Metsys ML3 User manual

METSYS ML2/3 LINE LASER OPERATTING MANUAL
Application/
Features
ML2
ML2P
ML2PG
ML3
ML3G
Green LD
Visibility Max
Drop Ceiling
Floor/ Tiling/
Door & Window
Leveling
Height Transfer
Point Transfer
Square
Layout
Pulse; / Power
saving Model
Slope Application
ML2/ 2P/2PG Product Overview
1. Laser Switch button
2. Pulse button
3. LED indicator
4. Laser Horizontal port
5. Laser Vertical port
6. Plumbing Dots port
7. Pendulum/Transit Lock
8. 1/4” & 5/8 ‘’ threaded mount
9. Battery cover
10. Main switch Button

METSYS ML2/3 LINE LASER OPERATTING MANUAL
需要绿色
Safety Instructions
Please read thoroughly and comply with the Safety Instructions and User Manual before using
this product. Failure to read and follow may void the warranty.
WARNING!
Class 2 Laser Product
Max. Power Output: ≤ 1mW
Wavelength: 510nm-640nm
LASER RADIATION:
DO NOT STARE INTO BEAM.
DO NOT DIRECT EYE EXPOSURE.
ACOID VIEW WITH OPTICAL INSTRUMENTS.
ATTENTION:
Read all instructions prior to operating this laser tool. Do not remove any labels from tool.
• Do not set up laser tool at eye level or operate the tool near a reflective surface as the laser
beam could be projected into your eyes or into the eyes of others.
• While the product is in operation, be careful not to expose your eyes to the emitting laser beam
(Green/Red light source). Exposure to a laser beam for an extended time may be hazardous to
your eyes.
• Do not attempt to view the laser beam through optical tools such as telescopes as serious eye
injury may result.
• Do not disassemble or modify the laser in any way. Modifying the tool may result in hazardous
Laser Radiation Exposure.
• Do not operate the laser around children or allow children to operate the laser. Serious eye
Laser Horizontal port
Laser Vertical port
Plumbing Dots port
Pulse button
LED indicator
Laser Switch
button
Battery cover
1/4” & 5/8 ‘’
threaded mount
Main switch
Button

METSYS ML2/3 LINE LASER OPERATTING MANUAL
injury may result.
• An exposure to the beam of a Class 2 laser is considered safe for a maximum of 2 seconds.
Eyelid reflexes will normally provide adequate protection.
• The following label/print samples are placed on the product to inform of the laser class for your
convenience and safety.
User Guide, Maintenance and Care
• When not in use please power OFF the tool and place the pendulum lock in its locked position.
• In Manual Mode, self-leveling is OFF. The accuracy of the beam is not ensured to be level.
• The laser tool is sealed and calibrated at the plant to the accuracy specified.
• It’s recommended to carry out an accuracy check before its first use and periodic checks during
future use especially for precise layouts.
• Do not store the laser tool in direct sunlight or expose it to high temperatures.
The housing and some internal parts are made of plastics and may become deformed at high
temperatures.
• Exterior plastic parts may be cleaned with a damp cloth. Although these parts are solvent
resistant, NEVER use solvents. Use a soft, dry cloth to remove moisture from the tool before
storage.
• Store the tool in its case when not in use. If storing for extended time, remove batteries before
storage to prevent possible damage.
• Do not dispose of this product with household waste.
• Always dispose of batteries per local code.
• Please recycle in line with local provisions for the collection and disposal of electrical and
electronic waste under the WEEE Directive.
Battery Safety
• Keep the battery away from children, and pets.
• Please pay attention to the position of the positive and negative pole.
• Please replace new alkaline batteries instead of carbon batteries. The battery capacity should
be more than 1500mA each.
• Do not mix old and new batteries. Replace all of them at the same time with new batteries of
the same brand and type.
• When the device will not be used for a long time, please remove the batteries and store them
in dry condition.

METSYS ML2/3 LINE LASER OPERATTING MANUAL
Operation Modes
Turn ON the laser tool:
•Method 1: Slide the side switch to the Unlocked Position to turn on the laser tool.
•Method 2: When the pendulum in Locked Position, press operation button and hold for ≥ 2
seconds to turn on the laser tool.
•The LED Indicator will light up when the laser tool turn on.
Lines switching:
•Short presses of the operation button repeatedly to switch the composition of different laser
lines.
• Laser line will switches in the following order:
①All lasers light up ⇒②Horizontal Line ⇒③Vertical Line ⇒④Horizontal Line + Vertical Line
⇒⑤Down Dot + Up Dot
Switch to Pulse Mode:
•Short press of the Pulse button to turn the Pulse Mode on, the LED Indicator will light up.
Note: The laser beam is dimmer in pulse mode.
Turn OFF the laser tool:
If the laser tool is in self-leveling mode: Slide the side switch to the Locked Position to turn laser
tool OFF.
If the laser tool is in manual mode:
• Method 1: Slide the side switch to the Unlocked Position, and then slide the pendulum again to
the Locked Position to turn laser tool OFF.
• Method 2: Short press of the operation button to switch the laser line in order. After “⑤Down
Dot + Up Dot”, short press of the operation button again to turn laser tool OFF.
Note: The laser level can only be turned off when the side switch is in its Locked Position.
Self-leveling Mode
• is enabled when the laser tool is switched to the unlocked position.
• the laser will blink fast when tool is out of self-leveling range (±3.5°).
Note: When using Self-leveling mode, please place this laser tool on a level surface.
Manual Mode
• Slide the side switch to the Locked Position, then press Laser button and hold for 3 seconds to
turn on the manual mode.
• The laser beam(s) will blink about every 3-5 seconds to notify the user

METSYS ML2/3 LINE LASER OPERATTING MANUAL
Pulse Mode
•Under pulse mode, Laser tool can work with a laser detector for working in a brighter
environment or a larger working distance.
Under Pulse model, the laser beam will enter into power-saving condition, which leads to
longer battery life. Users are recommended to use this model for green beam in indoor
uses.
• Turn on the laser tool, short press of the Pulse button will turn the Pulse Mode on and the LED
Indicator will light up. The laser beam is dimmer in pulse mode.
• Press and hold the Operation Button again for 3 seconds to back Normal Mode, and the
brightness of the laser line will return to normal.
• Please turn on the pulse mode when using the laser detector.
Specifications
Model
ML-2Red Beam
ML2P Red Beam
ML2PG Green Beam
Laser Wavelength
635-660nm
510-520nm ( Dot:
635-650nm)
Laser Class
Class 2 (IEC/EN60825-1/2014), ≤1mW
Leveling Accuracy
±3mm/10m
±3mm/10m
Horizontal/Vertical Accuracy
Plumb Dot Accuracy
±3mm/10m
Fan angle
H: 360 ° / V: 140°
Leveling/Compensation
Range
±3.5°
Operation Temperature
Range
0℃~+45℃
Storage Temperature Range
-20℃~+60℃
Operating Time (all laser
beams on)
Approx 10 Hours
Approx 7 Hours
Approx 4hrs ( 4AA) /
10hrs ( Rechargeable)
Working Distance (Line)
30m
30m
30m
Working Distance (Dot)
N/A
50m
50m
IP Rating
IP54
Mount Size
1/4”-20&5/8”-11
Power Source
4×˝AA˝ (LR6) / Rechargeable Battery (LR6)
Note:
Appearance and specifications may differ due to product improvement.
Working distance varies depending on the operating environment.
Battery life depends on battery capacity and quality, it is recommended to use a large capacity
battery.

METSYS ML2/3 LINE LASER OPERATTING MANUAL
ML3 / ML3G Product Overview
1. Operation Button
2. Vertical Laser Windows (V1/V2)
3. Horizontal laser window
4. Plumbing Laser Window
5. Main switch button
6. 1/4”-20 threaded mount
7. Battery cover
8. Laser control button (Press for lines / Hold for pulse model).
Operation Modes
Turn ON the laser tool:
•Method 1: Slide the side switch to the Unlocked Position, turn on horizontal line and
self-leveling mode in default.
•Method 2: When the side switch is in the Locked Position, press button and hold for ≥ 2
seconds to turn on the laser tool. Turn on horizontal line and manual mode in default.
Lines switching:
•Turn on the laser tool, short press of the button repeatedly to switch the composition of
different laser lines.
• Laser line will switches in the following order:
①One Horizontal Line (default)⇒②One Vertical Line + Down Dot⇒③Two Vertical Lines +
Vertical Laser
Windows v1
Main switch
button
1/4”-20 threaded
mount
Plumbing Laser
Window
Battery cover
Laser control
button
Horizontal laser window
Vertical Laser Windows v2

METSYS ML2/3 LINE LASER OPERATTING MANUAL
Down Dot ⇒④All lines and dots light up
Switch to Pulse Mode:
•Turn on the laser tool, long press of the Operation Button to turn on Pulse Mode, and can be
used with a laser detector.
Note: The laser beam is dimmer in pulse mode.
Turn OFF the laser tool:
If the laser tool is in self-leveling mode: Slide the side switch to the Locked Position to turn laser
tool OFF.
If the laser tool is in manual mode:
• Method 1: Slide the side switch to the Unlocked Position, and then slide the switch again to the
Locked Position to turn laser tool OFF.
• Method 2: Short press of the button to switch the laser line in order. After “④All lines and
dots light up”, short press of the button again to turn laser tool OFF.
Note: The laser level can only be turned off when the side switch is in the Locked Position.
Self-leveling Mode
• is enabled when the laser tool is switched to the unlocked position.
• has laser plumb blink fast when tool is out of self-leveling range (±3.5°).
Note: When using Self-leveling mode, please place this laser tool on a level surface.
Manual Mode
• Slide the side switch to the Locked Position, then press button and hold for ≥ 2 seconds to turn
on the manual mode.
• The laser beam(s) will blink about every 3-5 seconds to notify the user.
Specifications
Model
ML3 Red Beams
ML3G Green Beams
Laser Wavelength
635-660nm
510-520nm
Laser Class
Class 2 (IEC/EN60825-1/2014), ≤1mW
Leveling Accuracy
±3mm/10m
Horizontal/Vertical Accuracy
±3mm/10m
Plumb Dot Accuracy
1.4mm/1m
Leveling/Compensation Range
±3.5°
Working Distance (Line)
20m
25m

METSYS ML2/3 LINE LASER OPERATTING MANUAL
Operating Time (all laser beams on)
Approx 8 hrs
Approx 3 hrs /7hrs ( Rechargeable)
Mount Size
1/4˝-20
Power Source
4×˝AA˝ (LR6) / Rechargeable ( LR6)
IP Rating
IP54
Operation Temperature Range
0℃~+45℃
Storage Temperature Range
-20℃~+60℃
Other manuals for ML3
1
This manual suits for next models
4
Table of contents
Other Metsys Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Red Ion
Red Ion PAX2S installation guide

PCE Americas
PCE Americas PCE-WT 1N manual

Ahlborn
Ahlborn ALMEMO 2490-2 operating instructions

Spectrum Technologies
Spectrum Technologies LightScout 3415F product manual

MMA
MMA Evobalance 10 Assembly instruction

PRECISION DIGITAL
PRECISION DIGITAL PD8-7000 Series instruction manual