Midtronics MDX ZIGBEE RADIO User manual

Doc No: TBD Page 1
The information contained herein is the confidential and proprietary property of Midtronics, Inc.
User’s Manual
MDX ZIGBEE RADIO
Revision: 1
Date: 08/12/14

Doc No: TBD Page 2
The information contained herein is the confidential and proprietary property of Midtronics, Inc.
Table of Contents
Table of Contents ........................................................................................................................................................... 2
1. Summary ................................................................................................................................................................ 3
2. MDX ZIGBEE RADI Installation ................................................................................................................... 4
3. Technical Specifications of MDX ZIGBEE RADI Module .................................................................... 4
3.1 Description of MDX ZIGBEE RADI module ...................................................................................... 4
3.2 MDX ZIGBEE RADI Module Specifications Table .......................................................................... 6
3.3 Table of Allowable Channels .................................................................................................................... 6
3.4 MDX ZIGBEE RADI Module Antenna Specifications Table ........................................................ 6
4. Agency Certifications for MDX ZIGBEE RADI ........................................................................................ 7
5. Battery Sensor Installation .............................................................................................................................. 7
6. Intended Use ......................................................................................................................................................... 8
7. Safety ........................................................................................................................................................................ 9
8. Patents .................................................................................................................................................................. 10
9. Limited Warranty ............................................................................................................................................. 10
10. Service .................................................................................................................................................................. 10
Reference Documents
Document Title Revision
Document Maintenance Contact Document Location
CGFS-W-201 Rev4
Gen 2 Dual Sensor Wiring
Instructions
4
Brad Walker
Global ield Service Manager
office.630.321.8006
Midtronics internal
document for training
approved installers. Available
upon Request

Doc No: TBD Page 3
The information contained herein is the confidential and proprietary property of Midtronics, Inc.
1. Summary
•The MDX ZIG EE RADIO is installed onto the CELLGUARD attery Sensor during manufacturing of
the sensor by Midtronics Inc. The MDX ZIG EE RADIO module is inside the product enclosure, and is
not accessible by the end user.
•The configuration and settings of the MDX ZIG EE RADIO module are preprogrammed during
manufacturing by Midtronics Inc and are not accessible to the end user
•CELLGUARD attery Sensor containing the internal MDX ZIG EE RADIO module is not installed by
the end user. The CELLGUARD attery Sensor shall only be installed by installers trained and
certified by Midtronics Inc with explicit approval by Midtronics Inc.
•The MDX ZIG EE RADIO module is only installed only in the products listed in the table below.
MDX ZIG EE RADIO module is installed only in the CELLGUARD attery Sensors in this Table
Sensor
Part
Number
Description PC A
Part Number
CGDS-02V PCBA, CELLGUARD DUAL 2V SENSOR GEN II + 198-000315
CGDS-04V PCBA, CELLGUARD DUAL 04V SENSOR GEN II + 198-000316
CGDS-12V PCBA, CELLGUARD DUAL 12V SENSOR GEN II + 198-000314
CGDS-16V PCBA, CELLGUARD DUAL 16V SENSOR GEN II + TBD
CGSS-02V PCBA, CELLGUARD SINGLE 2V SENSOR GEN II + TBD
CGSS-12V PCBA, CELLGUARD SINGLE 12V SENSOR GEN II + TBD
CGDH-02V PCBA, CELLGUARD DUAL HYBRID 2V SENSOR GEN II + 198-000336
CGDH-04V PCBA, CELLGUARD DUAL HYBRID 4V SENSOR GEN II + 198-000335
CGDH-06V PCBA, CELLGUARD DUAL HYBRID 6V SENSOR GEN II + 198-000334
CGDH-08V PCBA, CELLGUARD DUAL HYBRID 8V SENSOR GEN II + 198-000333
CGDH-12V PCBA, CELLGUARD DUAL HYBRID 12V SENSOR GEN II + 198-000332
CGDH-16V PCBA, CELLGUARD DUAL HYBRID 16V SENSOR GEN II + 198-000331
GEN II CELLGU RD Battery Sensor, Model: CGDS-12V

Doc No: TBD Page 4
The information contained herein is the confidential and proprietary property of Midtronics, Inc.
2. MDX ZIG EE RADIO Installation
The MDX ZIGBEE RADI module inside the CELLGUARD Battery Sensor shall not be accessed by
the end user. The radio module shall not be removed or installed. The radio module requires no
setup, configuring, or maintenance by the end user. The radio module inside the CELLGUARD
Battery Sensor should be invisible to the end user.
3. Technical Specifications of MDX ZIG EE RADIO Module
3.1 Description of MDX ZIG EE RADIO module
The MDX ZIGBEE RADI module is located on the PCB assembly of the Dual Sensor, and
enclosed in the CELLGUARD Battery Sensor case. The radio module is not accessible by the user.
MDX ZIGBEE RADIO Module

Doc No: TBD Page 5
The information contained herein is the confidential and proprietary property of Midtronics, Inc.
MDX ZIGBEE RADIO Module
MDX ZIGBEE RADIO Installed on PCBA
CELLGUARD Battery Sensor PCBA Inside Enclosure

Doc No: TBD Page 6
The information contained herein is the confidential and proprietary property of Midtronics, Inc.
3.2 MDX ZIG EE RADIO Module Specifications Table
Radio Specifications
Data Rate 250kbps
Supply Voltage
(Supplied by Dual Sensor) 3.3V
Operating requency ISM 2.4GHz
Operating Temperature 0⁰C to +65⁰C
Addressing Option PAN ID
Channels 12
Channel Separation 5MHz
Mode Direct Sequence
Spread Spectrum
Phase Shift Keying O-QPSK
3.3 Table of Allowable Channels
Channels Corres onding Frequency
3.4 MDX ZIG EE RADIO Module Antenna Specifications Table
Antenna Specifications
Type Chip
Configuration Permanent
requency Range
Minimum requency 2400MHz
requency Range
Maximum requency 2500MHz
Polarization Linear
Peak Gain 2dBi
Dimensions 6.7 x 6.7 x 1 mm
VSWR (~:1) 2:1

Doc No: TBD Page 7
The information contained herein is the confidential and proprietary property of Midtronics, Inc.
4. Agency Certifications for MDX ZIG EE RADIO
This product complies with CC OET Bulletin 65 & Industry Canada’s RSS-102 radiation exposure
limits set forth for an uncontrolled environment
This device complies with Part 15 of the CC Rules and Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) This device may not
cause harmful interference. and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Cet appareil est conforme à des règlements d'Industrie Canada exempts de licence standard
RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) Ce dispositif ne
doit pas causer d'interférences nuisibles, et (2) cet appareil doit accepter toute interférence
reçue, y compris les interférences pouvant entraîner un fonctionnement indésirable.
Pursuant to FCC 15.21 of the FCC rules, changes not expressly approved by Midtronics Inc.,
might cause harmful interference and void the FCC authorization to operate this product.
5. attery Sensor Installation
The end user does not install the CELLGUARD Battery Sensor containing the MDX ZIGBEE RADIO
module. CELLGUARD Battery Sensor installation shall only be performed by installers are trained and
explicitly certified by Midtronics. All installations shall be explicitly approved by Midtronics. If you are
a certified installer and require information about CELLGUARD Battery Sensor Installation, refer to
document CGFS-W-201 Gen 2 Dual Sensor Wiring Instructions r4 in its entirety.

Doc No: TBD Page 8
The information contained herein is the confidential and proprietary property of Midtronics, Inc.
CELLGUARD Battery Sensors Monitoring 12V UPS Batteries
6. Intended Use
The CELLGUARD Battery Sensors are installed via a wire harness on large batteries used for
Uninterruptable Power Supply Systems. The sensor measures various battery parameters and
communicates the data wirelessly to a Base Coordinator Unit. The data is then sent to
CELLTRAQ, Midtronics’ enterprise battery monitoring software, for interpretation and analysis.
CELLGUARD System Summary

Doc No: TBD Page 9
The information contained herein is the confidential and proprietary property of Midtronics, Inc.
7. Safety

Doc No: TBD Page 10
The information contained herein is the confidential and proprietary property of Midtronics, Inc.
8. Patents
9. Limited Warranty
10. Service
Table of contents