SPECIFICATION
NTS-450-112 NTS-450-124 NTS-450-148 NTS-450-212 NTS-450-224 NTS-450-248
25A
91%
14A
91%
25A
93%
14A
93%
MODEL NO.
OVER RATED POWER(3 Min.)
PEAK POWER(10 Sec.)
SURGE POWER(30 Cycles)
WAVEFORM Note.1
AC OUTPUT
AC REGULATION
VOLTAGE RANGE (Typ.)
EFFICIENCY (Typ.) Note.1
DC CURRENT (Typ.)
DC INPUT
DC INPUT
AC OUTPUT
ENVIRONMENT
FUSE (Internal)
SAFETY
&
EMC
LOW
HIGH
OVER TEMPERATURE
OUTPUT SHORT
BAT. POLARITY
GFCI PROCTECTION
PROTECTION
True sine wave (THD<3%)
50A
90%
40A*2 40A*1 10A*2
10A*240A*1
±3.0% at rated input voltage
88%
50A
40A*2
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
By internal fuse open
None
-25 ~ +70℃(Refer to “Derating curve”)
WORKING TEMP.
REMOTE CONTROL
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
20% ~ 90% RH non-condensing
o
-30 ~ +70℃ / -22 ~ +158 F, 10 ~ 95% RH non-condensing
RATED POWER(Continuous) 450W
OVER LOAD (Typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
Design refer to UL458
(Only for “GFCI” , by request)AC socket
WITHSTAND VOLTAGE DC I/P - AC O/P:3.0KVac AC O/P - FG:1.5KVac
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
OTHERS
PACKING 1.3Kg; 8pcs/ 11.4Kg/ 1.74CUFT
MTBF
DIMENSION 210*130*55mm (L*W*H)
NOTE
517.5W
675W
900W
FRONT PANEL LED
24V 48V 24V 48V
DC VOLTAGE 12V12V
OFF MODE CURRENT DRAW ≦1mA
BATTERY TYPES Lead Acid or li-ion
AC VOLTAGE 100 / 110 / 115 / 120Vac selectable by DIP S.W
Default setting set at 110VAC
200 / 220 / 230 / 240Vac selectable by DIP S.W
Default setting set at 230VAC
FUNCTION
ALARM
SHUTDOWN
RESTART
ALARM
SHUTDOWN
RESTART
= US, GFCI, UN = EU, CN, AU, UK, UN
NTS-450 series
450W High Reliable True Sine Wave DC-AC Power Inverter
Power ON-OFF remote control by front panel dry contact connector (by RELAY); Open : Normal work ; Short , Remote off
20 ~ 33Vdc 40 ~ 66Vdc 20 ~ 33Vdc 40 ~ 66Vdc10 ~ 16.5Vdc10 ~ 16.5Vdc
Please refer to page5
EMC IMMUNITY
EMC EMISSION
Parameter
Parameter
Radiated
Harmonic Current
Voltage Flicker
ESD
Radiated
Magnetic Field
11±0.3Vdc 22±0.5Vdc 44±1Vdc44±1Vdc22±0.5Vdc
10±0.3Vdc 20±0.5Vdc 40±1Vdc40±1Vdc20±0.5Vdc
11±0.3Vdc
10±0.3Vdc
12.5±0.3Vdc
15.5±0.3Vdc
16.5±0.3Vdc
15±0.3Vdc
25±0.5Vdc
31±0.5Vdc
33±0.5Vdc
30±0.5Vdc
12.5±0.3Vdc
15.5±0.3Vdc
16.5±0.3Vdc
15±0.3Vdc
50±1Vdc
62±1Vdc
66±1Vdc
60±1Vdc
50±1Vdc
62±1Vdc
66±1Vdc
60±1Vdc
25±0.5Vdc
31±0.5Vdc
33±0.5Vdc
30±0.5Vdc
SAFETY STANDARDS
NO LOAD
DISSPATION
(Typ.)
NON-SAVING MODE
SAVING MODE Default disable, ≦1.2W ~ 1.5W by models @ auto detec AC output load ≦10W will be changed to saving mode
10W 12W
10W
1.3W 1.5W
1.2W
10W 12W
10W
1.3W 1.5W
1.2W
File Name:NTS-450-SPEC 2021-04-26
Standard
Standard
FCC for 112,124,148 only(expect for Type-UN)
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)
Test Level / Note
Test Level / Note
Class A
Class A
BS EN/EN61000-3-2
BS EN/EN61000-3-3
-----
-----
BS EN/EN61000-4-2
BS EN/EN61000-4-3
BS EN/EN61000-4-8
Level 3, 8KV air ; Level 2, 4KV contact
Level 2 , 3V/m
Level 1 , 1A/m
281.3K hrs min. Telcordia TR/SR-332 (Bellcore) ; 85K hrs min. MIL-HDBK-217F (25℃)
CB IEC62368-1,Dekra BS EN/EN62368-1,E13,EAC TP TC 004,AS/NZS 62368.1 approved
(Please refer to next page“AC output socket” table for more details)
; Design refer to UL458 (By request)
℃
※:https://www.meanwell.com/serviceDisclaimer.aspx
(Note.3)
FREQUENCY Default setting set at 50Hz±0.1Hz
Default setting set at 60Hz±0.1Hz
50/60Hz selectable by DIP S.W 50/60Hz selectable by DIP S.W
BS EN/EN55024, BS EN/EN55035