MESSKO D1272AT User manual

www.messko.de
数字显示器 / Digital Indicator D1272AT
使用说明书 / Operating Instructions BA2082
D1272AT
Messko

目录
/ Contents
目录
Contents
Messko
1
安全
...........…………………………..................... 4
1.1
安全须知
.........………………………................... 4
1.2
指定用途
........……………………....................... 4
1.3
设备操作重要说明
.......………………..................4
2
产品规格
..........…………………………............... 5
2.1
操作
............………………................................ 5
2.2
输入
............…………............ ......................... 6
2.3
最小
/
最大存储
...………………........................... 6
2.4
报警触头
ALM1
和
ALM2 (
选择件
) ...……..........6
2.5
模拟输出
(
选择件
) ........……………….............. 7
3
安装
...........………………................................ 7
4
电气连接
.........…………………….................... 8
4.1
电压
............………………………..................... 8
4.2
传感器输入
...........……………….................. 8
4.3
继电器输出报警
1
和报警
2 (
选择件
) ..... …...... 9
4.4
模拟输出
(
选择件
) .......………….....................9
5
技术参数
..........………………….................... 9
6
附录
......……………………………………........10
6.1 Pt100
传感器连接
......…………………............ 10
6.2 4-20mA
有源传感器连接
...……..................... 11
6.3 4-20mA
无源传感器连接
....………………........ 11
1 Safety .....…………......................................... 4
1.1 Safety instructions .........……………................ 4
1.2 Specified application .......………..................... 4
1.3 Important notes on equipment operation.…….. 4
2 Product Specification.....………………….......... 5
2.1 Operation ...........…….................................... 5
2.2 Input ...............………..................................... 6
2.3 Min./max. Memory .............………................... 6
2.4 Alarm contacts ALM1 and ALM2 (optional) …... 6
2.5 Analog output (optional) .....………………......... 7
3 Installation ......…………………........................ 7
4 Electrical Connection.....………………….......... 8
4.1 Voltage supply ............………………................ 8
4.2 Sensor input ............………………................... 8
4.3 Relay outputs alarm 1 and alarm 2 (optional) ... 9
4.4 Analog output (optional) .........…….................. 9
5 Technical Data ...........…………………............ 9
6 Appendix.....……………………........................ 10
6.1 Connection of Pt100 sensor ......…….............. 10
6.2 Connection of active 4-20mA sensor …............11
6.3 Connection of passive 4-20mA sensor ..…...... 11
提示
本说明书中的数据可能会和交货的装置稍有差
异。
我方保留进行更改的权利,恕不另行通知。
NOTE
Data contained herein may differ in details from the
equipment delivered.
We reserve the right to make alterations without notice.
请保留本说明书以备日后参考
Please keep this manual for future reference!
BA 20820105 3

1
安全
/ Safety
1
安全
1.1
安全须知
从事本设备的安装、试运行、运行的人员必须:
-
具有合格的专业资格
-
严格遵守本使用说明书
违章操作或错误使用可能导致
-
严重的或致命的伤害
-
损坏本设备或用户的其它设备
-
降低本设备的效能
在安全须知上,本说明书采用如下三种形式强调各种重要
事项:
1 Safety
1.1 Safety instructions
All personnel involved in installation, commissioning or
operation of this equipment must:
- be suitably qualified and
-
strictly observe these operating
instructions.
Improper operation or misuse can lead to
- serious or fatal injury,
- damage to the equipment and other property of the
user
- a reduction in the efficiency of the equipment.
Safety instructions in this manual are presented in three
differ- rent forms to emphasize important information.
警告
这是对危及性命和健康的危险的警示符号,忽视这
种警示可能导致严重的或致命的伤害。
WARNING
This information indicates particular danger to life and
health. Disregarding such a warning can lead to
serious or fatal injury.
注意
这是对本设备或用户其他财产有一定危险的警示,
不排除严重的或致命的伤害。
CAUTION
This information indicates particular danger to the
equipment or other property of the user. Serious or
fatal injury cannot be excluded.
提示
这是对某些事项的重要说明。
NOTE
These notes give important information on a certain
issue.
1.2
指定用途
D1272AT
数字显示器用于显示过程值如温度或油位。
调试仪表前,务必阅读并查看铭牌上和操作使用说明书
上的操作限定值。
1.3
设备操作的重要提示
用户必须遵守国家健康及安全规章。
特别要强调的是,如果工作是在带电的部件(直接接触会
触电)上进行,那么,只有在这些部件断电后,或者对它
们进行了妥善的保护,工作人员直接接触不到时,这些工
作才可以进行。
1.2 Specified application
The D1272AT digital indicator is used to indicate
process values such as temperature or oil level, for
example.
It is important to read and observe the limit values for
operation indicated on the nameplate and in the
operating instructions prior to commissioning the device.
1.3 Important notes on equipment operation
The user is obliged to comply with the national health
and safety regulations.
It is especially emphasized that works performed to live,
i.e. dangerous-contact components, are permissible
only while these components are either de-energized or
protected against direct contact.
4 BA 20820105

2
产品规格
/ Product Specification
2
产品规格
2 Product Specification
Messko
D1272AT
数字显示器是易于使用的装置,用于显示标准
The D1272AT digital indicator is an easy-to-use device
Pt100
或
4-20mA
信号。正常操作时,测量值显示在四
for the indication of standard Pt100 or 4-20mA signals.
位
LCD
显示器上。
During normal operation, the measured value is shown
on the four-position LCD display.
四位显示
/
Four position display
测量装置
/ Unit of measure
报警状态
/
Alarm status
最小
/
最大显示
Min./max. display
图
1 / Fig. 1
„
向上
UP“
和
„
向下
down“
键
„Up“ and down“ keys
„Enter“
键
„Enter“ key
2.1
操作
Enter
输入键可在下列菜单之间跳过顺序使用
正常操作时:显示测量值(过程值)
最大值显示。重置时,按住
„Up“
或
„Down“
键,直到显示出四个
BARS
。
最小值显示:重置时,按住
„Up“
或
„Down““
键,直到显示出四个
BARS
。
转换点报警
1
。转换点可以用
„Up“
或
„Down“
键设定。
转换点报警
2
。转换点可以用
„Up“
或
r „Down“
键设定。
当报警触头激活时,菜单中会出现
此显示。否则,不会选择此菜单。
2.1 Operation
The Enter key can be used to jump sequentially
between the following menus.
Normal operation: Indication of the
measured value (process value)
Indication of the Max. value. To reset, keep
the„Up“ or „Down“ key pressed until 4 bars
appear on the display.
Indication of the Min. value. To reset, keep
the„Up“ or „Down“ key pressed until 4 bars
appear on the display.
Switching point Alarm 1. The switching
point can be set with the „Up“ or
„Down“ key.
Switching point Alarm 2. The switching
point can be set with the „Up“ or
„Down“ key.
When an alarm contact is active, this is
indicated in this menu. Otherwise, this
menu cannot be selected.
BA 20820105 5

2
产品规格
/ Product Specification
2.2
输入
Pt100
或
4-20mA
信号可按照装置的设计连接到
D1272AT
的输入上。
已控制输入的范围,如出现故障,会出现下列信号:
•
输入传感器故障或未连接
•
低于输入范围(低)
•
超过输入范围
(高)
4-20mA
输入可以使用
有源
或
无源
信号。
有源信号:
传感器
/
信号转换器已通电,不再需要外部任
何额外的电源(如
MTO/TT
油位显示器或
TT-PWM60
温度
传感器)。
无源信号:
传感器
/
信号转换器需要外部电源(如
MT-
ST160SK/TT
指针式温度计)。信号转换器电源可选择在
工厂通过接线端子
10
和
12
配置(见铭牌)。该电源可为
传感器
/
信号转换器提供大约
24VDC
的电压。
2.3
最小
/
最大存储
末次重置后会存储下最小测量值和最大测量值。可用前
面的键调出这些值。见第
2.1
章
2.4
报警触头
ALM1
和
ALM2 (
选择件
)
D1272AT
数字式显示器可选择配双继电器(见铭牌)。
2N/0
触头的转换点可设定不同的限定值并可以用于发出
报警信号或类似信号。超过设定限定值时,特别触头关
闭(报警
1
或报警
2
),相应的状态
LED
(
ALM1
和
ALM2
)会闪烁。继电器连接在后面。见
4.3.
章。
限定值可按
2.1
章所述设定。
返回控制滋滞为
1K
。
2.2 Input
A Pt100 or 4-20mA signal can be connected to the input
of the D1272AT in accordance with the device design
(see nameplate).
The input range is monitored and, in case of error, the
followingmessages are output:
•
The input sensor is defective or not
connected.
•
The input range has been passed below
(Low).
•
The input range has been exceeded
(High).
The 4-20mA input can be used with an
active
or a
passive
signal.
Active signal:
The sensor/signal transducer is already
powered and does not require any additional power from
the outside (e.g., oil level indicator MT0/TT or
temperature transmitter TT-PWM60).
Passive signal:
The sensor/signal transducer requires
external power (e.g., pointer thermometer MT-
ST160SK/TT). A signal transducer power supply can
be configured here optionally at the factory on terminals
10 and 12 (see nameplate). This power supply provides
a voltage of approx. 24 V DC for the sensor/signal
transducer.
2.3 Min- / Max-memory
The minimum measured value and the maximum
measured value since the last reset are stored. They
can be called with keys on the front. See chap. 2.1.
2.4 Alarm contacts ALM1 and ALM2 (optional)
The digital indicator D1272AT can be optionally
equipped with a double relay (see nameplate). The
switching points of the 2 N/O contacts can be set to
different limit values and can be used to generate an
alarm message or similar. When the set limit values
exceeded, the particular contact closes (alarm 1 or
alarm 2) and the related status LED (ALM1 and ALM2)
flashes. The relays are connected on the back. See
chap. 4.3.
The limit values can be set as described in chap. 2.1.
The return control hysteretic is 1K.
6 BA 20820105

10
(0.4")
-0,0
3
安装
/ Installation
Messko
2.5
模拟输出(选择件)
D1272AT
数字式显示器可选择配备模拟输入用于过程值
的远距离传输。请见铭牌。下列标准信号可在工厂设
定:
•
4 - 20mA
•
0 - 20mA
•
0 - 5V
•
0 - 10V
其它输出信号可用信号转换器补充。
2.5 Analog output (optional)
The D1272AT digital indicator can be optionally
equipped with an analog output for the remote
transmission of the process value. See nameplate. The
following standard signals can be set at the factory:
•
4 - 20mA
•
0 - 20mA
•
0 - 5V
•
0 - 10V
Other output signals can be implemented with a signal
converter.
3
安装
3 Installation
注意
必须严格遵守本使用说明书要求的安装条件。
CAUTION
The installation conditions demanded by this
operating manual must be strictly complied with.
D1272AT
数字式显示器可安装到壁厚
6
毫米的控制板上。
控制板的尺寸切口图,见图
2
。
The D1272AT digital indicator can be installed in control
panels with a wall thickness of up to 6 mm. For the
dimensions of the control panel cutout, see figure 2.
控制板切口图
Control panel cutout
92
+0,5
(3.62")
96 (3.8")
控制板密封
Control panel
sealing
支撑架
/ Holder frame
100 (3.94")
图
2 / Fig. 2
控制板
/ Control panel
BA 20820105 7
操作者前方
Operator front
48 (1.9")

4
电气连接
/ Electrical Connection
按下列步骤安装本装置:
•
将
D1272AT
数字显示器滑进控制板切口内并确定指
示器的最后定位为前面。然后轻按指示器使其靠着
控制板。检查确保控制板密封正确定位。
•
从后面开始,将支撑架滑过将置至其接触到控制板
的后面。支撑架上和下的支撑齿会卡进装置的支撑
格。支撑架的弹簧必须紧紧抵着控制板的后面。
装置安装好后就可以连接了。
4
电气连接
Proceed as follows to install the device:
• Slide the D1272AT digital indicator into the control
panel cutout so that the final location of the
indicator is in front. Then lightly press it against the
control panel. Check to make sure that the control
panel seal is positioned correctly.
• Starting from the back, slide the holder frame over
the device until it touches the back of the control
panel. The holder teeth on the top and bottom of the
holder frame will then snap into the holder grid of
the devices. The springs of the holder frame must
be pressed firmly against the back of the control
panel.
After the device has been installed, it can be connected.
4 Electrical Connection
注意
只有经过国家适当的安全规程培训过的合格的、熟
练人员才能进行电气连接。
CAUTION
The electrical connection may only be performed by
qualified, trained personnel who have been
instructed in the applicable safety regulations of the
particular country.
对于
D1272AT
数字显示器的连接,我们建议使用开口式
电缆终端进行
M3
螺纹式连接。按照附录中的连接图进行
连接。
4.1
电压
通过
13
和
14
号接线端子进行连接。电压
: 90-264VAC
±1%, 50/60Hz,
最大
7,5VA
4.2
传感器输入
连接输入信号时,应确保装置的测量范围符合并遵守电
路的最大载荷。
Pt100:
Pt100
输入设计用于连接
Pt100
传感器与
3
导线技术。通
过接线端子
1
和
2
连接。均衡线连接到接线端子
3
上。如果
连接
2
导线传感器,必须先将接线端子
2
和
3
短路。见图
3
。
4-20mA,
有源传感器
如果
4-20mA
传感器为有源连接(即无需外来电压),
将传感器连接到接线端子
1
(
-
)和接线端子
4
(
+
)。见
图
4
。
For the connection of the D1272AT digital indicator, we
recommend using open cable shoes for M3 screw-type
connections. Follow the connection diagrams in the
appendix.
4.1 Voltage supply
The connection is performed via the connection
terminals 13 and14. Voltage: 90 - 264 V AC +1%, 50/60
Hz, max. of 7.5 VA.
4.2 Sensor input
When connecting the input signal, make sure that the
measuring ranges of the devices agree and adhere to
the maximum load of the circuit.
Pt100:
The Pt100 input is designed for the connection of a
Pt100 sensor with 3-conductor technology. The
connection is made via the terminals 1 and 2. The
equalizing line is connected to terminal 3.If a 2-
conductor sensor is to be connected, terminals 2 and 3
must be short-circuited. See figure 3.
4-20mA, active sensor:
When the 4-20mA sensor to be connected is active (i.e.,
no further outside voltage is needed), connect the
sensor to terminal 1 (-) and terminal 4 (+). See figure 4.
8 BA 20820105

5
技术参数
/ Technical Data
Messko
4-20mA,
无源传感器
D1272AT
数字式传感器配有驱动传感器
/
信号转换
器的模块时(见铭牌),无源传感器(如
MT-
ST160/TT
指针式温度仪)便可由此驱动。
传感器电源在接线端子
10
(
-
)和接线端子
12
(
+
)上约为
24VDC
。
传感器连接时,电压必须形成回路。为此,跳接接
线端子
1
和
10
并将输入传感器连接至接线端子
4
(
-
)和
12
(
+
)。见图
5
。
4.3
继电器输出报警
1
和报警
2
(选择件)
继电器输出设计为双继电器(即
2N/O
触头在接线端子
23
上有共同的势能)。
根据用途将继电器连接到接线端子
22
和
23
或
24
和
23
。
4.4
模拟输出(选择件)
模拟输出
`
连接到接线端子
21
(
+
)和
19
(
-
)上。确
保连接装置的测量范围是相同的并与电路的最大载
荷相符。
4-20mA, passiver Sensor:
When the D1272AT digital indicator is equipped with a
module for powering a sensor/signal transducer (see
nameplate),a passive sensor (e.g., pointer thermometer
MT-ST160/TT) can be powered with this.
The sensor power of approx. 24 V DC is available on
terminal 10(-) and terminal 12 (+).
The voltage must be looped in when the sensor is
connected. For this, jumper terminals 1 and 10 and
connect the input sensor to terminals 4 (-) and 12 (+).
See figure 5.
4.3 Relay outputs alarm1 and alarm2 (optional)
The relay outputs are designed as double relay (i.e., the
two N/O contacts have a common potential on terminal
23).
Connect the relay to terminals 22 and 23 or 24 and 23
depending on your application.
4.4 Analog output (optional)
The analog output is connected to terminal 21 (+) and 19
(-). Make sure that the measuring range of the connected
devices isthe same and the maximum load of the circuit
is adhered to.
注意
本使用说明书上的信号适用于标准设备。如使
用特殊设备,请遵守铭牌上和订单上的信号。
CAUTION
The information in these operating instructions
applies to standard devices. When special devices
are used, adhere to the information on the nameplate
and the order.
5
技术参数
输入
供应电压:
100-260VAC, 50/60Hz
或
100-
260VDC
耗电:
最大
7,5VA
输入信号:
Pt100
信号
符合
IEC751, 4-20mA
有
源或无源信号
测量范围符合铭牌
温度范围
运行:
0°C-+55°C
存储:
-20°C-+80°C
输出(选择件)
电流输出:
4-20mA
或
0-20mA,
最大载荷
250W
电压输出:
0-5V
或
0-10V,
最小载荷
2Kw
传感器电源(选择件)
输出电压:
约
24VDC (
无载荷约
27VDC)
输出载荷:
最小
910W (20VDC
时为
22mA)
5 Technical Data
Input
Supply voltage: 100-260VAC, 50/60Hz or 100-
260VDC Power consumption: max. 7,5VA
Input signal: Pt100-signal in accordance with IEC751,
4-20mA signal active or passive,
measuring range as per
nameplate
Temperature range
Operation: 0°C - +55°C
Storage: -20°C - +80°C
Output (optional)
Current output: 4-20mA or 0-20mA,
max. load of 250W
Voltage output: 0-5V or 0-10V, min.
load of 2kW
Sensor power (optional)
Output voltge: Approx. 24VDC (no-load: approx.
7VDC) Output load: Min. of 910W (22mA at 20VDC)
BA 20820105 9

6
附录
/ Appendix
继电器(选择件)
设计:
普通连接的
SPST
双继电器
触头额定值:
最大
2A
和
240VAC,
欧姆载荷
运行循环:
最大载荷
>200.000
绝缘:
与所有其它输入和输出绝缘
环境测试
认证:
CE, UL, ULC
EMV
一致性:
认证符合
EN61326
防护等级:
IP65 (IP20
控制板后
)
符合
IEC 60529
外壳
尺寸:
深
100mm
控制板后
操作者前
96 x 48 (B x H)
接线端子:
螺纹式接线端子
重量:
最大
210
克
6
附录
6.1 Pt100
传感器连接
Relay (optional)
Design: SPST double relay with
common connection
Contact rating: Max. of 2A and 240VAC, ohmic load
Operating cycles: >200.000 for max. load
Insulation: Insulated from all other inputs
and outputs
Environmental tests
Certifications: CE, UL, ULC
EMC compatibility:Certified in accordance with EN 61326
Protection rating: IP65 (IP20 behind the control panel)
in accordance with IEC 60529
Housing
Dimensions: Depth: 100 mm behind control panel
Operator front: 96 x 48 (W x H)
Terminals: Screw-type terminals
Weight: Max. of 210 g
6 Appendix
6.1 Connection of Pt100 Sensor
Pt100 (RTD)
+ -
模拟
输出
N L
电源
100-260V AC/DC
图
3 / Fig. 3
10 BA 20820105

6
附录
/ Appendix
Messko
6.2 4-20mA
有源传感器连接
Connection of active 4-20mA sensor
4-20mA
有源输入
图
4 / Fig. 4
模拟
输出
电源
100-260V AC/DC
6.3 4-20mA
无源传感器连接
Connection of passive 4-20mA sensor
4-20mA
无源输入
图
5 / Fig. 5
模拟
输出
电源
100-260V AC/DC
BA 20820105 11
+ - N L
+ - N L
+ -
- +
- +
- +
Other manuals for D1272AT
1
Table of contents
Other MESSKO Measuring Instrument manuals