Mect TP1043 02 series User manual

ME7056_07
10/18
USER’S MANUAL
TP1043 02 series
HMI –Operator panel


HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
INDEX
1. Introduction.............................................................................................................. 1
1.1. Staff skill............................................................................................................ 1
1.2. Simbols............................................................................................................... 1
1.3. Terms ................................................................................................................. 2
1.4. Security .............................................................................................................. 2
1.5. REFERENCE MANUAL.................................................................................. 2
2. System description................................................................................................... 3
2.1. Specification....................................................................................................... 4
3. Mechanical dimensions ........................................................................................... 5
3.1. Panel mount........................................................................................................ 8
3.1.1. Distance........................................................................................................ 8
4. TP1043 02 wiring.................................................................................................... 9
4.1. Connections........................................................................................................ 9
4.2. Power supply...................................................................................................... 9
4.2.1. Insulation...................................................................................................... 9
4.2.2. System power supply ................................................................................... 9
4.2.3. Fuse ............................................................................................................ 10
4.3. ModBus wiring ................................................................................................ 10
4.4. CANOpen wiring.............................................................................................11
5. Peripherals .............................................................................................................12
5.1. USB.................................................................................................................. 12
5.2. Ethernet............................................................................................................ 12
6. HMI........................................................................................................................ 13
6.1. System variables .............................................................................................. 13
7. How to order.......................................................................................................... 13

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
1
1. Introduction
To grant a fast setup of the device please follow carefully the information in this
manual.
1.1. Staff skill
Products described in this manual are devoted to PLC programmers or automation
experts only. MECT S.r.l. declines any responsibility about malfunctioning or
damage caused by incorrect use of MECT devices, due to noncompliance to this
manual information. MECT S.r.l has an help desk.
1.2. Simbols
Danger
Follow this advice to avoid people injury.
Warning
Follow this advice to protect the device.
Caution
Follow this advice to have a more effective performance.
ESD ( Electrostatic discharge)
Danger: possibly damage due to Electrostatic discharge.
Note
Step to follow for a correct installation.
Additional information

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
2
1.3. Terms
PLC: TP1043 02
Terminals: MPNC005, MPNC010, MPNC020, MPNC030, MPNC035
System: PLC (TP1043 02) with terminals
1.4. Security Attention
Switch off devices before connecting them.
ESD (Electrostatic discharge)
Modules have electronic components that can be damaged by.
electrostatic discharge. Be sure to be connected to ground when
handle the devices.
The instrument has no power switch and no internal fuse, but it powers on
immediately after connecting a correct power supply input (check the power supply
value on the instrument label). Keep the power supply line as short as possible and
keep it separate from other power lines.
For security reasons it is necessary to have a 2 section power switch with a fuse near
the instrument and easily replaceable.
Avoid the presence of other power actuators in the same control panel, high humidity,
excessive heat and corrosive gas.
Instruments must have a power supply from security transformers or SELV
transformers.
1.5. REFERENCE MANUAL
The Quick Start (downloadable from the web site)
and MectSuite Tutorial are the reference manuals for
MectSuite to develop HMI and PLC applications.

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
3
2. System description
TP1043 02 is a device composed by a PLC and a HMI with touch-screen monitor
4.3” width and 480 x 272 pixel resolution with 262.000 colors.
TP1043 02 allows the supervision of networked devices Modbus RTU and Modbus
TCP. The networks are managed simultaneously by TP1043 02 and data from a
network can be sent on another thus creating a bridge between the two networks.
On TP1043 02 is present Micro-USB host port, that allows, with an adapter, the use
of an USB-pen drive for software updates and data log.
On TP1043 02 are up to 1 Kbyte of retentive variables stored on flash.
The device is also able to manage an up to 64GB wide, micro SD card. The SD card
is factory mounted on request.
A real-time clock buffered RAM maintains the date and time up to four months with
the device turned off.
TP1043 02 is equipped with a micro PLC to make a small automation of the process.
The device can be applied in horizontal or in vertical design with the option "V" (see
following pictures).
Figure 1: Front view TP1043 (horizontal version)
Figure 2: Front view TP1043 (vertical version)

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
4
2.1. Specification
TP1043 02 is based on a multiprocessor system. PLC and HMI are based on a
454MHz ARM9.
Table 1
Hardware characteristics
PLC Processor
ARM926JE 454MHz
RAM
128MB
FLASH
128MB
Non volatile variables
On FLASH memory
Real Time Clock
Yes with rechargeable battery
Screen
TFT 480 x 272 pixel 262k colors
Touch screen
Resistive 4 wires
Ethernet
10Mbit/s - 100Mbit/s self recognition
Micro-USB
Host 2.0
Micro SD
Max 64GB
Software characteristics
OS
LINUX 2.35
PLC
IEC61131-3
Graphics
Based on QT library
CAN
CanOpen 2.0
ModBus
Modbus RTU master
Storage memory
Possibility of history storage
Field bus main features
RTU Modbus
Master 2 wires
TCP Modbus
Client
Power supply
Power Supply 24VDC
12÷36Vdc - 150mA (24Vdc)
Power Supply 24VAC
24Vac ±20% - 150mA
Electromagnetic compatibility
The electromagnetic compatibility tests have been carried out at accredited
laboratories, acc ording to EN 61326-1, EN 61131-2 and EN 61000-6-2standards.

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
5
3. Mechanical dimensions
In the following figures see the TP1043 dimensions.
Panel with frame mounting and hooks fastening:
Encumbrance
Front view Side view
Mounting plate

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
6
Panel with frame mounting and screws fastening:
Encumbrance
Front view Side view
Mounting plate

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
7
Panel without frame mounting:
To mount it is necessary that the display is at the same panel height, so for metal
panels below 2,5mm it is necessary to insert a shim to reach the exact quote.
Front view Side view
Technical specification
Table 2
Mechanical
Material
ABS, Polycarbonate
Dimensions W x L x H
27 mm x 156 mm x 80 mm
Mounting plate
127mm x 68mm
Installation
Panel installation
Environmental conditions
Operative temperature
0 °C ... 55 °C
Storage Temperature
-20 °C ... +85 °C
Relative Humidity
5 % a 95 % no condensation
Electric isolation
Air clearance
According to IEC 60664-1
Pollution
According to IEC 61131-2
2
Protection
Rear protection
IP 20
Front protection
IP65
Attention
Install the device in a panel with no more than 55 °C.

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
8
3.1. Panel mount
3.1.1. Distance
System must be installed with a space for heat dissipation and cabling. Avoid
cabling superimposing to avoid EMC problems.
Figure 6A: Horizontal mounting
Figure 6B: Vertical mounting

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
9
4. TP1043 02 wiring
4.1. Connections
In the following figure see the wiring diagram.
Figure 7
Table 3
TP1043 02
Power Supply 24VDC
12÷36Vdc - 150mA (24Vdc)
Power Supply 24VAC
24Vac ±20% - 150mA
Micro-USB
2.0
Ethernet
Bit rate: 100Mbit/sec
Serial ouputs
RS485 Modbus half duplex (hardware configuration) or
CANopen
4.2. Power supply
4.2.1. Insulation
Device has no galvanic isolation between input, output and power supply.
4.2.2. System power supply
TP1043 02 has a 12÷36Vdc or 24Vac (see the model purchased) according to the
scheme in the figure. System is protected against reverse power supply.

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
10
4.2.3. Fuse
System has no internal fuse, so the use of an external 500mA fuse for the panel power
supply is recommended.
Figure 8
Attention
A wrong value for the power supply can cause a damage to the
device
4.3. ModBus wiring
ModBus on TP1043 02 is a 2 wire RS485 serial line, on the terminal board on pins:
Table 4
Pin
Signal
Description
3
GNDiso
2
D +
Linea +
1
D -
Linea -
Example of a wiring of a system composed by:
MPNC005
MPNC020
MPNC030
TP1043 02

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
11
Figure 9
4.4. CANOpen wiring
The CANopen interface on TP1043 02 must be connected to the terminal block on
the pins shown in the table.
Table 5
Pin
Signal
Description
3
GNDiso
2
CAN L
Linea -
1
CAN H
Linea +
Example of a wiring of a system composed by:
MPNC010
MPNC030
TP1043 02

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
12
3
4
CANOpen
GND
L
H
24Vdc/Vac
5
2
1
MPNC010
MPNC030
24Vdc
iso
Figure 10
5. Peripherals
5.1. USB
TP1043 02 has a Micro-USB 2.0 host for:
software update
data storage: datalogger
connect USB peripherals as printers, mouse, etc.
Specific connection of external peripherals are implemented on request.
5.2. Ethernet
TP1043 02 has a 10/100Mbit/s ethernet port with auto-configuration, the connection
cable between TP1043 02 and a personal computer can be either straight either cross.

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
13
6. HMI
To set the TP1043 02 is necessary to develop a software in QT Creator based on QT
libraries, custom-tailored on MECT operator panel.
A specific tutorial is furnished with the device.
The QT Creator suite software is available in Windows environment.
6.1. System variables
The system can use 5472 interchange variables between HMI and automation (at
maximum) which include:
internal variables, interchange variables on Modbus network, retentive variables.
The variables are defined by a software “Mect Suite”.
7. How to order
Other manuals for TP1043 02 series
1
Table of contents
Other Mect Control Panel manuals
Popular Control Panel manuals by other brands

Panasonic
Panasonic AK-HRP1000G operating guide

Engineering Incorporated
Engineering Incorporated PMA6000 Pilot's guide and operation manual

RIB
RIB K2 24V Assembly instructions

Snarkoon
Snarkoon Frontpanel VR manual

HEIDENHAIN
HEIDENHAIN TNC 620 user manual

Quest Engineering
Quest Engineering DEH 3000R Installation, operation and maintenance instructions