manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MG
  6. •
  7. Power Supply
  8. •
  9. MG R8-PS1 User manual

MG R8-PS1 User manual

Other MG Power Supply manuals

MG 10DY User manual

MG

MG 10DY User manual

MG M6NPS2 User manual

MG

MG M6NPS2 User manual

MG 10DU User manual

MG

MG 10DU User manual

MG W5DY User manual

MG

MG W5DY User manual

MG HDY2 User manual

MG

MG HDY2 User manual

MG F2DY User manual

MG

MG F2DY User manual

MG Mini-M M2DYS User manual

MG

MG Mini-M M2DYS User manual

MG MDC6 User manual

MG

MG MDC6 User manual

MG Mini-M M2DY User manual

MG

MG Mini-M M2DY User manual

MG 18KDU User manual

MG

MG 18KDU User manual

MG M80DY User manual

MG

MG M80DY User manual

MG 10DNY User manual

MG

MG 10DNY User manual

Popular Power Supply manuals by other brands

Videx 520MR Installation instruction

Videx

Videx 520MR Installation instruction

Poppstar 1008821 Instructions for use

Poppstar

Poppstar 1008821 Instructions for use

TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda

TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda 500A instruction manual

TDK-Lambda

TDK-Lambda 500A instruction manual

Calira EVS 17/07-DS/IU operating instructions

Calira

Calira EVS 17/07-DS/IU operating instructions

Monacor PS-12CCD instruction manual

Monacor

Monacor PS-12CCD instruction manual

VOLTIMA MagicBox 15 Installation and operating instructions

VOLTIMA

VOLTIMA MagicBox 15 Installation and operating instructions

Miller Auto Deltaweld 452 owner's manual

Miller

Miller Auto Deltaweld 452 owner's manual

BCP PUOUBK How to install

BCP

BCP PUOUBK How to install

HC 2210 manual

HC

HC 2210 manual

Agilent Technologies 6032A Service manual

Agilent Technologies

Agilent Technologies 6032A Service manual

Radial Engineering SB-48UB user guide

Radial Engineering

Radial Engineering SB-48UB user guide

Puls CT5.241 installation manual

Puls

Puls CT5.241 installation manual

OCZ ZX1250W Technical specifications

OCZ

OCZ ZX1250W Technical specifications

iseg ECH 238 manual

iseg

iseg ECH 238 manual

Agilent Technologies 6631B Service manual

Agilent Technologies

Agilent Technologies 6631B Service manual

Power XXL A Series instruction manual

Power

Power XXL A Series instruction manual

HP 6200B Operating and service manual

HP

HP 6200B Operating and service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

R8-PS1
P. 1 / 4EM-9789 Rev.4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
EXTENSION POWER SUPPLY MODULE
(non-isolated) MODEL R8-PS1
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing us. Before use, check the contents of
the package you received as below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■ PACKAGE INCLUDES:
Extension power supply module................................. (1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
DC Power supply: Rated voltage 24V DC
24V DC ±10%, approx. 11W
(@ internal power max. current 1.6 A)
Excitation supply (excitation for I/O module):
24V DC ±10%, operational current 8 A
(From power supply (exitation supply) connector, via con-
nector for internal bus, supplied to eacsh I/O module.
Power output current consumption must be under opera-
tional current.)
■GENERAL PRECAUTIONS
• Before you remove or mount the unit, turn off the power
supply and output signal for safety.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ven-
tilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not apply physical impact to the unit.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■POWER UP
• Turn the power on at the same time as the power/network
module or turn the R8-PS1 on before the power/network
module turned on. If the R8-PS1 is not turned on within 3
seconds after the power/network module is turned on, I/O
modules are not correctly recognized.
INSTALLATION
■HOW TO MOUNT THE MODULE ON DIN RAIL
Confirm that the locking clamps of the extension power supply module
are set. Insert the module in parallel to the next one while aligning the
grooves of both modules (A & B in the above figure).
Maintain it perpendicularly to the rail.
More I/O modules can be added in the same manner.
A
B
R8-PS1
P. 2 / 4EM-9789 Rev.4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
• Protective Cover
The protective cover is to be attached over the connected I/O module
at the right end.
Align the hooks on the cover with the grooves of the module and slide it
straight until the hooks are latched.
When removing the cover, pull it out while squeezing the hooks inward.
Groove
Hook
■HOW TO UNMOUNT THE MODULE FROM DIN RAIL
• Removing an intermediate module
Release the locking clamps and pull out straight the module.
Caution !
1)Be careful not to hurt your hand by pointed edges of the internal
communication bus connector.
2) I/O modules cannot hold tightly on the DIN rail by themselves without
power/network module. Secure them to the position if necessary by
using DIN rail end plates.
R8-PS1
P. 3 / 4EM-9789 Rev.4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
COMPONENT IDENTIFICATION
■ FRONT VIEW ■ SIDE VIEW
Internal Bus Connector
Connector for Power Supply and
Excitation Supply
Power indicator LED
Unused
24V
0V
+
-
FE1
Power
■POWER INDICATOR LED
Green, ON during module power on
■POWER SUPPLY, EXCITATION SUPPLY CONNECTOR ASSIGNMENT
PIN ID FUNCTION
No.
1 24V Power supply 24V DC
2 0V Power supply 0V DC
3 + Excitation supply 24V DC
4 − Excitation supply 0V DC
5 FE1 Grounding
1
2
3
4
5
■ POWER SUPPLY, EXCITAT ION SUPPLY CONNECTOR
ASSIGNMENT
Printed-circuit board connector (Phoenix Contact)
Header: MC1,5/5-GF-3,5
Plug component: TFMC1,5/5-STF-3,5
R8-PS1
P. 4 / 4EM-9789 Rev.4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
EXTERNAL DIMENSIONS unit: mm (inch)
115 (4.53)[6 (.24)]
[7 (.28)] [7 (.28)]
[3 (.12)] [4 (.16)]
[72 (2.83)]
55 (2.17)
24 (.95)
[6 (.24)]
DIN RAIL
(35 mm wide)
CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FE1
terminal to ground.
Caution:
FE1 terminal is NOT a protective conductor terminal.
EXC. SUPPLY
(24V)
INTERNAL
POWER (5V)
INTERNAL BUS
INTERNAL BUS
+24V
0V
+
–
FE1
CONNECTORCONNECTOR
CONNECTOR
Internal bus is connected for the modules near to the power /
network module out of the modules connected to the R8-PS1.
Internal power and Exc. supply are not connected. All modules
far from the power / network module are connected.
WIRING INSTRUCTIONS
■POWER SUPPLY, EXCITATION SUPPLY CONNECTOR
Printed-circuit board connector (Phoenix Contact)
Header: MC1,5/5-GF-3,5
Plug component: TFMC1,5/5-STF-3,5
Applicable wire size: 0.2 - 1.5 mm2,
stripped length 10 mm