Single resistor application Desired value has to be set by rotating
the appropriate knobs of rotary switches. Each knob contain
multiplier dial of marked range.
Example: to set resistance of 2850 kW select 2 x 1M,
8 x 100k, 5 x 10k and rest to 0. Banana plugs must be connected
into sockets that cover at least all positions different to 0.
Split chains If e.g. knob x 1k selects position, the MA 2115 is split
into high resistance decade part in range (0 – 9990 k) W and low
resistance decade part in range (0 – 999) W. Use appropriate
sockets.
Voltage divider Simple voltage divider can also be configured for
test purpose. Example: voltage divider with 1000:1 ratio and input
resistance of 2 MW has to be realized. Set 2 x 1M, 2 x 1k and rest to
0. Input voltage is connected between most left sockets and socket
in bottom right corner and for output voltage use socket between x
10 k and x 1 k and the same socket on right corner. If voltage
connected to divider is higher than 50 V connect PE into green
socket.
MAINTENANCE
Inspection To maintain operator safety and ensure reliability of MA
2115 it is good practice to inspect it on a regular basis. Check that the
enclosure is without defects such as scratches or breaks. If any defect
is found please consult repair centre, distributor and/or manufacturer.
Cleaning Use a soft cloth slightly moistened with soapy water or
spirit to clean the surface of the instrument and leave the instrument
to dry totally before using it.
Notes!
• Do not use liquids based on petrol or hydrocarbons!
• Do not spill cleaning liquid over the instrument!
Calibration It is essential, that MA 2115 be regularly calibrated. We
recommend an annual calibration.
Service Repairs under or out of warranty time: Please contact your
distributor for further information.
Resistance
MA 2115
MA 2115S
Decade
Instruction Manual
Code No. 20 750 678
Measuring and Regulation Equipment
Manufacturer
Ljubljanska 77, SI 1354 Horjul
Tel.: +386 1 7558 200; Fax: +386 1 7549 226
http://www.metrel.si; E-mail: [email protected]
Single resistor application Desired value has to be set by rotating
the appropriate knobs of rotary switches. Each knob contain
multiplier dial of marked range.
Example: to set resistance of 2850 kW select 2 x 1M,
8 x 100k, 5 x 10k and rest to 0. Banana plugs must be connected
into sockets that cover at least all positions different to 0.
Split chains If e.g. knob x 1k selects position, the MA 2115 is split
into high resistance decade part in range (0 – 9990 k) W and low
resistance decade part in range (0 – 999) W. Use appropriate
sockets.
Voltage divider Simple voltage divider can also be configured for
test purpose. Example: voltage divider with 1000:1 ratio and input
resistance of 2 MW has to be realized. Set 2 x 1M, 2 x 1k and rest to
0. Input voltage is connected between most left sockets and socket
in bottom right corner and for output voltage use socket between x
10 k and x 1 k and the same socket on right corner. If voltage
connected to divider is higher than 50 V connect PE into green
socket.
MAINTENANCE
Inspection To maintain operator safety and ensure reliability of MA
2115 it is good practice to inspect it on a regular basis. Check that the
enclosure is without defects such as scratches or breaks. If any defect
is found please consult repair centre, distributor and/or manufacturer.
Cleaning Use a soft cloth slightly moistened with soapy water or
spirit to clean the surface of the instrument and leave the instrument
to dry totally before using it.
Notes!
• Do not use liquids based on petrol or hydrocarbons!
• Do not spill cleaning liquid over the instrument!
Calibration It is essential, that MA 2115 be regularly calibrated. We
recommend an annual calibration.
Service Repairs under or out of warranty time: Please contact your
distributor for further information.
23
Mark on your equipment certifies that this equipment meets
the requirements of the EU (European Union) concerning
safety and electromagnetic compatibility regulations.
Producer:
METREL d.d.
Ljubljanska cesta 77
SI-1354 Horjul
Tel.: +386 1 75 58 200
Fax: +386 1 75 49 226
E-mail: [email protected]
Http://www.metrel.si
© 2003, 2005 Metrel
Distributor:
No part of this publication may be reproduced or utilised in any form
or by any means without permission in writing from METREL.
WARNINGS
• If the Resistance decade is used in a manner not speci- fied
in this Users Manual, the protection provided by the
equipment may be impaired!
• Do not use the Resistance decade if any damage is no-ticed!
• If the voltage of circuit connected to the Resistance de-cade
is higher than safety level its metallic enclosure must be
connected to PE (ground) terminal of circuit!
• Do not exceed ratings marked on front plate!
• MA 2115 does not contain any user replaceable compo-nents.
TECHNICAL DATA
Resistance range:
- standard: 0 to 9 999 999 W
- optional on request: 7 decades with possible
extension to 9 x 1 MW and/or 9 x 0.1 W
Accuracy:
- individual decade unit : ± 1% + 0.08 W
- 9 x 0.1 W option: ± 2 % + 0.08 W
- overall: ± 1% + 0.4 W
Maximum ratings:
- continuous power dissipation: 1 W / resistor
- voltage / current: marked on front plate
- working voltage to case: 500 V d.c. / a.c. rms
Dimensions (w × h × d): 267 × 89 × 97 mm
Weight: 0,8 kg
Protection classification: Class I
Over-voltage category: CAT III 300 V
Pollution degree: 2
Working temperature range: (0 to 40) °C
Storage temperature range: -10 °C to 80 °C
Max. humidity: 85 % RH (0 to 40) °C
APPLICATION HINTS
In general always predict and set required value before connection
into circuit and/or turning power on of it to avoid destructive short
circuit currents.
GENERAL
MA 2115 Resistance Decade is intended for all application areas
where variable resistances selected by hand are required. It is
passive electric device housed in metallic case. It consists of 7
decades with each of its setting rotary switch with range multiplier
from 0 to 9, and. Safety F 4 mm sockets are connected to each
resistance chain that it could be individually accessible. It is also
possible to split resistance chain into two or more independent
insulated groups by selection of rotary switch position.
23
Mark on your equipment certifies that this equipment meets
the requirements of the EU (European Union) concerning
safety and electromagnetic compatibility regulations.
Producer:
METREL d.d.
Ljubljanska cesta 77
SI-1354 Horjul
Tel.: +386 1 75 58 200
Fax: +386 1 75 49 226
E-mail: [email protected]
Http://www.metrel.si
© 2003, 2005 Metrel
Distributor:
No part of this publication may be reproduced or utilised in any form
or by any means without permission in writing from METREL.
WARNINGS
• If the Resistance decade is used in a manner not speci- fied
in this Users Manual, the protection provided by the
equipment may be impaired!
• Do not use the Resistance decade if any damage is no-ticed!
• If the voltage of circuit connected to the Resistance de-cade
is higher than safety level its metallic enclosure must be
connected to PE (ground) terminal of circuit!
• Do not exceed ratings marked on front plate!
• MA 2115 does not contain any user replaceable compo-nents.
TECHNICAL DATA
Resistance range:
- standard: 0 to 9 999 999 W
- optional on request: 7 decades with possible
extension to 9 x 1 MW and/or 9 x 0.1 W
Accuracy:
- individual decade unit : ± 1% + 0.08 W
- 9 x 0.1 W option: ± 2 % + 0.08 W
- overall: ± 1% + 0.4 W
Maximum ratings:
- continuous power dissipation: 1 W / resistor
- voltage / current: marked on front plate
- working voltage to case: 500 V d.c. / a.c. rms
Dimensions (w × h × d): 267 × 89 × 97 mm
Weight: 0,8 kg
Protection classification: Class I
Over-voltage category: CAT III 300 V
Pollution degree: 2
Working temperature range: (0 to 40) °C
Storage temperature range: -10 °C to 80 °C
Max. humidity: 85 % RH (0 to 40) °C
APPLICATION HINTS
In general always predict and set required value before connection
into circuit and/or turning power on of it to avoid destructive short
circuit currents.
GENERAL
MA 2115 Resistance Decade is intended for all application areas
where variable resistances selected by hand are required. It is
passive electric device housed in metallic case. It consists of 7
decades with each of its setting rotary switch with range multiplier
from 0 to 9, and . Safety F 4 mm sockets are connected to each
resistance chain that it could be individually accessible. It is also
possible to split resistance chain into two or more independent
insulated groups by selection of rotary switch position.

This manual suits for next models

1

Other METREL Measuring Instrument manuals

METREL TeraOhmLT 10kV User manual

METREL

METREL TeraOhmLT 10kV User manual

METREL Instaltest 61557 MI 2087 User manual

METREL

METREL Instaltest 61557 MI 2087 User manual

METREL CE MultiTesterXA MI 3394 User manual

METREL

METREL CE MultiTesterXA MI 3394 User manual

METREL A 1783 User manual

METREL

METREL A 1783 User manual

METREL MD 9225 User manual

METREL

METREL MD 9225 User manual

METREL MD 9235 User manual

METREL

METREL MD 9235 User manual

METREL MI 3205 User manual

METREL

METREL MI 3205 User manual

METREL MI 3144 Euro Z 800 V User manual

METREL

METREL MI 3144 Euro Z 800 V User manual

METREL MI 3290 User manual

METREL

METREL MI 3290 User manual

METREL A 1018 User manual

METREL

METREL A 1018 User manual

METREL MD 9272 User manual

METREL

METREL MD 9272 User manual

METREL EurotestCOMBO MI 3125 User manual

METREL

METREL EurotestCOMBO MI 3125 User manual

METREL A 1501 User manual

METREL

METREL A 1501 User manual

METREL MI 3102 Manual

METREL

METREL MI 3102 Manual

METREL A 1179 User manual

METREL

METREL A 1179 User manual

METREL DeltaGT MI 3309 User manual

METREL

METREL DeltaGT MI 3309 User manual

METREL power master MI 2892 User manual

METREL

METREL power master MI 2892 User manual

METREL A1199 User manual

METREL

METREL A1199 User manual

METREL EurotestXE MI 3102H User manual

METREL

METREL EurotestXE MI 3102H User manual

METREL MI 3295 User manual

METREL

METREL MI 3295 User manual

METREL GammaGT MI 3311 User manual

METREL

METREL GammaGT MI 3311 User manual

METREL SmarTEC User manual

METREL

METREL SmarTEC User manual

METREL MD 126 User manual

METREL

METREL MD 126 User manual

METREL MI 3103 User manual

METREL

METREL MI 3103 User manual

Popular Measuring Instrument manuals by other brands

Martini Instruments MI 408 user manual

Martini Instruments

Martini Instruments MI 408 user manual

PCB Piezotronics 338C04 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 338C04 Installation and operating manual

Zoetis AlphaTRAK Instructions for use

Zoetis

Zoetis AlphaTRAK Instructions for use

LARSEN & TOUBRO LIMITED, MYSORE WORKS ER300P-PRIDE manual

LARSEN & TOUBRO LIMITED, MYSORE WORKS

LARSEN & TOUBRO LIMITED, MYSORE WORKS ER300P-PRIDE manual

Vivax Metrotech HL 6000 Operation manual

Vivax Metrotech

Vivax Metrotech HL 6000 Operation manual

LANDTEC GEOTECH DIVEAIR 2 operating manual

LANDTEC

LANDTEC GEOTECH DIVEAIR 2 operating manual

GW Instek GSP-730 user manual

GW Instek

GW Instek GSP-730 user manual

FLIR EXTECH HDV-WTX1 Product sheet

FLIR

FLIR EXTECH HDV-WTX1 Product sheet

Arizona Instrument JEROME J405 Operation manual

Arizona Instrument

Arizona Instrument JEROME J405 Operation manual

Koehler K2269X Operation and instruction manual

Koehler

Koehler K2269X Operation and instruction manual

Photonic UV254 GO! instruction manual

Photonic

Photonic UV254 GO! instruction manual

PCE Health and Fitness N24 user manual

PCE Health and Fitness

PCE Health and Fitness N24 user manual

Kusam-meco KM 3961 Operation manual

Kusam-meco

Kusam-meco KM 3961 Operation manual

Kapro 895 Prolaser All-Lines user manual

Kapro

Kapro 895 Prolaser All-Lines user manual

Endress+Hauser UniFit CPA 441 operating instructions

Endress+Hauser

Endress+Hauser UniFit CPA 441 operating instructions

Parker Racor RK30880E Instruction

Parker

Parker Racor RK30880E Instruction

ELCART PAGINA 4 DI 6 manual

ELCART

ELCART PAGINA 4 DI 6 manual

Instrutech The Hornet IGM402 user manual

Instrutech

Instrutech The Hornet IGM402 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.