EM-5426 Rev.7 P. 1 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 80mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 30 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Zero Adj.
Span Adj.
Connection
Diagram
Specifications
Euro Type
Connector Terminal Block
INSTALLATION
Set the unit so that its DIN rail adaptor is at the bottom.
Hang the upper hook at the rear side of the unit on the DIN
rail and push in the lower. When removing the unit, push
down the DIN rail adaptor utilizing a minus screwdriver
and pull.
DIN Rail
35 mm wide
Spring Loaded
DIN Rail Adaptor
CURRENT LOOP SUPPLY MODEL F2DY
F2DY
EM-5426 Rev.7 P. 2 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
1234
5678
107 (4.21) [1.5 (.06)]
DIN RAIL
35mm wide
22.5 (.89)
75 (2.95)
• When mounting, no extra space is needed between units.
■CONNECTION DIAGRAM
+
–
+
–
OUTPUT
3
5
6
POWER
7
8
2
4
1
+
–
+
–
–
+
MONITOR
(1 – 5V DC)
2-WIRE
TRANSMITTER
V
WIRING INSTRUCTIONS
■EURO TYPE CONNECTOR TERMINAL
Applicable wire size: 0.2 to 2.5 mm2
Stripped length: 7 mm
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 30 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 30 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.

Other MG Power Supply manuals

MG 18KDU User manual

MG

MG 18KDU User manual

MG 10DY User manual

MG

MG 10DY User manual

MG Mini-M M2DY User manual

MG

MG Mini-M M2DY User manual

MG R8-PS1 User manual

MG

MG R8-PS1 User manual

MG W5DY User manual

MG

MG W5DY User manual

MG HDY2 User manual

MG

MG HDY2 User manual

MG MDC6 User manual

MG

MG MDC6 User manual

MG M80DY User manual

MG

MG M80DY User manual

MG 10DNY User manual

MG

MG 10DNY User manual

MG 10DU User manual

MG

MG 10DU User manual

MG Mini-M M2DYS User manual

MG

MG Mini-M M2DYS User manual

MG M6NPS2 User manual

MG

MG M6NPS2 User manual

Popular Power Supply manuals by other brands

H3C PSR1200-12A manual

H3C

H3C PSR1200-12A manual

Datel DMS-PS-CM datasheet

Datel

Datel DMS-PS-CM datasheet

Delta PMC-05V015W1A Series instruction manual

Delta

Delta PMC-05V015W1A Series instruction manual

Triax PSU 1218/12 quick guide

Triax

Triax PSU 1218/12 quick guide

Satel APS30BO manual

Satel

Satel APS30BO manual

Vertiv Liebert ITA2 quick start guide

Vertiv

Vertiv Liebert ITA2 quick start guide

Pulsar PSAC 04244 manual

Pulsar

Pulsar PSAC 04244 manual

ABB CPS6000 quick start guide

ABB

ABB CPS6000 quick start guide

Mesa 4P20 manual

Mesa

Mesa 4P20 manual

Lacme SECUR 100 user guide

Lacme

Lacme SECUR 100 user guide

Thermo Scientific PowerEase PS0300 user guide

Thermo Scientific

Thermo Scientific PowerEase PS0300 user guide

Anatek 6000 Series Technical manual

Anatek

Anatek 6000 Series Technical manual

Rosewill Tachyon-550 user manual

Rosewill

Rosewill Tachyon-550 user manual

turck PSU67-3P-1S-2L-24250-F quick start guide

turck

turck PSU67-3P-1S-2L-24250-F quick start guide

Televes NT12F user manual

Televes

Televes NT12F user manual

KTI Networks KPW-2012-D user manual

KTI Networks

KTI Networks KPW-2012-D user manual

H3C PS-2202-11L manual

H3C

H3C PS-2202-11L manual

turck PSU67-3P-1MP-2M5-24200-F quick start guide

turck

turck PSU67-3P-1MP-2M5-24200-F quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.