
Page 12
ErrorCodes:
EH60
Auto Defrost
When frost builds up on the evaporator
coils, the compressor will cycle off
and Auto Defrost function will run
automatically.
3 minute compressor operation delay
protection
After the unit has stopped, it can not be
restarted in the first 3 minutes to protect
compressor operation. The unit will restart
automatically after 3 minutes.
Auto-Restart
If the unit stops unexpectedly due to power
being cut, it will restart with the previous
function setting (except bucketless mode)
automatically when the power resumes.
Timer Function
• When activating the Timer function,
you are setting the timeuntil the unit
changes its power state. This means,
if the unit is on, activating the timer
function will set the timeuntil the unit
will turn off. If the unit is off, activating
the timer function will set the timeuntil
the unit will turn on.
• The time can be set after pressing the
timer button then using the up or down
buttons. These buttons will change
the time in 0.5 hour increments up to
10 hours. After 10 hours, the time will
change in 1 hour increments up to 24.
• If an error code appears during this time,
the timer function will be cancelled.
NOTICE
• When first using the dehumidifier,
operate the unit continuously 24 hours.
Make sure the plastic cover on the
continuous drain hose outlet is installed
properly so there are no leaks.
• This unit is designed to operate in a
working environment between 5°C/41°F
and 35°C/95°F.
• Make sure the water bucket is positioned
correctly so that the unit can operate
properly. When the water in the bucket
reaches a certain level, please be careful
while moving the unit to avoid spilling.
Operating
Instructions
Other Features
Timer Button:
Press this button to activate the Timer
function. The Timer LED will illuminate
indicating timer mode is being set.
0.0 will also appear on the display
indicating thenumber of hours from
now until the timer function will initiate.
When the timer function initiates, the
unit will changeitspower state. For
more information see Timer function
under other features on the next page.
- Room temperature sensor
error--Unplug the unit and plug
it back in. If error repeats, call
for service;
Protection Code:
P2 - Bucket is full-- Empty the
bucket and replace it in the
right position.
Eb Bucket malfunction--Replace
the bucket in the right position,
the malfunction clear.
Note:
EH61 - Tube Temperature sensor of
the evaporator error--Unplug
the unit and plug it back in. If
error repeats, call for service;
EH0b- Displayboard and master
control board communication
error.Unplug the unitand plug it
back in. If error repeats, call for
service;
When one of the above
and check for any obstructions.
Restartthe unit, if the malfunction is
the power cord. Contact the
manufacturer or its service agents or a
similar qualified person for service.