Matrix COSEC PATH DCFE User manual

Safety Instructions
These instructions are intended to ensure that the user can
use the product correctly to avoid danger or property loss.
Do not install the device:
Cautions
WARNING
ŸOn unstable surface.
ŸWhere ferromagnetic field or noise is induced.
ŸWhere static is created, such as desks made of plastics,
carpets.
ŸNear volatile inflammable materials or inflammable goods such
as drapes.
ŸWhere volatile gas and/or inflammable gas is created.
ŸInstalling and servicing should be done only by qualified
technician.
ŸThere are no user-serviceable parts inside.
ŸOpening or removing the device cover may result in electric
shock or exposure to other hazards.
ŸUse the device only for the purpose for which it was designed.
COSEC PATH
The Compact Door Controller
COSEC PATH DCCE/DCCM/DCCI
COSEC PATH RDCE/RDCM/RDCI
COSEC PATH DCFE/DCFM/DCFI
COSEC PATH RDFE/RDFM/RDFI
Quick Installation Guide
11.19"

COSEC PATH Variants
Things you will need
CONTENTS
Assigning IP Address and Other Network Settings
4
8
COSEC PATH as a Door Controller
COSEC PATH as a Reader
Concealed Wiring
Non-Concealed Wiring
Connecting PATH with a Cosec Server
Please read this guide first for correct installation and retain it for future reference. The information
in this guide is prevailing at the time of publication. However, Matrix Comsec reserves the right to
make changes in product design and specifications without prior notice.
Copyright
All rights reserved. No part of this document may be copied or reproduced in any form or by any
means without the prior written consent of Matrix Comsec.
Warranty
Limited Warranty. Valid only if primary protection is provided, mains supply is within limit and
protected, and environment conditions maintained within product specifications. Complete
warranty statement is available on our website:
www.matrixvideosurveillance.com
Technical Specifications - Door Controller
Installation
Know your PATH Controller
Know your PATH Controller
5
11
11
15
20
4
21
23
25
6
LED Indicator
Fingerprint
Sensor
RF Card
Sensor
COSEC DCF /RDFX X COSEC DCC /RDCX X
COSEC PATH Door Controller (DC) Variants: DCF , DCCX X
COSEC PATH Reader (RD) Variants: RDF , RDCX X
Here X stands for E/M/I where, E stands for EM Prox, M for
and I for HID iCLASS; types of a card.
COSEC PATH Variants
Technical Specifications - Reader
What’s your Package Contains
4
10
MIFARE R
3

What your Package contains Things You will Need
6
5
The Usage of a COSEC PATH
ŸCOSEC PATH Unit
ŸPower Adapter 12VDC, 2 Amp
ŸMounting Plate
Ÿ2 Screws 5/25
Ÿ2 Screw Grips
ŸPower Supply Cable with DC Jack
ŸEthernet Port Cable with RJ45 Plug
Ÿ10 Pin Cable Assembly
with Strip Connector
Ÿ5 Pin Cable Assembly with
Strip Connector
Ÿ120 E, 1%, 0.25W RS-485
Termination Resistor
ŸCOSEC PATH Unit
ŸMounting Plate
Ÿ2 Screws 5/25
Ÿ2 Screw Grips
Ÿ15 Pin CDC to CDC Cable Assembly
Ÿ15 Pin CDC Converter Cable Assembly.
ŸA Power Hand Drill
ŸA wire Stripper
ŸA Screw Driver Set
ŸInsulation Tap
ŸAccess to the COSEC Server Application to configure
COSEC PATH on to Server.
ŸA Stand-alone Computer with a Web Browser to change
the Network Settings of COSEC PATH.
The COSEC PATH can be used as a ‘Door Controller’ as well as a
‘Reader’ .
DCF /DCCX X
RDF /RDCX X

COSEC PATH as a Door Controller (DCF /DCC )X X
COSEC PATH DCF /DCC (Rear View)X X
ETHERNET
PWR GND Black
+12VDC IN Red
Brown
GND Black
White
Light Brown
RS232 TX
Rs232 RX
GND
TMPR NC/NO
W DATA1
W DATA0
HOLD
BEEPER
ALARM
STATUS
RED LED
GREEN LED
GND
+12VRDR
Grey
Pink
Black
Light Blue
Green
Blue
Yellow
Violet
Orange
Black
Red
RS-485 + EXIT SW
GND Black
EXIT SW
Brown
SHLD
RS-485 B
RS-485 A
White
Yellow
Blue
EXTERNAL READER
COM1
COM2
Green
Yellow
COM2 Yellow
COM1 Green
RX+ Blue
RX- Light Blue
TX+ Brown
TX- Light Brown
PWR
+12V LOCK
GND
Red
EM LOCK SIGNALS
+12V LOCK Red
GND
DOOR STS
GND
RLY NC
GND
RLY NO
RLY COM
Black
Black
White
Black
Blue
Brown
Light Blue
Yellow
5
CN1
CN2
Reset
CN2
CN1
12V/24V
12
3
4
5
DC 12V
Power Supply
To External Reader
RJ-45 Plug
Exit Switch
Exit
Panel200
Mounting Hook
Using External Power Supply
Using 12VDC of the Door
+12V LOCK
RLY NC
RLY COM
RLY NC
GND
RLY COM EM Lock
RS-485
Ethernet Cable
1
1
1
1
1
1
1
1
1
1
1
4
3
2
1
EM Lock
DC Power Jack
8
7

COSEC PATH as a Reader (RDF /RDC )X X
CN1
CN2
Reset
CN2
CN1
7
6
COSEC ARC
To Any COSEC Door Controller
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
ESC
ESC
ENT
ENT
To COSEC ARC Controller
RS-485
COSEC PATH RDF /RDC (Rear View)X X
1
1
Brown
GND Black
White
Light Brown
RS232 TX
Rs232 RX
GND
TMPR NC/NO
W DATA1
W DATA0
HOLD
BEEPER
ALARM
STATUS
RED LED
GREEN LED
GND
+12VRDR
Grey
Pink
Black
Light Blue
Green
Blue
Yellow
Violet
Orange
Black
Red
EXTERNAL READER
6
1
RS-485 + RDR PWR
GND Black
+12VRDR
Brown
SHLD
RS-485 B
RS-485 A
White
Yellow
Blue
1
7
10
9

Installation
Path can be installed as a Concealed and Non-concealed
wiring as described below.
A. Concealed Wiring
Step 1
Trace holes A, B & C and Drill along the markings
as shown below.
A
C
B
DCFX
Mounting
Plate
A
C
B
DCCX
Fix Mounting Plate with supplied screw grips & screws as
illustrated below.
Step 2
DCFXDCCX
A
C
B
A
C
B
Screw
Screw
grip
Hole
1. Connect cables and lead them through the rectangular
opening on the wall.
Step 3
12
11

DCCX
DCFX
DCFX
2. Align COSEC PATH on mounting plate and slide it downwards
as shown below.
DCCX
Fix the Mounting
Hook here
When in place, tighten captive screw at bottom.
Step 4
14
13

B. Non-Concealed Wiring
Step 1
Fix Duct Box Base Plate on Installation Surface using supplied
screws & screw grips as shown below.
DCFX
A
B
Duct Box
Base Plate
Fix the Mounting Plate on Duct Box Top Cover.
Step 2
A
B
Duct Box
Top Cover
Mounting
Plate
DCFX
The duct box shown in the illustration is not a part of the product
package and must be purchased separately.
Step 3
Align the COSEC PATH on mounting plate and slide it downwards
as shown on Next Page.
16
15

DCCX
Cables
DCFX
Cables
DCFX
DCCX
Connect cables and lead them through the bottom opening of
Duct Box as shown below.
Step 4
1. Fix the Top-Cover to Base Plate by sliding Mounting Hook of top-
cover into the Mounting Slot of base plate.
2. Tighten screws at the bottom as shown on Next Page.
Step 5
18
17

DCFX
DCCX
Connecting PATH with a COSEC Server
As a Direct Door
Ethernet Switch
Ethernet Switch
COSEC Panel
RS-485
COSEC Application
Server
Up to 32
Up to 255
As a Panel Door
20
19

Assigning IP Address and other
Network Settings
ŸOpen a Web browser on your computer.
ŸEnter the IP address of the PATH Controller, (default:
http://192.168.50.1), in the address bar of the browser and
press the Enter key on your computer keyboard.
ŸThe Login page appears*
.
ŸSelect the User Name as Admin.
ŸYou need to set the password, hence enter the desired password
in New Password and re-confirm the same in Confirm
Password.
ŸClick Login.
ŸClick the Network tab and enter the required network
configuration such as Door IP address, Server IP address etc.
ŸSave the Settings.
Power ON Blue ON/OFF
Online Light Blue ON
Offline Red ON
Degraded Mode Orange ON
LED Indication
Device Status
LED Status Indicators
22
21
* In case of PATH V1, you need to enter the User Name as admin
and Password as1234.

24
23
Technical Specifications-Door Controller
G E N E R A L
User Capacity
Credential
Supported
Input Power
Communication
Built in WiFi
Built in Bluetooth
Types of Card
Buzzer
Interface
Power Output
COSEC PATH DOOR Controller Variants
50,000
Ethernet & RS-485
RS - 232 and Wiegand
EM Prox
Card &
Finger-
print Card
Card &
Finger-
print
Card &
Finger-
print
LED
Yes (6hrs of battery backup on COSEC PATH BBU &
COSEC PATH PSBB)
Tamper Detection
R E A D E R
DCFE DCCE DCFM DCCM DCFI DCCI
SPECIFICATIONS
5,00,000
Event Buffer
12 VDC @2A
Battery Backup
Yes (IEEE 802.11 a/b/g/n)
HID i-class
Internal 12 VDC @0.250A
Yes
Yes
Yes (2 LEDs with Tri-colour)
Template
Storage Capacity
Yes
Card Card
SFM 5030: 9600 (1:N)
SFM 6030: 25,000 (1:N)
MIFARE R
P H Y S I C A L
E N V I R O N M E N TA L
Exit Switch Port
Door Status Sense
Door Lock Relay
Door Lock Power
Aux Input Port
Aux Output Port
Dimensions
(LxHxD)
Weight
Operating
Temperature
Storage
Temperature
Humidity
Range
No
No
Yes (2 State)
Yes
(Internal;12 VDC @0.5A)
Yes
Yes
DCFX: 50mm x 159mm x 42mm
5% to 95 % RH Non-Condensing
Minus 20° to 60°C
0° to 50°C
I N / O U T
SPECIFICATIONS DCFM DCFI
DCFE DCCE DCCM DCCI
COSEC PATH DOOR Controller Variants
0° to 45°C
DCCX: 50mm x 136mm x 33mm
DCFX: 375g
DCCX: 154 g
**The above listed technical specifications of Door Controller is for the
COSEC PATH V2 variants.

Technical Specifications-Reader
26
25
G E N E R A L
Credential
Supported
Input Power
Communication
Built in WiFi
Built in Bluetooth
Types of Card
Buzzer
COSEC PATH Reader Variants
Ethernet & RS-485
EM Prox
Card &
Finger-
print
Card
Card &
Finger-
print
Card &
Finger-
print
LED
Tamper Detection
RDFE RDCE RDFM RDCM RDFI RDCI
SPECIFICATIONS
12 VDC @0.250A
No
HID i-class
Yes
Yes
Yes (2 LED with Tri-colour)
No
Card Card
**The COSEC PATH V2 Door Controller is similar to the COSEC PATH V1 with
major improvements in its Processor and Communications.
**The COSEC PATH V1 variants has the User Capacity of 10,000 and Event
Storage capacity of 50,000. Also, the communication facility with Wi-Fi and
Bluetooth as well as the battery backup is not present in the PATH V1 Door
Controller.
MIFARE R
P H Y S I C A L
E N V I R O N M E N TA L
Aux Input Port
Aux Output Port
Dimensions
(LxHxD)
Weight
Operating
Temperature
Storage
Temperature
Humidity
Range
No
No
RDFX: 50mm x 160mm x 44mm
5% to 95 % RH Non-Condensing
Minus 20° to 60°C
0° to 50°C
I N / O U T
SPECIFICATIONS RDFM RDFI
RDFE RDCE RDCM RDCI
COSEC PATH Reader Variants
RDCX: 50mm x 136mm x 31mm
RDFX: 270 g
RDCX: 180 g

27
At the end of product life cycle; batteries, soldered boards,
metal components and plastic components must be disposed
through recyclers.
If you are unable to dispose-off the products or unable to
locate e-waste recyclers, you may return the products to
Matrix Return Material Authorization (RMA) department.
Disposal of Product after End-Of-Life
The product refered is covered by the waste Electrical and
Electronic Equipment (WEEE) directive and must be disposed
of in a responsible manner.
WEEE Directive 2002/96/EC
www.matrixaccesscontrol.com
Head Office
394-GIDC, Makarpura, Vadodara - 390010, India
Ph: (+91)1800-258-7747
Email: Suppor[email protected]
MATRIX COMSEC
V 3, December 2021
Other manuals for COSEC PATH DCFE
2
This manual suits for next models
11
Table of contents