MICROWELL DRY SIREN mono Operating manual

SWIMMING POOL DEHUMIDIFIER DRY SIREN
SWIMMING POOL
DEHUMIDIFIER
User´s and installation manual
Version: 01/2018
Model: DRY SIREN mono
DRY SIREN due

2 | U s e r ´ s a n d i n s t a l l a t i o n m a n u a l D R Y S I R E N
P a g e 2 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
1. CONTENT
Thank you for purchasing Microwell swimming pool dehumidifier DRY
SIREN. You hold in your hands probably the most advanced and most
futuristic device for your pool. Before you use this device, it is necessary to
carefully read the entire User’s manual. Please keep the User’s manual
available in the case a reference is required in the future. Please provide
this information also to each user of the device. Please mind local
regulations in your country regarding installation and usage of this
dehumidifier which are valid in addition to this User’s manual.
1. CONTENT ................................................................................................................................................. 2
2. WASTE DISPOSAL INFORMATION............................................................................................................. 4
3. SAFETY MEASURES................................................................................................................................... 4
3.1 ELECTRICAL SAFETY................................................................................................................................ 4
3.2 USAGE PRECAUTIONS ............................................................................................................................ 5
3.3 HANDLING PRECAUTIONS...................................................................................................................... 6
4. PARTS LIST ............................................................................................................................................... 7
5. TOOL LIST............................................................................................................................................... 10
6. INSTALLATION –CEILING UNIT............................................................................................................... 12
6.1 BASIC MANIPULATION ......................................................................................................................... 12
6.2 APPROPRIATE POSITION OF CEILING UNIT........................................................................................... 15
6.3 FIXATION ON ACEILING –CONCRETE /WOOD .................................................................................... 17
7. INSTALLATION –COMPRESSOR UNIT ..................................................................................................... 33
8. INSTALLATION –ELECTRICAL CONNECTION ........................................................................................... 34
9. DRAINAGE OF CONDENSATE WATER ..................................................................................................... 38
10. INSTALLATION –REFRIGERANT CONNECTION........................................................................................ 40
10.1 DETERMINING THE PIPE LENGTH AND REFRIGERANT CHARGE.............................................................................. 40
10.2 REFRIGERANT PIPING................................................................................................................................. 41
10.3 FLARING WORK ........................................................................................................................................ 42
11. UNIT TEST –PAIRING ............................................................................................................................. 46
11.1 AFTER PAIRING, TEST RUN ................................................................................................................... 53
12. MOBILE APPLICATION - INSTRUCTIONS FOR USE.................................................................................. 54
12.1 CONTROL ................................................................................................................................................ 54
13. TECHNICAL DATA .................................................................................................................................. 58
13.1 TECHNICAL DATA TABLE ............................................................................................................................. 58
13.2 EXTRACTION RATE DIAGRAM ....................................................................................................................... 59
13.3 WIRING DIAGRAM .................................................................................................................................... 59
14. HINTS & TIPS.......................................................................................................................................... 60
14.1 ERROR MESSAGES ..................................................................................................................................... 60

D R Y S I R E N U s e r ´ s a n d i n s t a l l a t i o n m a n u a l | 3
P a g e 3 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
14.2 TROUBLESHOOTING –SAVE TIME AND MONEY................................................................................................ 60
14.3 MAINTENANCE......................................................................................................................................... 63
14.4 SUMMER SHUT-DOWN............................................................................................................................... 63
14.5 SUPER-CHLORINATION CLEANING................................................................................................................. 63
14.6 START-UP DURING CONSTRUCTION............................................................................................................... 64
14.7 MICROLIGHT+ ........................................................................................................................................ 64
15. WARRANTY............................................................................................................................................ 64
15.1 INSTALLATION CHECK-LIST AND WARRANTY CARD ............................................................................. 66

4 | U s e r ´ s a n d i n s t a l l a t i o n m a n u a l D R Y S I R E N
P a g e 4 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
3. SAFETY MEASURES
2. WASTE DISPOSAL INFORMATION
When using this dehumidifier in the European countries, the following information must be
followed:
DISPOSAL: Do not dispose this product as unsorted municipal waste. It is prohibited to
dispose this dehumidifier in domestic / household waste. It is prohibited to dispose this
appliance into forests or natural landscape. This could lead into local soil pollution.
Collection of such waste must be treated individually.
DISPOSAL POSSIBILITIES:
1. The municipality has established a collection system where electronic waste can be
disposed.
2. When buying a new product, the retailer or the manufacturer may take back the old
appliance free of charge.
3. As old appliance may contain valuable resources which could be sold to scrap material
dealers.
4. Disposal of packaging materials such as carton box or plastic / bubble foil can be recycled.
This device is primarily designed for use in indoor swimming pool, sauna or spa. Alternative use is in
laundries, drying rooms or other humid areas requiring dehumidification.
Model Microwell DRY SIREN is designed for halls with swimming pool surface of up to 60m2.
It is necessary to follow instructions in this User’s manual and local regulations in your country that
regulate the installation and usage of this device. Incorrect, improper or operations contradictory to
this User’s manual may lead to an injury or property damage and will lead to loss of warranty. To
prevent injury or property damage the following instructions must be followed:
3.1 ELECTRICAL SAFETY
The device operates at dangerous electrical current.
Only authorized person with particular electro-technical qualification can manipulate with unit.
Danger of electrical shock.
For proper and optimal operations of the device is it necessary to maintain the air
temperature in the swimming pool room / hall 2-3°C higher than actual water temperature
in the pool. It is also necessary to keep the air temperature in the swimming pool room / hall
in operational temperature range of the dehumidifier (specified in Technical data section).
Higher temperatures than operational temperature range may cause damage to the unit
resulting from overheating of the unit.

D R Y S I R E N U s e r ´ s a n d i n s t a l l a t i o n m a n u a l | 5
P a g e 5 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
Do not exceed the required power supply.
Do not turn the device on that shows signs of possible damage such as broken packaging, broken or
otherwise damaged unit’s chassis or cover, smoke, smell, etc.
It is necessary to use appropriate Residual current circuit breaker (RCD) for connection of the dehumidifier to
main power supply.
Do not manipulate with the device with wet hands.
Do not clean the device with water.
Before cleaning the device, switch off the circuit breaker of the unit’s power supply.
Installation, service or repair must be performed by qualified technician.
When the device is not intended to be used for a longer time, we recommend switching the circuit breaker of
the unit’s power supply off.
Compressor unit must be installed in vertical position. Ceiling unit must be leveled to avoid condensate
water to enter electrical part of the unit.
It is forbidden to install the unit close to devices that may cause electrical or frequency disturbance such as
welding machines, motors or rotors, WIFI/WLAN routers or repeaters.
It is forbidden to alter electrical installation of the device. It is also forbidden to alter any other part or
functionality of the device.
3.2 USAGE PRECAUTIONS
Please read the entire User’s and Installation Manual prior you proceed with installation or usage of this
product. Do not continue or proceed if you have doubts, uncertainty or not full clarity about any step(s)
described in this User’s and Installation Manual.
Do not cover or block the intake or exhaust openings. It is forbidden to block or cover the intake or exhaust
openings with clothes, towels, buckets, canoes, ceiling beams, etc.
Do not install or place any heating appliances close to intake grilles / louvers. It could continually
overheat the dehumidifier and result in its malfunction or damage.
Do not climb up on or sit on the unit.
Do not place any objects on the top of the unit (e.g. boxes, flower vases, etc.).
Do not hang any objects on the unit.
Do not spray any flammable substances into the equipment; this might lead to fire.
Do not clean the equipment with aggressive cleaning agents, this might lead to damage or deformations.
When cleaning plastic parts do not use any cleaning agents unsuitable for the cover of the dehumidifier
(household cleaning agents, solvents, bleaching agents, benzene, diluents, rough cleaning powder, cresol,
chemical agents). Instead, sweep the dehumidifier cover with a soft cloth or a sponge.
Never throw or insert any objects into any hose or opening.
The cover of ceiling unit is made from acryl. The cover of compressor unit is made from powder coated
metal. Do not manipulate with lighted cigarette, cigarette ashes, or any other kind of fire in vicinity to this part.
Use this device exclusively for the intended purpose, as described in the attached instruction manual. Do not
use parts which are not recommended.
Do not drink or use the condensate water drained from the unit. Do not return the water back to the
swimming pool. The water may be contaminated with bacteria.
Children are not allowed to operate, touch or play with the unit.
Children are not allowed to manipulate with packaging, plastic / bubble foil. Risk of suffocation!
Prevent the children from injury or harm caused by any manipulation with the unit, its parts or its
packaging. Small parts like screws may be swallowed and cause suffocation or harm to health.
Do not leave the children in the swimming pool hall unattended.
The dehumidifier should be sized correctly and run max. 18 hours a day, optimum max. 12 hours a day. In
the case it runs more than 18 hours a day in long term it may fail, malfunction or get damaged. Warranty does
not cover such damages as the machine is considered undersized if running longer than 18 hours a day.

6 | U s e r ´ s a n d i n s t a l l a t i o n m a n u a l D R Y S I R E N
P a g e 6 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
3.3 HANDLING PRECAUTIONS
Leave the compressor unit in vertical upright position for at least 2 hours before the installation. This will
level the oil inside the compressor.
Transport of the compressor unit in lying position or turning the compressor unit over may harm the
compressor and will lead to loss of warranty.
The device must be handled with care and special attention avoiding any mechanical damage.
It is forbidden to apply any improper mechanical force onto the unit. This may cause mechanical damage to
the device.
It is forbidden to let the device fall freely onto the ground or any solid surface resulting in hard impact.
Please notify your reseller or distributor if you suspect that the unit was delivered damaged. Unit may seem
to work well at start but small damage can make the unit go out-of-order in short time. In such case the unit
must be inspected and approved for further use by your reseller.
Please notify your reseller or distributor if directly after installation you suspect that unit is not working in
perfect order.
In the case of device failure resulting from improper handling or mechanical damage (impact, hit, fall, etc.),
the manufacturer reserves the right to evaluate the continuity of warranty.

D R Y S I R E N U s e r ´ s a n d i n s t a l l a t i o n m a n u a l | 7
P a g e 7 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
4. PARTS LIST
The unit was delivered in 2 boxes on a wooden palette(s). After you unpack the boxes, please check
the content. It should include the following:
Name/Code
Picture
Name/Code
Picture
1 - Ceiling unit
1x
2 - Compressor unit
1x
3 - Tablet with
charger
1x
4 - User’s Manual
1x
5 - F8 fastener
4x
6 - ML1 D8 fixation
double nut
4x
7 - MX8 hex nut
d8
8x
12x if installation
on wooden beam
8 - TR8 threaded bar
M8x1000mm
2x
9 - MB8 flat washer
8x
12x if installation on
wooden beam,
additional washers
may be supplied MX10
10 - Scheme diagram
1x

8 | U s e r ´ s a n d i n s t a l l a t i o n m a n u a l D R Y S I R E N
P a g e 8 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
11 - Eight core
cable with
markings 123456
(mono), 12346
(due)
1x
12 - Three core cable
with markings
L1,N1,Earth
1x
13 - Back lift
assembly (1) with
anchor
1x
14 - Condensate drain
for compressor unit
1x
15 - Rope
14.5m
1x
16 - Front lift
assembly with
locking mechanism
(2) with anchor
1x
17 - Wall console
for compressor
unit
1 set
(on demand)
18 - Key set for
compressor unit
2x
19 –Bluetooth
receiver cable
(only DRY SIREN
due)
-
-
The pictures and drawings in Parts list may differ from those actually delivered. Some
parts may have been delivered upper hand and are thus not included in this shipment.
If you are unable to locate all parts or are unsure if the supplied parts are complete,
please contact your distributor.
Please note that the screws and dowels supplied with this dehumidifier are to be
used only with solid concrete. Please check your ceiling material and choose
appropriate screw and dowel.

D R Y S I R E N U s e r ´ s a n d i n s t a l l a t i o n m a n u a l | 9
P a g e 9 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
CEILING UNIT
1. Main cover
2. Air intake
3. Air outake
4. LED lamp + microLIGHT+
5. Bluetooth speaker
6. Auto dimmable light sensor, LED pairing indicator
7. Refrigerant connection Suction (1)
8. Refrigerant connection Discharge (2)
9. Electrical connection –L1, N1, Earth, 12346
10. Lifting mechanism
11. Fixation hooks and Fixation ropes
12. Condensate drain
13. Serial number plate
COMPRESSOR UNIT
1. Main cover
2. Door
3. Lock + keys
4. Condensate drain
5. Silent blocks
6. Refrigerant connection Suction (1)
7. Refrigerant connection Discharge (2)
8. Communication cable to ceiling unit –12346
9. Refrigerant plate
10. Serial number plate
11. Main power supply –L, N, Earth
12. Ceiling unit power supply –L1, N1, Earth
13. Serial RS port
14. Pairing button
15. Terminal connection for main power supply (L, N, Earth) and
ceiling unit power supply (L1, N1, Earth)
1
2
3
4
5
6
7
8
9
10
11
12
13
11
1
2
3
4
5
6
7
8
11
12
9
10

10 | U s e r ´ s a n d i n s t a l l a t i o n m a n u a l D R Y S I R E N
P a g e 10 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
16. Terminal for connection of communication cable –
123456
17. Compressor
18. Main PCB
5. TOOL LIST
In order to perform the installation correctly, you will need following tools:
Name/Code
Picture
Name/Code
Picture
19 - Drill
1x
20 - Drill bit 10mm
1x
If installation on a
wooden beam:
9mm and 11mm drill bit
8
11
12
15
18
16
17

D R Y S I R E N U s e r ´ s a n d i n s t a l l a t i o n m a n u a l | 11
P a g e 11 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
21 - Screwdriver
Phillips PH2
1x
22 - Screwdriver Slot
5/32
1x
23 - Small hammer
1x
24 - Tape measure
1x
25 - Spirit level
1x
26 - Combination wrench
/ open-end wrench -
2x13mm, 1x16mm,
1x17mm, 1x19mm,
1x22mm, 1x24mm or
adjustable
multiple
27 - Charging and
testing hoses with
valve, ½“ – 20UNF
2x
28 - Vacuum Pump
170l/min
1x
29 - Charging scales
+/-2g
1x
30 - Manifold valve
R410A
31 - R410A Bottle
1x
32 - Flaring tool –tube
1/2, 3/8
1x

12 | U s e r ´ s a n d i n s t a l l a t i o n m a n u a l D R Y S I R E N
P a g e 12 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
33 - Cutter –tube
1/2, 3/8
1x
34 - Tube Bender –tube
1/2, 3/8
35 –Saw for iron
1x
6. INSTALLATION –CEILING UNIT
Ceiling unit is designed for an installation at the ceiling or at lower ceiling. Typically the ceiling unit is
fixed into the concreted structure of the upper floor or wooden roof. Please make sure that the
material into which the ceiling unit is to be fixed is suitable for such installation. Manufacturer is not
responsible for damages or losses caused by an incorrect installation or inappropriate concrete or
wood type. Ideally it should be installed above the evaporation source. It should be installed on easy
accessible spot to allow maintenance and service.
Please view following concrete types and strengths.
Pressure class
fck,cyl (MPa)
fck,cube (MPa)
Appropriate
Threaded
bar TR8 L1
drill depth
Anchor for
lifting
mechanism
C8/10
8
10
No
N/A
N/A
C12/15
12
15
No
N/A
N/A
C16/20
16
20
Yes
80mm
60mm
C20/25
20
25
Yes
60mm
60mm
C25/30 and more
25 and more
30 and more
Yes
40mm
60mm
Concrete marking with additional request for seepage resistance: STN EN 206-1 –C25/30-XF2,XC2
(SK) –Cl 0,4 –Dmax 16 –S3, seepage 50mm according to STN EN 12390-8.
6.1 BASIC MANIPULATION
The unit is designed to be located on the ceiling. We, at Microwell, had to ensure a perfect balance
between weight and long-term durability with focus on reliability of the product. It is thus necessary
to mind below manipulation information and comply with them. Non-compliance may lead to
product damage, malfunction or failure. Manufacturer is not resosonsible for incorrect manipulation
or for manipulation not compliant to this User’s manual.
Ceiling unit is delivered in a box with polystyrene support from the bottom at sides.

D R Y S I R E N U s e r ´ s a n d i n s t a l l a t i o n m a n u a l | 13
P a g e 13 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
Do not place ceiling unit on side. The unit is not designed to stand on its side. Main cover damage
may occur in such position.
Do not place ceiling unit on the ground. Do not put the unit on an object or support holding the unit
in the center.
Do not place any objects such as drill tools, boxes, vacuum cleaners, etc. on the top of the ceiling
unit.
Do not hold ceiling in areas where forbidden (bluetooth speaker, LED lamp, air outlet). For
manipulation hold the unit on the side which is supported by metal structure. Do not hold in places
where plastic cover does not have metal support.

14 | U s e r ´ s a n d i n s t a l l a t i o n m a n u a l D R Y S I R E N
P a g e 14 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
DO NOT INSTALL THE CEILING UNIT IN BETWEEN THE WOODEN BEAMS OR SIMILAR
OBJECTS. Air flow on the outlet will be reflected from the object (wooden beam) and
redirected back to the unit. Thus the water collection process will be dramatically
reduced and the unit will be exposed to the risk of overheat.

D R Y S I R E N U s e r ´ s a n d i n s t a l l a t i o n m a n u a l | 15
P a g e 15 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
6.2 APPROPRIATE POSITION OF CEILING UNIT

16 | U s e r ´ s a n d i n s t a l l a t i o n m a n u a l D R Y S I R E N
P a g e 16 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
Please mind electrical safety requirement below to locate an electrical device close to pool water.
ZONE 1, IPX4
ZONE 2, IPX2
OUTSIDE THE ZONES
In the distance of 1250 mm or less
from the swimming pool edge, the
bottom edge of the unit must be in
the height of 2500 mm from the
swimming pool surface; if it is
embedded under the floor, then
2500 mm from the floor.
At least 1250 mm (i.e. out of the reach of the hand) from the lateral edge
of the wash basin, in the minimum height of 1200 mm above ground. It
cannot be placed above the wash basin.
In the distance of at least 1500 mm
from the vertical plane a round the
jumping platforms, diving boards
and 2500 mm above the highest
surface, where persons are likely to
stay.
If the unit is in the distance of less
or equal to 1250 mm horizontally
from the edge of the swimming
pool, then it must be raised up to
the height of 2500 mm from the
swimming pool surface; if the
pool is embedded under the floor,
then the unit must be raised up to
the height of 2500 mm from the
floor.
SWIMMING POOL
SWIMMING POOL
Swimming pools which are not
cleaned by jet water
in the distance of 1250 to 2000 mm from the swimming pool edge,
the unit must adhere to the standard and in the height
of at least 300 mm from the floor
HD, IEC
Swimming pools which
are not cleaned by jet water
In the distance of 2000 to 3500 mm
from the swimming pool edge, the
unit must adhere to the HD, IEC
standard and a minimum 150 mm
elevation above the ground is
required for sufficient air flow.
Installing the unit on the floor is
prohibited.
At least 1250 mm (i.e. out of the reach of the hand)
from the lateral edge of the shower cabinet. It cannot
be placed above the shower cabinet.
OUTSIDE THE ZONES OUTSIDE THE ZONES

D R Y S I R E N U s e r ´ s a n d i n s t a l l a t i o n m a n u a l | 17
P a g e 17 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
6.3 FIXATION ON A CEILING –CONCRETE / WOOD
1. Locate appropriate
location for the ceiling unit.
2. Mark the drilling holes according to Scheme
diagram (Part number 10). Position the drill hole for
lifting mechanism 800mm from the center in
between the 2 threaded bars (TR8 –part number 8)
800mm

18 | U s e r ´ s a n d i n s t a l l a t i o n m a n u a l D R Y S I R E N
P a g e 18 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
3a. Drill 6 holes (4 for TR8, 2 for Lifting mechanism).
/We advise to use vacuum cleaner simultaneously
when drilling to avoid dust and particles be spread
into entire room./

D R Y S I R E N U s e r ´ s a n d i n s t a l l a t i o n m a n u a l | 19
P a g e 19 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
CONCRETE
3b. Drill 4 holes (TR8) using 10mm bit by
concrete and 9mm bit by wood beam. Drill
2 holes (Lifting mechanism –Part number
13 and 16). Please refer to needed drilling
depth –section 6 INSTALLATION –CEILING
UNIT –table Concrete types and strength.
For wood we advise to drill completely
through. Please mind that wooden beam
must be statically resistant to hold weight
of DRY SIREN unit (53kg) and it must be
possible to drill 9mm hole through it
without changing the static conditions of
the wooden beam
4. By concrete insert 4 fasteners into the
holes for threaded bars. Fastener is part
number 5. Use small hammer or
appropriate.
5. Assemble 4 mounting threaded bars for ceiling unit
fixation. Use part numbers 5, 6, 7, 8, and 9. Please refer
to picture below.
MX
8

20 | U s e r ´ s a n d i n s t a l l a t i o n m a n u a l D R Y S I R E N
P a g e 20 o f 68 V e r s i o n : 0 1 / 2 0 1 8
SWIMMING POOL DEHUMIDIFIER DRY SIREN
WOOD
This manual suits for next models
1
Table of contents
Popular Other manuals by other brands

Bacharach
Bacharach Model 105 supplementary guide

Waeco
Waeco AirConServiceCenter ASC5100G operating manual

ICP DAS USA
ICP DAS USA DL-301 user manual

Ahlborn
Ahlborn ALMEMO 500 Supplementary instructions manual

Buyers Products Company
Buyers Products Company Truck Star BA0972 installation instructions

MSA
MSA IR5500 Installation guidelines