Meanwell NTS-450 Series User manual

NTS-450 series
■
■
■
File Name:NTS-450-SPEC 2021-04-26
450W High Reliable True Sine Wave DC-AC Power Inverter
‧
‧
‧
‧
‧
‧
‧ ℃ ℃
‧
‧
‧
‧
‧
‧
‧
‧
℃
■
TPTC004
E13
IEC62368-1 AS/NZS 62368.1
■
‧
‧
‧
‧
‧
‧
‧-
‧
‧
EN62368-1

SPECIFICATION
NTS-450-112 NTS-450-124 NTS-450-148 NTS-450-212 NTS-450-224 NTS-450-248
25A
91%
14A
91%
25A
93%
14A
93%
MODEL NO.
OVER RATED POWER(3 Min.)
PEAK POWER(10 Sec.)
SURGE POWER(30 Cycles)
WAVEFORM Note.1
AC OUTPUT
AC REGULATION
VOLTAGE RANGE (Typ.)
EFFICIENCY (Typ.) Note.1
DC CURRENT (Typ.)
DC INPUT
DC INPUT
AC OUTPUT
ENVIRONMENT
FUSE (Internal)
SAFETY
&
EMC
LOW
HIGH
OVER TEMPERATURE
OUTPUT SHORT
BAT. POLARITY
GFCI PROCTECTION
PROTECTION
True sine wave (THD<3%)
50A
90%
40A*2 40A*1 10A*2
10A*240A*1
±3.0% at rated input voltage
88%
50A
40A*2
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
By internal fuse open
None
-25 ~ +70℃(Refer to “Derating curve”)
WORKING TEMP.
REMOTE CONTROL
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
20% ~ 90% RH non-condensing
o
-30 ~ +70℃ / -22 ~ +158 F, 10 ~ 95% RH non-condensing
RATED POWER(Continuous) 450W
OVER LOAD (Typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
Design refer to UL458
(Only for “GFCI” , by request)AC socket
WITHSTAND VOLTAGE DC I/P - AC O/P:3.0KVac AC O/P - FG:1.5KVac
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
OTHERS
PACKING 1.3Kg; 8pcs/ 11.4Kg/ 1.74CUFT
MTBF
DIMENSION 210*130*55mm (L*W*H)
NOTE
517.5W
675W
900W
FRONT PANEL LED
24V 48V 24V 48V
DC VOLTAGE 12V12V
OFF MODE CURRENT DRAW ≦1mA
BATTERY TYPES Lead Acid or li-ion
AC VOLTAGE 100 / 110 / 115 / 120Vac selectable by DIP S.W
Default setting set at 110VAC
200 / 220 / 230 / 240Vac selectable by DIP S.W
Default setting set at 230VAC
FUNCTION
ALARM
SHUTDOWN
RESTART
ALARM
SHUTDOWN
RESTART
= US, GFCI, UN = EU, CN, AU, UK, UN
NTS-450 series
450W High Reliable True Sine Wave DC-AC Power Inverter
Power ON-OFF remote control by front panel dry contact connector (by RELAY); Open : Normal work ; Short , Remote off
20 ~ 33Vdc 40 ~ 66Vdc 20 ~ 33Vdc 40 ~ 66Vdc10 ~ 16.5Vdc10 ~ 16.5Vdc
Please refer to page5
EMC IMMUNITY
EMC EMISSION
Parameter
Parameter
Radiated
Harmonic Current
Voltage Flicker
ESD
Radiated
Magnetic Field
11±0.3Vdc 22±0.5Vdc 44±1Vdc44±1Vdc22±0.5Vdc
10±0.3Vdc 20±0.5Vdc 40±1Vdc40±1Vdc20±0.5Vdc
11±0.3Vdc
10±0.3Vdc
12.5±0.3Vdc
15.5±0.3Vdc
16.5±0.3Vdc
15±0.3Vdc
25±0.5Vdc
31±0.5Vdc
33±0.5Vdc
30±0.5Vdc
12.5±0.3Vdc
15.5±0.3Vdc
16.5±0.3Vdc
15±0.3Vdc
50±1Vdc
62±1Vdc
66±1Vdc
60±1Vdc
50±1Vdc
62±1Vdc
66±1Vdc
60±1Vdc
25±0.5Vdc
31±0.5Vdc
33±0.5Vdc
30±0.5Vdc
SAFETY STANDARDS
NO LOAD
DISSPATION
(Typ.)
NON-SAVING MODE
SAVING MODE Default disable, ≦1.2W ~ 1.5W by models @ auto detec AC output load ≦10W will be changed to saving mode
10W 12W
10W
1.3W 1.5W
1.2W
10W 12W
10W
1.3W 1.5W
1.2W
File Name:NTS-450-SPEC 2021-04-26
Standard
Standard
FCC for 112,124,148 only(expect for Type-UN)
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)
Test Level / Note
Test Level / Note
Class A
Class A
BS EN/EN61000-3-2
BS EN/EN61000-3-3
-----
-----
BS EN/EN61000-4-2
BS EN/EN61000-4-3
BS EN/EN61000-4-8
Level 3, 8KV air ; Level 2, 4KV contact
Level 2 , 3V/m
Level 1 , 1A/m
281.3K hrs min. Telcordia TR/SR-332 (Bellcore) ; 85K hrs min. MIL-HDBK-217F (25℃)
CB IEC62368-1,Dekra BS EN/EN62368-1,E13,EAC TP TC 004,AS/NZS 62368.1 approved
(Please refer to next page“AC output socket” table for more details)
; Design refer to UL458 (By request)
℃
※:https://www.meanwell.com/serviceDisclaimer.aspx
(Note.3)
FREQUENCY Default setting set at 50Hz±0.1Hz
Default setting set at 60Hz±0.1Hz
50/60Hz selectable by DIP S.W 50/60Hz selectable by DIP S.W
BS EN/EN55024, BS EN/EN55035

NTS-450 series
450W High Reliable True Sine Wave DC-AC Power Inverter
DERATING CURVE
NTS-450-212NTS-450-112 NTS-450-224NTS-450-124 NTS-450-248NTS-450-148
AC Output Socket
LOAD (%)
LOAD (%)
AMBIENT TEMPERATURE (℃)
-25
10Vdc 10.5Vdc 16.5Vdc
20Vdc 21Vdc 33Vdc
40Vdc 42Vdc 66Vdc
10 20 30 40 50 60 70 (HORIZONTAL)
40
40
20
60
50
80
80
100
100
0
File Name:NTS-450-SPEC 2021-04-26
Socket type
MODEL NO.
TYPE-US
Standard Optional
Country
Certificate
TYPE-UK TYPE-UNTYPE-UN
TYPE-GFCI
USA U.K UNIVERSALUNIVERSAL
USA
Standard Optional Optional Standard Standard
CHINA
TYPE-CN TYPE-AU
AUSTRALIA
Standard
EUROPE
TYPE-EU
E13
None
E13
E13

NTS-450 series
450W High Reliable True Sine Wave DC-AC Power Inverter
File Name:NTS-450-SPEC 2021-04-26
Remote ON-OFF
Open
Short
AC Output Status
power inverter ON
power inverter OFF
Remote ON-OFF Control
AC Output Voltage、Frequency、Power saving mode selectable by DIP SW
Output voltage and frequency setting factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the voltage
and frequency, through the DIP switch of position 1,2,3,4 on the panel.
Type-US
AC OUTPUT
SW
R.C
Load
DC input
Status
SW1 SW2
OFF OFF : 100Vac or 200Vac
SW4
AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW
SW3
OFF ON : 110Vac or 220Vac
ON OFF : 115Vac or 230Vac
ON ON : 120Vac or 240Vac
ON : 50Hz
OFF: 60Hz
ON : Saving mode
OFF: Non-Saving mode
1
2

Status
DC Input
Load
LED Indicator
Status
Status
Status
Status
DC Input
DC Input
DC Input
Load
Load
Load
DC Input
Load
Normal work:
Abnormal status :
Green
Green
Green
Abnormal Indication
Inverter OK
12.5~15.5Vdc 11~12.5Vdc <11Vdc or >15.5Vdc
<22Vdc or >31Vdc
>80% load
<44Vdc or >62Vdc
25~31Vdc 22~25Vdc
50~62Vdc 44~50Vdc
<40% load 40~80% load
Output overload or AC output short circuit
Abnormal DC voltage
Over temperature or Fan lock
Inverter fail
Light
Light off
Flash
Orange
Orange
Orange
Remote off Abnormal Status
Saving mode (See below table)
Red
Red
Red
LED STATUS
NTS-450 series
450W High Reliable True Sine Wave DC-AC Power Inverter
File Name:NTS-450-SPEC 2021-04-26

NTS-450 series
450W High Reliable True Sine Wave DC-AC Power Inverter
55
direction
Air flow
ON
OFF
Reverse Polarity Will Damage The Unit.
DC INPUT
+-
Chassis
Bonding
Lug
R.C Connector : JST B-XH or equivalent
Remote Control Mating Housing
JST XHP JST SXH-001T
or equivalent or equivalent
Terminal
Pin 1,2 Open: Normal work
Pin 1,2 Short: Remote off
File Name:NTS-450-SPEC 2021-04-26
MECHANICAL SPECIFICATION
Unit:mm
45 120
210
119
130
9
16
7
Type-EU Type-US
AC OUTPUT
SW
R.C
AC OUTPUT
SW
R.C
Load
DC input
Status
Load
DC input
Status
Type-CN
(AC output side)
Type-UN
AC OUTPUT
SW
R.C
Load
DC input
Status
(DC input side)
AC OUTPUT
SW
R.C
Load
DC input
Status
1
2
1
2
1
2
1
2

NTS-450 series
450W High Reliable True Sine Wave DC-AC Power Inverter
Accessory List
※ Pull handle (Optional accessory, Power inverter and Pull handle should ordered seperately)
MW’s Order No.
NTS-Handle
Pull handle
Foot pad
1
4
Item Quantity
1
2
M4*2
File Name:NTS-450-SPEC 2021-04-26
Screw 2
3
Pull Handle
Foot pad
1
2

NTS-450 series
450W High Reliable True Sine Wave DC-AC Power Inverter
TYPICAL APPLICATION
1 Utility Input
2 AC/DC Battery Charge r
3 Battery Bank
4 Off-Grid AC/DC
Power Inverte r
AC Outlet 5
1 AC/DC Battery Charger
2 Battery Bank
3 Off-Grid DC/AC Inverter
4 AC Outlet
(Shore)
(PB/NPB/NPP series)
(PB/NPB/NPP series)
(NTS series)
(NTS series)
1
1
4
4
4
3
2
23
5
4
File Name:NTS-450-SPEC 2021-04-26
Please refer to : http://www.meanwell.com/manual.html
INSTALLATION MANUAL
TYPICAL APPLICATION
1 Battery Bank
2 Off-Grid DC/AC Solar Inverter (NTS series)
3 AC Outlet
1
3
2
This manual suits for next models
11
Table of contents
Other Meanwell Inverter manuals

Meanwell
Meanwell TS-700 User manual

Meanwell
Meanwell ISI-501 Series User manual

Meanwell
Meanwell PB-300 User manual

Meanwell
Meanwell ISI-501 Series User manual

Meanwell
Meanwell TS-1500 User manual

Meanwell
Meanwell A301-OOW User manual

Meanwell
Meanwell ERG-5000 User manual

Meanwell
Meanwell TS-200 User manual

Meanwell
Meanwell A301-1K0 User manual

Meanwell
Meanwell NTS Series User manual