Operating Instructions
For measurement
After pressing the “ZERO” switch, the LCD screen will display “.000” when in metric mode or “.0000” when in imperial
mode. This also indicates that the origin setting is completed. The test indicator is now ready for use.
Tolerance setting for measurement
Press the “TOL” button and a “▲”sign will appear on the LCD. Adjust the measuring lever so that the indicator displays
the upper measurement limit, and press “TOL” for confirmation. When the “▼”sign appears on the LCD, adjust the
measuring lever to display the lower measurement limit. Press the “TOL” button again for confirmation and the unit has
been set for tolerance measurement. During the tolerance measurement, when “▲”sign appears, it indicates that the
measuring value is in excess of upper tolerance. When the “▼”sign appears, it indicates the measuring value is below the
limit of the lower tolerance. If “OK” is displayed, the measuring value is within the tolerance range.
To cancel the tolerance settings, press “TOL” three times continuously,
Trouble shooting
Failure Possible Situation Solutions
Digits flash simultaneously on
LCD Battery power low Replace battery
Battery power low Replace battery
Nothing appears on LCD Battery has poor contact Clean the battery contacts
The display does not work (only
when changing the battery)
Circuit accidentally paused
caused by poor voltage when
changing the battery
Remove battery and replace it
after 30 seconds
Note! The battery supplied is only to test the system and may not have a full operating life
Specifications
Range: ±0.5mm/±0.02in
Resolution: 0.01mm/0.0005in
Total tolerance: 0.013mm
Return tolerance: 0.003mm
Repeatability: 0.003mm
Measuring force: ≤0.6N
Range of measuring force: ≤0.3N
Operating temperature: 0~+40
Storage temperature: -20~+60
Power: 1.5V SR44 (silver oxide cell) 1 battery
Battery life: 1 year continuous usage/ 3 years under normal operation
www.measumax.com