Meanwell A301-OOW User manual

Pure Sine Wave Power Inverter
600W I 1
OOOW
I 1500W
Technical data Rectifying faults
A
If
you have detailed questions on the specifications
of
the
V inverter please contact
us.
Item
number
Rated input voltage
Constant output power
Peak output power
(a
max. of 15 min.)
Maximum input current
Output voltage 115VAC
230VAC
Output frequency
Idle current 115VAC
Consumption 230VAC
Input voltage range
Low voltage alarm
Lowvoltage shutdown
Efficiency
up
to
Dimensions (mm)
Weight
A301~OOW
A301-1000W
12 V
DC
24
V
DC
12 V
DC
I 24 V
DC
600W
1000 W
1000 W
2000W
(650 W)
(1200W)
70 A 40 A 100 A 50 A
115VAC +/- 3%
230VAC +/- 3%
50 Hz or 60Hz
to
be
specified
O.
85A O. 45A
1.8
A 1.8A
1.4A
1A
1A
1A
10.
7V-15V
21.4V-30V
10
.7
V-15V
21.4
V-3~
V
< 10.7 V < 21.4 V < 10.7 V < 21.4V
<
10
V < 20 V <
10
V < 20 V
85 %
335 x 236 x
83
395 x 236 x
83
3kg
4
kg
Item
number
A301-1500W I
Rated input voltage
12
V
DC
24
V
DC
Constant output power
1500W
I
Peak output power
3000W
a
mal<'.
of
10
min.l (1800
W)
Maximum input current 200 A 100 A
Output voltage 115VAC 115VAC
+/-
3%
I
230VAC 230VAC
+/-
3% I
Output frequency
50
Hz
or
60Hz to
be
specified
Idle current 115VAC 1A 0.8A
Consumption 230VAC 2A 1.5A
Input voltage range 10.
7V-15V
21.4V-30V
Lowvoltage alarm <
10
.7 V < 21.4 V
Low voltage shutdown <
10
V < 20 V
Efficiency
up
to
85
%
Dimensions (mm 415 x 283 x
100
Weight 5.
75
kg
Fault Cause Remedy
No
output voltege, LED not
Illuminated Bad connection between bat-
tery and inverter.
Internal fuses defect.
Check the cables and contact
In this case send the unit
back
to
supplier.
No output voltageOVER-
The
inverter has been over- Switch offthe inverter and the
TEMP LED illuminates heated. . power consuming units.
Wait for approx. 5
-10
min-
Utes and switch
on
the
inverter only.
Reduce the loading and
ensure a better ventilation for the
inverter.
Then switch back
on
the
consuming unit.
Overload LED illuminates Current consumption of the
consuming unit
is
too high.
Possibly, there
is
a short cir-
cuit
in
the consuming unit.
Switch offthe inverter and
disconnect the consuming
units.
switch back
on
the inverter
only.
Ifthe
OVERLOAD LED
is
off, there
is
a short circuit at
the consuming unit or the
total load was higher than the
performance specified within
the technical data table.
Check the connecting cable
ofthe consuming unit for
mechanical damages.
Acoustic signal
in
case of
loading
-
Battery voltage too low. In
case of loading battery voltage
falls below 10.7 V resp.
21.4
V.
The battery must be recharged.
1
3
Make sure that the place
is
well ventilated.
If
installed into housing, ensure proper ventilation.
At least, keep a free space
of
10
cm around the
inverter.
Installing the inverter can be set horizontal or
vertical.
The air intake at the bottom
of
the inverter
and the air outlet
on
the back may not
be
blocked.
In
case
of
ambient temperatures of more
than 35°C (e.g. engine or heat ing rooms,
direct sunlight), the inverter will switch off
automatically, because ofthe activated self
heating feature.
2 Lay the flexible connecting cable (plus and minus)
from the battery
to
the connecting poles
of
the
inverter.
ill
Warningl
Make sure that the poles will not
be
exchanged! Reverse polarity connection
will blowthe internal fuses. Exchange of
fuses
by
experts only!
4 Fisrt connect the negative cable
to
the white
negative terminal.Connect
the
positive cable
to
the
red
positive terminal.
5 I 1:\
Warningl
~
In
order for the integrated residual current-operated
protective device
of
the 150S-12NE and 150S-24NE
inverters to work properly, the earth connection
of
the
inverter must be electrically connected
to
the chassis
of
the vehicle or boat.
Lay the flexible earth cable from the earthing point
of
the
vehicle to the earthing point of the inverter.
Connect the earth cable
to
the chassis terminal.
1:\ Warning!
~
Reverse polarity connection
of
the battery wires can
damage the inverter.
Do
not use the inverter with
electrical systems using pos itive ground.
6 $
I
ON
WJW
POWOR
INV
EICTER
[illF~
,
@~
OfT
o
$
ON/OFF
SW I
civertemp
output
socket
overload
CAUTION:
*Always
olace the inverter in
an
environment
which is :
(A) Well ventilted
(8)
Not
exposed
to direct
sunlight
or
heat
source
(C)
Out
of
reach from children
(0)
Away
from water/moisture,
oil
or
grease
(E)
Away
from any flammable
substance

This manual suits for next models

2

Other Meanwell Inverter manuals

Meanwell NTS Series User manual

Meanwell

Meanwell NTS Series User manual

Meanwell ISI-501 Series User manual

Meanwell

Meanwell ISI-501 Series User manual

Meanwell TS-700 User manual

Meanwell

Meanwell TS-700 User manual

Meanwell TS-1500 User manual

Meanwell

Meanwell TS-1500 User manual

Meanwell TN-3000 User manual

Meanwell

Meanwell TN-3000 User manual

Meanwell PB-300 User manual

Meanwell

Meanwell PB-300 User manual

Meanwell TS-1500 User manual

Meanwell

Meanwell TS-1500 User manual

Meanwell NTS-450 Series User manual

Meanwell

Meanwell NTS-450 Series User manual

Meanwell A301-1K0 User manual

Meanwell

Meanwell A301-1K0 User manual

Meanwell ERG-5000 User manual

Meanwell

Meanwell ERG-5000 User manual

Meanwell TS-200 User manual

Meanwell

Meanwell TS-200 User manual

Meanwell ISI-501 Series User manual

Meanwell

Meanwell ISI-501 Series User manual

Popular Inverter manuals by other brands

Tektronix RG 501 instruction manual

Tektronix

Tektronix RG 501 instruction manual

UNIVPO UNIV-15GTS user manual

UNIVPO

UNIVPO UNIV-15GTS user manual

Hobart Jet-Ex 4D Operation and maintenance manual

Hobart

Hobart Jet-Ex 4D Operation and maintenance manual

blubase roboost Roof Tiles Portrait manual

blubase

blubase roboost Roof Tiles Portrait manual

Mitsubishi Electric FR-A700 Series INSTALLATION GUIDELINE

Mitsubishi Electric

Mitsubishi Electric FR-A700 Series INSTALLATION GUIDELINE

Mitsubishi Electric FR-F820-00077 instruction manual

Mitsubishi Electric

Mitsubishi Electric FR-F820-00077 instruction manual

Nietz NZ2000 Series Operation manual

Nietz

Nietz NZ2000 Series Operation manual

ZUCCHETTI 3PH 10KTL-15KTL-V2 user manual

ZUCCHETTI

ZUCCHETTI 3PH 10KTL-15KTL-V2 user manual

Carrier ASPB07-1SI installation guide

Carrier

Carrier ASPB07-1SI installation guide

Felicitysolar IVGM4648 user guide

Felicitysolar

Felicitysolar IVGM4648 user guide

SEW-Eurodrive Movidrive MDX61B manual

SEW-Eurodrive

SEW-Eurodrive Movidrive MDX61B manual

LONCIN LC3000i Service manual

LONCIN

LONCIN LC3000i Service manual

LG N2W-L5 Series installation manual

LG

LG N2W-L5 Series installation manual

FoxESS S Series user manual

FoxESS

FoxESS S Series user manual

Control Techniques Commander SE SE11200025 user guide

Control Techniques

Control Techniques Commander SE SE11200025 user guide

Stanley PI120PSCA instruction manual

Stanley

Stanley PI120PSCA instruction manual

TOYODenki ed64sp instruction manual

TOYODenki

TOYODenki ed64sp instruction manual

Clenergy SPH50 Installation and operation manual

Clenergy

Clenergy SPH50 Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.