Microsonic mic+ User manual

T2
T1
T2
T2
T1
T1 + T2
Set detect distance in
mm or cm
For single detect
point press T2
until »- - -« is
displayed
Choose » « for NCC or
» « for NOC
T1
T2
For window mode
operation set far
detect point in
mm or cm
T1 + T2
Press T1 and T2 simultaneously for about
3 s until welcome message has passed
T1 + T2
T2
T1
T1 + T2
T1 + T2
T1 + T2
T2
T1
Set switched output
Ready
Start here
Set sensor parameters alternatively numerically using LED-display...
Product description
The mic+sensor with one switched output
measures the distance to an object within
the detection zone contactless. Depen-
ding on the adjusted detect distance the
switched output is set.
All settings are done with two push-but-
tons and a three-digit LED-display
(TouchControl).
Light emitting diodes (three-colour LEDs)
indicate the switching status.
The output functions are changeable
from NOC to NCC.
The sensors are adjustable manually using
the numerical LED-display or may be trai-
ned using Teach-in processes.
Useful additional functions are set in the
Add-on-menu.
Using the LinkControl adapter (optional
accessory) all TouchControl and additio-
nal sensor parameter settings may be
made by a Windows-Software.
Important instructions for assembly and
application
All employee and plant safety-relevant
measures must be taken prior to assembly,
start-up, or maintenance work (see operation
manual for the entire plant and the operator
instruction of the plant).
The sensors are not considered as safety
equipment and may not be used to ensure
human or machine safety!
The mic+ sensors indicate a blind zone, in
which the distance cannot be measured. The
operating range indicates the distance of the
sensor that can be applied with normal re-
flectors with sufficient function reserve.
When using good reflectors, such as a calm
water surface, the sensor can also be used up
to its maximum range. Objects that strongly
absorb (e.g. plastic foam) or diffusely reflect
sound (e.g. pebble stones) can also reduce
the defined operating range.
Synchronisation
If the assembly distances shown in Fig.1 for
two or more sensors are exceeded the inte-
grated synchronisation should be used. Con-
nect Sync/Com-channels (pin 5 at the units re-
ceptable) of all sensors (10 maximum).
Fig. 1: Assembly distances, indicating syn-
chronisation/multiplex
Multiplex mode
The Add-on-menu allows to assign an indivi-
dual address »01« to »10« to each sensor
connected via the Sync/Com-channel (Pin5).
The sensors perform the ultrasonic measure-
ment sequentially from low to high address.
Therefore any influence between the sensors
is rejected.
The address »00« is reserved to synchronisa-
tion mode and deactivates the multiplex
mode. (To use synchronised mode all sensors
must be set to address »00«.)
≥0.35 m
≥0.40 m
≥2.50 m
≥2.50 m
≥1.10 m
≥2.00 m
≥8.00 m
≥18.00 m
≥4.00 m
≥30.00 m
Assembly instructions
Assemble the sensor at the installation lo-
cation.
Plug in the connector cable to the M 12
connector.
Fig. 2: Pin assignment with view onto sensor
plug and colour coding of the
microsonic connection cable
Start-up
mic+ sensors are delivered factory made with
the following settings:
Switched output on NOC
Detecting distance at operating range
and half operating range
Measurement range set to maximum ran-
ge
1
3
colour
+UB
-UB
brown
blue
4
2
5
D
-
black
white
Sync/Com. grey
1
5
2
34
Set the parameters of the sensor manually or
use the Teach-in procedure to adjust the
detect points.
Fig. 3: TouchControl
Operation
mic+sensors work maintenance free. Small
amounts of dirt on the surface do not influ-
ence function. Thick layers of dirt and caked-
on dirt affect sensor function and therefore
must be removed.
Note
mic+sensors have internal temperature
compensation. Because the sensors heat
up on their own, the temperature com-
pensation reaches its optimum working
point after approx. 30 minutes of operati-
on.
During normal mode operation, a yellow
LED D2 signals that the switched output
has connected.
During normal mode operation, the mea-
sured distance value is displayed on the
LED-indicator in mm (up to 999 mm) or
cm (from 100 cm). Scale switches auto-
matically and is indicated by a point on
top of the digits.
During Teach-in mode, the hysteresis
loops are set back to factory settings.
If no objects are placed within the detec-
tion zone the LED-indicator shows »- - -«.
If no push-buttons are pressed for 20 se-
conds during parameter setting mode the
made changes are stored and the sensor
returns to normal mode operation.
You can lock the key pad to provide in-
puts, see »Key lock and factory setting«.
You can reset the factory settings at any
time, see »Key lock and factory setting«.
Show parameters
Tapping push-button T1 shortly during nor-
mal mode operation shows »PAr« on the
LED-display. Each time you tap push-button
T1 the actual settings of the switched output
are shown.
Operating manual
mic+ Ultrasonic Sensors with
one switched output
c m m
m %
T 1
D
1 D
2 T
2
measuring range
LED D1 and D2
3-digit
LED-display
Push-buttons T1 and T2
mic+25/D/TC mic+25/E/TC
mic+35/D/TC mic+35/E/TC
mic+130/D/TC mic+130/E/TC
mic+340/D/TC mic+340E/TC
mic+600/D/TC mic+600/E/TC
Enclosure Type 1
For use only in industrial
machinery NFPA 79 applications.
The proximity switches shall be used with a Lis-
ted (CYJV/7) cable/connector assembly rated mi-
nimum 32 Vdc, minimum 290 mA, in the final in-
stallation.
2014/30/EU
HM 1909

...or with the Teach-in procedure
Adjust detect point
Place object at position
Press T2 until »d« is shown
Current measu-
ring value
Press T2 until »End« is
shown
Adjust window mode
Place object at position
Press T2 until »d« is shown
Place object at position
Current measu-
ring value
Press T2 until »End« is
shown
Current measu-
ring value
Adjust two-way reflectiv
barrier
Place reflector at position
Set NOC/NCC
Press T2 until »d« is shown
Current measu-
ring value
Press T2 until countdown
passed from »- 8 -« to »- 0 -«
and NOC or NCC symbol is
displayed
Press T2 until countdown
passed from »- 8 -« to »- 0 -«
and »End« is displayed
To change output function
press T2
Press T1 and T2 simultane-
ously until »End« is dis
played
Symbol
NOC or NCC
Symbol
NOC or NCC
Normal mode operation
T1 + T2
T1
T2
T1 + T2
Press T1 and T2 simultaneously for about 13 s
until »Add« is shown in the LED-display
T1 + T2
T2
T1
Start here
T2
T1
T1 + T2
Ready
»C01«: Display
bright
»C02«: Display dim-
med
»C03«: Display off
To optimize multi-
plex speed the hig-
hest sensor address
may be set.
Setting range »01«
to »10«
»F00«: no filter
»F01«: standard fil-
ter
»F02«: averaging fil-
ter
»F03«: foreground
filter
»F04«: background
filter
Defines the strength
of the chosen filter.
»P00«: weak filter
up to
»P09«: strong filter
Affects the size of
the detection zone.
»E01«: high
»E02«: standard
»E03«: slight
Minimum value:
blind zone
Maximum value: ne-
arwindow limit - 1
Low power mode Measurement filter Filter strength Foreground
suppression
Multiplex mode
device addressing
Multiplex mode
highest address
»00«: synchronisati-
on
»01« to »10«: sensor
address for multi-
plex mode
»oFF«: synchronisati-
on deactivated
Minimum value: sen-
sor-distant window
margin
Maximum value: 999
mm for mic+
25/...,mic+35/...,
999 cm for mic+
130/...,mic+340/...,
mic+600/...
Measurement range Calibration
display
Detection zone
sensitivity
Put plane reflector
vertically disposed in
front of sensor: in
an exact distance of
250 mm for mic+
25... and mic+35...
and 900 mm for all
other typs.
Adjust display to
250 mm or 900 mm.
Confirm calibration
with T1 + T2.
T1 + T2
T1 T2
T1 + T2
T2
T1
T1 + T2
T1 T2
T1 + T2
T2
T1
T1 + T2
T1 T2
T1 + T2
T2
T1
T1 + T2
T1 T2
T1 + T2
T2
T1
T1 + T2
T1 T2
T1 + T2
T2
T1
T1 + T2
T1 T2
T1 + T2
T2
T1
T1 + T2
T1 T2
T1 + T2
T2
T1
T1 + T2
T1 T2
T1 + T2
T2
T1
Delay in seconds
between the detec-
tion of an object
and the output of
the measured dis-
tance in case of ob-
ject approach (beha-
ves as on-delay).
"00": 0 s (no delay)
up to
"20": 20 s response
time
Response time
T1 + T2
T1 T2
T1 + T2
T2
T1
Note
Changes in the Add-on
menu may impair the
sensor function.
A6, A7, A8 , A10 , A11,
A12 have influence on
the response time of
the sensor.
Hysteresis
switched output
Minimum value:
»001«
Maximum value: dif-
ference between
maximum range and
detect point - 1
During window
mode operation hys-
teresis influences
both detect points.
T1 + T2
T1 T2
T1 + T2
T2
T1
Usefull additional functions in Add-on menu (for experienced users only, settings not required for standard applications)
Teach-in swítched output
Key lock and factory setting
Activate/deactivate
TouchControl
Reset to factory set-
ting
Turn supply voltage
OFF
While pressing T1
turn supply voltage
ON until »on« or
»off« is displayed
Turn supply voltage
OFF
Turn supply voltage
ON while pressing T1
and keep it pressed
for ca. 13 s until
»rESEt« has passed
through the display
To activate or
deactivate press T1
»on« or
»off«
To activate or
deactivate press T1
»on« or
»off«
Normal mode operation

*5395*
MV-DO-041942-620674
Technical data
blind zone
operating range
maximum range
angle of beam spread
0 to 30 mm
250 mm
0 to 65 mm
350 mm
350 mm
Please see detection zone
600 mm
Please see detection zone
0 to 200 mm
1.300 mm
0 to 350 mm
3.400 mm
2.000 mm
Please see detection zone
5.000 mm
Please see detection zone
0 to 600 mm
6.000 mm
8.000 mm
Please see detection zone
transducer frequency
resolution, sampling rate
reproducibility
accuracy
320 kHz
0,025 mm
400 kHz
0,025 mm
± 0,15 %
± 1 % (Temperature drift internal compensated,
± 0,15 %
± 1 % (Temperature drift internal compensated,
detection zones
for different objects:
The dark grey areas are determind
with a thin round bar (10 or 27 mm dia.)
and indicate the typical operating range
of a sensor. In order to obtain the light grey
areas, a plate (500 x 500 mm) is introduced
into the beam spread from the side.
In doing so, the optimum angle between
plate and sensor is always employed.
This therefore indicates the maximum
detection zone of the sensor.
It is not possible to evaluate ultrasonic
reflections outside this area.
opperating voltage UB
voltage ripple
may be deactivated1), 0,17%/K without compensation)
may be deactivated1), 0,17%/K without compensation)
9 V to 30 V DC, reverse polarity protection, Class 2
±10 %
9 V to 30 V DC, reverse polarity protection, Class 2
±10 %
200 kHz
0,18 mm
120 kHz
0,18 mm
± 0,15 %
± 1 % (Temperature drift internal compensated,
± 0,15 %
± 1 % (Temperature drift internal compensated,
80 kHz
0,18 mm
± 0,15 %
± 1 % (Temperature drift internal compensated,
may be deactivated1), 0,17%/K without compensation)
may be deactivated1), 0,17%/K without compensation)
9 V to 30 V DC, reverse polarity protection, Class 2
±10 %
9 V to 30 V DC, reverse polarity protection, Class 2
±10 %
may be deactivated1), 0,17%/K without compensation)
9 V to 30 V DC, reverse polarity protection, Class 2
±10 %
no-load supply current
housing
≤80 mA
Brass sleeve, nickel-plated, plastic parts: PBT, TPU;
≤80 mA
Brass sleeve, nickel-plated, plastic parts: PBT, TPU;
Ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
Ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
class of protection to EN 60529
norm conformity
type of connection
controls
IP 67
EN 60947-5-2
IP 67
EN 60947-5-2
5-pin initiator plug, PBT
2 push-buttons (TouchControl)
5-pin initiator plug, PBT
2 push-buttons (TouchControl)
≤80 mA
Brass sleeve, nickel-plated, plastic parts: PBT, TPU;
≤80 mA
Brass sleeve, nickel-plated, plastic parts: PBT, TPU;
Ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
Ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
≤80 mA
Brass sleeve, nickel-plated, plastic parts: PBT, TPU;
Ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
IP 67
EN 60947-5-2
IP 67
EN 60947-5-2
5-pin initiator plug, PBT
2 push-buttons (TouchControl)
5-pin initiator plug, PBT
2 push-buttons (TouchControl)
IP 67
EN 60947-5-2
5-pin initiator plug, PBT
2 push-buttons (TouchControl)
indicators
programmable
operating temperature
storage temperature
3-digit LED-display, 2 three-colour LEDs
Yes, with TouchControl and LinkControl
3-digit LED-display, 2 three-colour LEDs
Yes, with TouchControl and LinkControl
-25°C to +70°C
-40°C to +85°C
-25°C bis +70°C
-40°C bis +85°C
Weight
switching hysteresis1)
switching frequency1)
response time1)
150 g
3 mm
150 g
5 mm
25 Hz
32 ms
12 Hz
64 ms
3-digit LED-display, 2 three-colour LEDs
Yes, with TouchControl and LinkControl
3-digit LED-display, 2 three-colour LEDs
Yes, with TouchControl and LinkControl
-25°C bis +70°C
-40°C bis +85°C
-25°C bis +70°C
-40°C bis +85°C
3-digit LED-display, 2 three-colour LEDs
Yes, with TouchControl and LinkControl
-25°C bis +70°C
-40°C bis +85°C
150 g
20 mm
210 g
50 mm
8 Hz
92 ms
4 Hz
172 ms
270 g
100 mm
3 Hz
240 ms
time delay before availibility
order No.
switched output
< 300 ms < 300 ms
mic+25/D/TC
pnp, UB- 2 V, Imax = 200 mA
mic+35/D/TC
pnp, UB- 2 V, Imax = 200 mA
order No.
switched output
switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof
mic+25/E/TC
npn, -UB+ 2 V, Imax = 200 mA
mic+35/E/TC
npn, -UB+ 2 V, Imax = 200 mA
< 300 ms < 380 ms
mic+130/D/TC
pnp, UB- 2 V, Imax = 200 mA
mic+340/D/TC
pnp, UB- 2 V, Imax = 200 mA
< 450 ms
mic+600/D/TC
pnp, UB- 2 V, Imax = 200 mA
switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof
mic+130/E/TC
npn, -UB+ 2 V, Imax = 200 mA
mic+340/E/TC
npn, -UB+ 2 V, Imax = 200 mA
switchable NOC/NCC, short-circuit-proof
mic+600/E/TC
npn, -UB+ 2 V, Imax = 200 mA
1) Can be programmed with TouchControl and LinkControl
switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof
+UB
-UB
D
Sync/Com
1
2
4
5
3
1 pnp switched output
U
+UB
-UB
E
Sync/Com
1
2
4
5
3
1 npn switched output
U
mic+25…
mic+35…
mic+130…
mic+340…
mic+600…
0 cm
5 cm
10 cm
15 cm
20 cm
25 cm
30 cm
35 cm
Plate
Round bar
10 cm
5 cm
0 cm
5 cm
10 cm
0 cm
10 cm
20 cm
30 cm
40 cm
50 cm
60 cm
Plate
Round bar
20 cm
10 cm
0 cm
10 cm
20 cm
35 cm
0 m
0,4 m
0,8 m
1,2 m
1,6 m
2 m
1,3 m
Plate
Round bar
0,8 m
0,4 m
0 m
0,4 m
0,8 m
0 m
0,8 m
1,6 m
2,4 m
3,2 m
4 m
4,8 m
5,6 m
3,4 m
Plate
Round bar
1,6 m
0,8 m
0 m
0,8 m
1,6 m
0 m
1,2 m
2,4 m
3,6 m
4,8 m
6 m
7,2 m
8,4 m
Plate
Round bar
2,4 m
1,2 m
0 m
1,2 m
2,4 m
microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T+49 231 975151-0 / F+49 231 975151-51 / E[email protected] / Wmicrosonic.de
The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.
Länna, S-142 50 SKOGÅS
Stockholm, Sweden Ordertel 08-771 00 04
Orderfax 08-771 62 00 Växel 08-771 02 20
Teknisk 08-771 35 80
Email [email protected]
Internet www.hemomatik.se
This manual suits for next models
10
Other Microsonic Security Sensor manuals
Popular Security Sensor manuals by other brands

MSA
MSA Suretyman Anchorage Sling User instructions

schmersal
schmersal BNS 33S Series operating instructions

RKI Instruments
RKI Instruments 61-1000RK-05 Operator's manual

B.E.G.
B.E.G. LUXOMAT PD4-S-K manual

Bircher Reglomat
Bircher Reglomat EasyMotion operating instructions

U-Prox
U-Prox WDC mini user manual