on the
outside where the wall mount and glass meet.
e. Apply a bead of silicon on the outside around the joints between the threshold cover caps and threshold extrusion.
Masking tape can be used to achieve a tidy edge to the sealant. Remove the masking tape immediately and allow the
silicon to cure for 24 hours before using the shower.
MAGNETIC
SEAL
(FACTORY
FITTED)
DOOR
(OPEN)
FLUSH
TOP VIEW
DOOR
DOOR
(OPEN)
INSIDE
VIEW

17
13
14
29 12
30
1
31
4
63 5
65
36
64
67
61
66
42
28
64
20
52
66
71
60
54
53
17
61 16
43
19
PARTS LIST

QTY
PART No
DESCRIPTION
ITEM
1
7657 M CLEAR/PLAINPIVOT CLOSURE PANEL
1
1
8426 A SILVERPIVOT CLOSURE PANEL RAIL
2
1
1420 A SILVERNo.8 x 9.5 PAN POZI S.TAP ST.ST SCREW
3
4
1
8423 AF
PIVOT BLOCK
5
1
8258 AF
PIVOT HEIGHTADJUSTER
7
1
1360 A SILVERDIN 916 M4 X 8 SOCKET SET SCREW ST.ST
8
1
8253 AF
TOP PIVOT PIN
9
1
8589 A SILVERADJUSTING PIVOT BLOCK
10
1
8427 AF
ADJUSTER CLAMP
11
1
8261 AF
PIVOT BLOCK ADJUSTER SCREW
12
1
8573 A SILVER (1000) / 8574 ASILVER (1100) / 8575 A SILVER (1200)INLINE RECESS FLOOR RAIL
13
1
8576 A SILVER (1000) / 8577 ASILVER (1100) / 8578 A SILVER (1200)INLINE RECESS TOP TRACK
14
1
7672 M CLEAR/PLAIN (1000) / 7673 M CLEAR/PLAIN (1100,1200) / ???? M CLEAR/PLAIN (1400)INLINE RECESS PANEL
15
1
8586 A SILVER (1000) / 8587 ASILVER (1100,1200)INLINE RECESS GLASS PANEL RAIL
16
1
7630 A SILVER (1000) / 7631 ASILVER (1100) / 7632 A SILVER (1200)PIVOT THRESHOLD COVER
*17
2
7628 A SILVER/ WHITE/BLACK/BRONZEPIVOT WALL MOUNT
*18
2
8415 GREY/WHITE/BLACKWALL MOUNT GLASS GUARD
21
2
8266 AF
WALL MOUNT LOCKING SCREW
22
8
1752 AF
BS nsp 5mm DIA FOAM CORD INSERT
24
1
8404 GREYINLINE NOTCH CLAMP BODY
26
1
8403 GREYINLINE NOTCH PIVOT GUARD
27
2
8254 A SILVERPIVOT BLOCK CAP
28
1
8401 A SILVERINLINE PIVOT BLOCK CAP
29
1
8639 AF
QUINTESSE NOTCH CLAMP PIN
30
6
8579 AF
DIN O-Ring 0190-20
31
1
8679 AF
PIVOT DOOR MAGNET
32
33
1
8598 CLEARHORIZONTAL DOOR SEAL
34
1
7662 M CLEAR/PLAIN (1000) / 7663 M CLEAR/PLAIN (1100) / 7662 M CLEAR/PLAIN (1000)RECESS DOOR
35
1
8618 AF
PIVOT V DOOR CLOSURE SEAL
36
1
8422 A SILVERTOP PIVOT BLOCK
37
1
8413 GREYPIVOT SLEEVE TOP
38
1
8417 GREYTOP PIVOT GUARD
39
3
1503 A SILVERM5 X 20 CSK SKT SCREW ST.ST
40
1
8421 AF
PIVOT PIN
41
1
8255 A SILVERPIVOT DISK WITH COUNTERSINK
42
1
8256 A SILVERPIVOT DISK WITH BOSS
43
1
8414 GREYBOTTOM PIVOT GLASS BUSH
44
1
8418 GREYBOTTOM PIVOT GLASS BUSH 2
*45
2
1488 A SILVERM5 x 10 CSK SOCKET ST.ST
46
1
8762 CLEARPIVOT DOOR MAGNET CARRIER
47
1
8645 AF
PIVOT DOOR CLOSURE MAGNET C0923
48
1
0947 AF
MATKI ONE RECESS INLINE PIVOT
INSTALLATION INSTRUCTIONS
49
1
7364 A SILVER (7373 BRASS / 7373 COPPER)
MATKI ONE PIVOT KIT OF PARTS
50
1
7372 AF (SILVER/BLUE/GREEN/RED/GOLD/COPPER/BRASS
WHITE/BLACK)
MATKI ONE PIVOT DISK KIT OF PARTS
(DETAIL PACK)
51
1
DIN 557 -M6 SQUARE NUT ST.ST
52
2
1297 A SILVERDIN 916 M4 X 5 SOCKET SET SCREW ST.ST
1
8678 A SILVERPIVOT CORNER CLOSURE PANEL RAIL
QTY
PART No
DESCRIPTION
ITEM 61818 AF
WALL PLUG
55
1
8622 AF3mm AF BALL END
56
57
58
2
8441 A SILVERWALL MOUNT TOP CAP
59
2
8439 GREYHANDLE WASHER
60
2
8257 A SILVER
HANDLE CAP WASHER
61
1
8250 A SILVER
HANDLE CENTRAL BAR
62
6
1210 A SILVER
N.o8 x 38 PAN HEAD POZ S TAP ST/ST
63
1
7461 A SILVER
BRACKET HOLE COVER 17599 AF
111 10mm OPEN-END SPANNER 2
1417 A SILVERM5 X 12 CSK SKT SCREW 2
8641 A SILVERPIVOT DOOR HANDLE SLEEVE 2
8677 A SILVERRAIL CAP 1
2435 CLEARPIVOT SIDE HORIZONTAL SEAL 1
7629 A SILVERPIVOT THRESHOLD COVER SMALL
64 QTY
PART No
DESCRIPTION
ITEM 5
8252 A SILVERDECO DISK COVER RING 1
8269 A SILVERDECO DISK WITH CUT OUT
*68
5
8652 A SILVERDECORATIVE PIVOT DISK
69
1
8440 A SILVERDECO DISK WITH SEAL
70
2
8400 A SILVERDECORATIVE HANDLE CAP
71
2
8579 AF
DIN O-Ring 0140-20 1
4682 AF
MTKI PIVOT & QUINT DISPLAY PACK 1
1005 CHROMEMATKI CHROME EMBLEM
19
2
1282 A SILVER
M5 X 12 SKT DOMED ST.ST
20
23
25
53
54
65
*66
*67
???? M CLEAR/PLAIN (1500)
PARTS LIST
PIVOT DISK KIT OF PARTS
PIVOT KIT OF PARTS
MAIN INLINE PIVOT PACK
* colour variant on parts
This manual suits for next models
3
Table of contents