GB - 1 GB - 5
Safety First! Specifications
Model: MDEHU10 MDEHU16
Power supply: 230V / 50Hz 230V / 50Hz
Air volume (max speed): 90m3/h 120m3/h
Power consumption: 250W 240W
Operating temperature: 5 - 35˚C 5 - 35˚C
Refrigerant*: R-134A, 120g R-134A, 165g
80%RH)
10 L/day(30˚C, 16 L/day(30˚C,
80%RH)
5 L/day (27˚C, 8 L/day (27˚C,
60%RH) 60%RH)
0.97 L/day (25˚C, 0.82 L/day (25˚C,
42%RH) 42%RH)
Tank size: 2.1 L 3.9 L
Net weight: 8.3 kg 10.8 kg
Dimension (W x D x H): 318 x 212 x 442 mm 335 x 230 x 530 mm
MDEHU10
MDEHU16
Please follow all the safety precautions listed below for safety and to
reduce the risk of injury or electric shock.
• Read all the instructions before using the appliance and keep them for
future reference.
• Retain the manual. If you pass the appliance onto a third party make sure
to include this manual.
• Check that the voltage marked on the rating label matches your mains
voltage.
• Do not pull on the main cable. Never move, carry or hang the appliance
by the mains cable.
• lf the mains cable is damaged, it must be replaced by the manufacturer,
it’s service agent, or similarly qualied persons in order to avoid a hazard.
• Always position the appliance with the mains plug in an accessible
position.
• The appliance must have clear space of 15cm on both sides and at the
back.
• To avoid personal injury or property damage, never insert ngers,
pencils or any other objects through the air inlet or outlet openings.
• Always keep the appliance in an upright position.
• To reduce the risk of electric shock, do not immerse or expose the
appliance or mains cable to rain, moisture or any other liquid.
• Before moving the appliance, rst switch it off then unplug and empty
the water tank.
• Leave the appliance to stand for two hour before connecting to the
mains socket after transport or when the appliance has been tilted (e.g.
during cleaning).
• Do not spray water or insecticides, aerosols or any other ammable
sprays on the appliance.
• Keep the appliance away from heaters and keep out of direct sunlight.
• Do not use the appliance for any other use than its intended one.
• This appliance is intended for normal indoor domestic / household use
only.
• This appliance is not intended for use by persons (including children) wit
reduced sensory or mental capabilities or lack of experience and
knowledge unless they have been given supervision or instructions
concerning the use of the appliance by a person responsible for their
safety.
• Close supervision is necessary for any appliance being used by or near
children.
• Children should be supervised to ensure that they do not play with the
appliance.
• Do not leave the appliance unattended when switched on - Switch off
and unplug the appliance when not use.
• Do not operate the appliance if it is malfunctioning, contact your service
agent.
• To avoid the risk of an electric shock do not attempt to repair this
appliance yourself.
*As listed in EU official journal (842/2006), refrigerant R-134A is a uorinated
greenhousegas covered by the Ryoto Protocol. Its global warming potential
(GWP) is 1300.
This symbol on the product or in the instructions means that your
electrical and electronic equipment should be disposed at the end of
its life separately from your household waste. There are separate
collection systems for recycling in the EU.
For more information, please contact the local authority or your
retailer where you purchased the product.
DSG Retail Ltd. Maylands Avenue Hemel Hempstead
Hertfordshire HP2 7TG England
Visit Partmaster.co.uk today for the easiest way to buy
electrical spares and accessories.
With over 1 million spares and accessories available
we can deliver direct to your door the very next day.
Visit www.partmaster.co.uk
Or call
0870 6001 338
(UK customers only)
Calls charged at National Rate.

GB - 4
GB - 2
Before Use
GB - 3
This dehumidier's ability to remove moisture is dependent on the
amount of moisture in the Air. If dehumidication has reduced the
humidity to a low level, less moisture can be removed from the air. It is
also more dicult to remove moisture from cold air than warm air.
1. Place on a stable, at oor. If the oor surface is not even:
• Vibration and noise will occur.
• Water may leak from the water tank
2. Make sure the suction and exhaust openings are clear and free from
blockage.
A. Power Indicator
B. Handle
C. Air Outlet
D. Air Filter
E. Air Inlet
F. Drain Tap
G. Water Tank
H. Castor
I. Permanent Drainage Hose
Know your Dehumidifier
1. Connect to the mains socket.
2. Make sure the water tank is correctly positioned.
The buzzer will sound for 3 seconds to alert you if the water tank
is full or not in position.
3. Switch ON the dehumidier and the buzzer will sound 3 times to start
operating.
Start operation
If the temperature is too low the dehumidier will automatically start to
defrost.
Defrost
Cleaning
• Clean the dehumidier by using a damp sponge, and dry it with a clean,
soft cloth.
• Never use alcohol or any product containing solvents.
• Do not immerse the dehumidier in water.
Hints and Tips
If your dehumidier does not operate:
• Check that the mains cable is connected to the mains socket
If the alarm sounds for 3 seconds:
• Check to see if the bucket is full or installed incorrectly.
If the dehumidifying function does not work:
• Check to see if the air lter if clogged.
• Check to see if the air intake or outlet is obstructed.
If you hear excessive noise:
• Check to see that the dehumidier is placed on a at stable oor
surface.
• Check to see if the air lter is clogged.
This dehumidier has a 3-min lag during start up in order to
prolong the compressor’s working life, the compressor will not
start until the dehumidier has run for 3 minutes.
When the water tank is full, the buzzer will sound for 3 seconds. The
compressor will also switch o automatically.
To empty the dehumidier, rst unplug from the mains socket then
carefully remove the water tank and empty the collected water. Replace
the water tank carefully before switching the dehumidier back on.
Full Bucket
Protect moisture sensitive items, eg :
• Bedrooms
• Studies
• Cellars / Basements
• Kitchens
• Musical instruments
• Cameras
• Computers
• Clothes
Benets:
• Prevents clothes and leather products from moulding.
• Dehumidies ooring and carpets.
• Prevents ceiling and windows from condensation.
• To obtain best results, try to avoid opening and closing windows and
doors.
• Storage rooms
• Libraries
• Galleries
• Computer rooms
Suitable for use in:
A
D
E
F
G
H
FI
B
C
OFF
Position
ON
Position
Power Indicator
Front View
Rear View
It is possible to connect the dehumidier
with the permanent drainage hose. Simply
connect one end of the permanent
drainage hose to the drain tap.
Ensure that the end of the permanent
drainage hose is lower than the drain tap
and the permanent drainage hose is not
bent. Otherwise, the water will not ow out continuously and water
leakage may occur.
Continuous Drainage
Capacity
The air lters located on the back of the dehumidier collect dust
contained in the air. To prevent the dust from clogging up the
dehumidier always use it with its air lter.
• The build up of dust reduces the
eciency of the dehumidier.
Always clean the air lter every 2
weeks. If the dehumidier
operates in a dusty atmosphere
clean the air lter more often.
• If the lters are obstructed, the
dehumidier will be less ecient.
• To remove the lter, pull up the plastic lip from above the vents as
shown.
• Clean the lter with a vacuum cleaner. lf the lters is very dirty, you can
wash them in warm water (never use hot or soapy water). Make sure
that the air lter is completely returning it to the dehumidier.
• Do not bend the lter.
MDEHU10
2.1 litres
10 litres per day
Water tank
Maximum capacity
(30˚C, 80%RH)
MDEHU16
3.9 litres
16 litres per day
This manual suits for next models
1
Popular Other manuals by other brands

Hafele
Hafele Wandleser WRU 220 Installation and maintenance instructions

Tetra
Tetra AquaArt 20 operating instructions

RapidLED
RapidLED Coralife BioCube 29 Aurora Array Retrofit manual

Oase
Oase BioMaster 250 operating instructions

Alesis
Alesis Data Disk Reference manual

Task Force Tips
Task Force Tips BLITZFIRE Series INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

Novus
Novus LogBox-3G instruction manual

Vicon
Vicon SVFT-C22 Installation and operation manual

HEIDENHAIN
HEIDENHAIN POSITIP 8000 operating instructions

Haldex
Haldex KN18530 Series installation instructions

Feig Electronic
Feig Electronic OBID Classic-Pro ID CPR.M02 Series installation manual

Indesit
Indesit IDVA 835 instruction manual