5. Data Report
The device will immediately send a version package Report and a report data with temperature and humidity and voltage
Values. The device sends data in the default configuration before any configuration is done.
ReportMaxTime: RA0713_ RA0713Y is 180s and RA72613 is 900s; (subject to factory
settings) ReportMinTime: 30s; ReportChange: 0;
Note: The device send data cycle has been programmed to be correct.
The interval between two reports must be the maximum time
The RA0713_R72613_RA0713Y device does not support the ReportChange function, that is, the function is
invalid. The sent report data string is always sent according to the ReportMaxTime period (starting to the end of the
first data as a period).
The data of the device Report is: soil moisture value, ReportType count = 1;
Note: 1. The value of ReportMaxTime is greater than (ReportType count *ReportMinTime + 10 units: seconds);
2. The device also supports Cayenne's TxPeriod cycle configuration instructions. Therefore, the device can
also perform a report according to the cycle time of the TxPeriod value; and at a certain time, the report period is
ReportMaxTime or TxPeriod, depending on which cycle time is configured last time;
3. After pressing the button, the device needs 35 seconds to process the sensor information, please be patient.
The data parsing reported by the device is referenced by the MiDoMet LoraWAN Application Command document
and www.midosmart.com
Report Configuration Example:
Description Device CmdID DeviceTy
pe PayLoadData
q
RA07
Series/
R726
Series/
R727
Series
0x05/0x0
9/0x0D
bytes
Unit:s)
tes Unit:s)
Reserved (5Bytes,Fixed 0x00)
p
Status(0x00
_success) Reserved (8Bytes,Fixed 0x00)
rtReq
Reserved (9Bytes,Fixed 0x00)
rtRsp
bytes
Unit:s)
tes Unit:s)
(1) Configure RA0713 device parameters MinTime = 30s, MaxTime
= 120s (120>30*1+10) Downlink: 0105001E00780000000000
Device returns:
8105000000000000000000 (configuration is successful)
8105010000000000000000 (configuration failed)
(2) Read RA0713 device parameters Downlink:
0205000000000000000000 Device returns:
8205001E00780000000000 (device current parameter)
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable
Change
Change≥
Change
Change
Change
number
1~65535
Any number between
1~65535 Can not be 0. Report per Min
Interval
Report per Max
Interval
Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V