Meech 261v2 User manual

Model 261v2
Operating
Manual
Ion Nozzle


Products shown in this document may be covered by one or more patents, patents applied for
and/or registered designs and/or trade marks. For further information please refer to our Head
Oce or visit www.meech.com.
© Meech Static Eliminators Ltd., 26.10.2017
Contents
Introduction 3
Unpacking and Inspection 4
Installation 5
Technical Specication 7
Maintenance 8
Fault Finding 10
Repairs and Warranty 12
CE Approval 13
Health and Safety 13


3
Introduction
The Meech Model 261v2 Ion Nozzle has been designed to eectively eliminate
localised static charges which exist in the work area.

4
Unpacking and Inspection
The Model 261v2 Ion Nozzle has been carefully packed at the factory in a container
designed to protect it from accidental damage. Nevertheless, we recommend careful
examination of the carton and contents for any damage. If damage is evident, do not
destroy the carton or packing material and immediately notify the carrier of a possible
damage claim. Shipping claims must be made by the consignee to the delivering
carrier.
General
The Model 261v2 Ion Nozzle is a small, robust ionising nozzle. Available in several
versions it provides an ionised airow for cleaning and neutralising static charges.
It is powered by a Meech Model 233v3, 977CM or 977v3 Pulsed DC Controller. It is
suitable for industrial, electronic and cleanroom environments and is quick to install
and easy to use. The Model 261v2 features replaceable titanium emitters.
It is available in various versions with dierent inlet and outlet congurations. Drawings
of these versions are available from the Meech website.
A261V2-32 6mm Input, Nozzle outlet. Good for general
cleaning operations.
A261V2-32-1/4 ¼”bsp Inlet, ¼” bsp outlet. Inline nozzle.
A261V2-32-1/4OUT 6mm Input, ¼” bsp outlet. Inline nozzle.
A261V2-32-BULKHEAD 6mm Input, Bulkhead tting. For ducting and air
conveying applications.
A261V2-32-FLEX 6mm Input, Flexible outlet pipe. For sheet
separation and tight installations.
A261V2-32-FLEX-1/4 ¼”bsp Inlet, Flexible outlet pipe. For sheet
separation and tight installations.
A261V2-32-SLOT ¼”bsp Inlet, Slotted Cap. For sheet feeding on
presses.

5
Installation
The Model 261v2 should be connected to the 233v3, 977CM or 977v3 Pulsed DC
Controller. Connect each of the male plugs on the cable of the Model 261v2 to a
high voltage socket on the Pulsed DC Controller. In the case of a multiple nozzle
installations, use the appropriate pair of high voltage splitters.
Air Supply
Depending on which model of 261v2 is being used it may be installed with
compressed air or pumped air.

6
Compressed Air
Connect your air supply directly to the Model 261v2 using 6mm push t hose. A local
compressed air shut-o valve should be installed (not supplied). For most applications,
the compressed air supply should be regulated to 30 psi (2 bar). Maximum operating
pressure is 100psi (7 bar).
Pumped Air
Versions of the nozzle with ¼” bsp inputs can be used with low pressure pumped air.
Ensure that any ttings used have as side a bore as possible, to maximise the air-ow.
Interlocking of High Voltage
We recommend interlocking the state of the high voltage output to the running state
of the machine. This can be achieved by switching the power supply to the Pulsed
DC controller or by using the remote on/o input built into all Meech Pulsed DC
controllers. See the relevant operating manual for more information.
For Best Results
1. Keep the target area clear and free from obstructions to the ion ow.
2. Keep the work area clear of all static generative materials.
3. Use only approved static control grounding methods and material handling
equipment.
4. By properly using ionised air, all static potentials in the work area are greatly
reduced, even when humidity levels decrease.

7
Technical Specication
Model 261 Ion Nozzle
Body : PTFE
Length : 74 mm
Diameter : 32 mm
Weight : 0.06 kg ( Without bracket)
Max Air Pressure rating : 100 Psi( 7 bar),
Typical Pressure : 20 to 40Psi (1.5 to 3 Bar)
Noise level : 68 dBA ( 20 Psi at 1m)(1.5 bar)
Emitter Pins : machined titanium (7mm)
Decay time : 0.8 sec at 150mm at 30 Psi (2 bar)
(1000V to100V)
Ozone : Less than 0.01 ppm
Input Voltage : +/- 9kV DC Nominal
Ion balance : +/- 10V or better at set up
Calibration and Balance Verication
For critical ESD installations, balance verication should be checked in accordance
with the ESD protection Standard ANSI-EOS/ESD-S3.1-1991
Remember
It is important to verify calibration after any adjustments and before using your Ion
Nozzle in the presence of sensitive electronics.

8
Maintenance
Cleaning your Meech Ioniser
Ionisers require periodic cleaning. During normal operation, dirt will build-up on
the emitter pins and upon the body of the ioniser. This will cause a reduction in
performance.
Ionising nozzles may need their outlet cap to be removed to allow access to the pins.
They should be checked for any oil or water contamination that might indicate a poor
quality air supply that could cause permanent damage.
Typically, weekly cleaning is sucient. However, equipment used in some heavy
contamination areas, such as gravure printing or where plastic fumes are present, may
require daily cleaning.
Before cleaning, ensure that the equipment is switched o.
Emitter pins can be cleaned very eectively with a brush. A dry toothbrush is ideal.

9
Ionisers will need periodic wiping to clean grey deposits from the surface of the bar. A
cloth moistened with a small amount of IPA or methylated spirits is recommended.
If the pins are worn and require replacement, the pins should be removed using a
pair of round nose pliers and replacements tted. Replacement pins are available from
Meech, item code A-200-EMITP-10/1.0.
The exterior of the Ion Nozzle should be kept clean by wiping with a damp cloth.

Fault Finding
Tests must be completed by a qualied electrical engineer.
If in doubt contact Meech head oce or your local distributor.
CAUTION: Whilst no danger to personnel exists, it is essential than any high
voltage ionising equipment makes no contact with water or water based uids.
Should such an event occur, disconnect immediately and return equipment to
Meech for water damage assessment.
Cable Plugs
Please note that, on leaving the factory, the brass ends of the cable plugs are
congured to a standard size for tment into the power sockets of the Pulsed DC
Controller. Meech has found that occasionally during transportation and handling the
ends of the plugs can become slightly mis-shaped which may cause diculty with their
location into the power sockets.
10

If you nd this to be the case, then (1) if the plugs are too tight, you should lightly
pinch together the two halves of the brass end of the plug with a pair of pliers, or (2) if
the plugs are too loose, you should gently open out the slot in the brass end with the
blade of a screw-driver or knife.
11

Repairs and Warranty
Your Ion Nozzle is warranted by Meech Static Eliminators Ltd to the original purchaser
against defects in material and workmanship for one year after purchase. Should any
malfunction occur, please return the Ion Nozzle directly to Meech or to your distributor.
All products returned to the factory MUST be accompanied by a return authorisation
number and must be shipped prepaid. Meech Static Eliminators Ltd. liability under this
warranty is limited to replacing or repairing any unit returned by the purchaser that has
not been subject to misuse, neglect, repair, alteration or accident. In no event shall
Meech Static Eliminators Ltd be liable for collateral or consequential damages.
For prompt service, ship the unit to the factory with the return authorisation number
shown clearly on the label. Be sure it is well packed in a sturdy carton with shock
absorbing material. Include a note stating the nature of the problem as specically as
possible, and also include instructions for returning the Ion Nozzle to you. Meech will
pay one-way return surface shipping costs on any repairs covered under the warranty.
Field repairs should not be undertaken during the warranty period. Repair attempts by
unqualied personnel will invalidate the warranty.
Important
Your Ion Nozzle has been designed to minimise eects of localised static charges.
If your processing involves generation of considerable static charges, however, you
may need more powerful equipment. Meech Static Eliminators Ltd manufactures a
complete range of Ionising Blowers, Air Guns, Bars and overhead room systems to
meet all your Static Elimination requirements.
12

CE Approval
An EC Declaration of Conformity for this product exists in respect of the Low Voltage
Directive:72/23/EEC (“LVD”) & Electromagnetic Compatibility Directive: 89/336/EEC
(“EMCD”)
Health and Safety
Emission of Ozone: Considerably below international standard of 0.1ppm.
13

©Meech Stac Eliminators Ltd 2017 www.meech.com
Meech Internaonal
2 Network Point
Range Road, Witney
OX29 0YN, UK
Tel: +44 (0)1993 706700
Fax: +44 (0)1993 776977
email: [email protected]
Meech Stac Eliminators
(Shanghai) Co. Ltd
7G, 7F, LP Tower
#25 Xiangfeng Road
201103 Shanghai
China
Tel: +86 400 820 0102
Fax: +86 21 6405 7736
email: [email protected]
Meech Stac Eliminators USA Inc
2915 Newpark Drive
Norton, OH 44203
USA
Tel: +1 330 564 2000 / 1 800 232 4210
Fax: +1 330 564 2005
email: [email protected]
Meech Shavotech
29/2, Kharadi
O Pune-Nagar Road
On Old Kharadi Mundhwa Road
Pune : 411014 , Maharashtra
India
Tel: +91 (0)703 093 8211 / +91 (0)741 000 4817
Fax: +91 (080) 28395963
email: [email protected]
Meech Elektrostak SA
Kaiserbaracke 166
B-4780 St.Vith
Belgium
Tel.: +49 (0)6555 3733 399
+32 (0)80 670 204
Fax: +32 (0)80 862 821
email: [email protected]
Meech Internaonal
(Singapore) Pte. Ltd.
7 Temasek Boulevard
12 - 07 Suntec Tower One
Singapore
Singapore
038987
Tel: +65 65918859
email: [email protected]
Meech CE
Gábor László utca 2
Budapest 1041
Hungary
Tel: +36 1 7977039
+36 30 2803334
email: [email protected]
This manual suits for next models
1
Table of contents
Other Meech Control Unit manuals
Popular Control Unit manuals by other brands

nilan
nilan Compact P Polar EK 6 kW CTS 700 user manual

Spectrum Controls
Spectrum Controls 1756-CTR8 user manual

Edwards
Edwards 3-24R Installation sheet

Miller-Leaman
Miller-Leaman ATF Series Operation instructions

Rockwell Automation
Rockwell Automation Allen-Bradley 1746-HSCE user manual

MORDOMUS
MORDOMUS iThink manual